Jingying Wan

Jingying Wan

Auto-generated profile, based on publicly available information

Jingying Wan

College of Electrical and Information Engineering, Hunan University, Changsha, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2024 in IEEE Access
Verified
Journal Article
Open access
HYHaiying Yu
Haiying Yu
ZLZhongfeng Lu
Zhongfeng Lu
YLYuliang Liu
Yuliang Liu
YGYang Gao
Yang Gao
JWJingying Wan
Jingying Wan
In distribution networks with a high proportion of inverter-interfaced distributed generators (IIDGs), the fault ride-through control strategy of the inverter affects the output current of IIDGs, causing limited amplitude and time-varying phase. This hinders the effectiveness of traditional protection schemes in safeguarding active distribution networks. To address this issue, a fault protection concept involving "active harmonic injection of IIDGs, harmonic layer establishment of the distribution network, and feature difference construction of internal and external faults" is proposed in this paper. Based on this concept, initially, the amplitude characteristics of actively injected harmonics are examined for both active lines equipped with IIDG interfaces and passive lines lacking interfaced IIDG. Following this analysis, protection criteria are established, taking into account the discrepancies between the two types of branches during fault occurrences. To boost system security and complete the protection strategy, the impedance at various frequencies is used for backup protection, making protection process more reliable. Especially, the designed main protection scheme exploits harmonic current differences between adjacent lines, enabling protection with minimal communication bandwidth, balancing efficiency and effectiveness. The proposed protection scheme is validated through MATLAB/Simulink simulations, considering various scenarios such as different fault resistances, fault locations, connection of nonlinear loads, failure of main protection and disconnection of some IIDGs. These simulation results demonstrate the effectiveness of the proposed protection scheme.

25 February 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZSZhikang Shuai
Zhikang Shuai
LWLiping Wu
Liping Wu
LHLili He
Lili He
JWJingying Wan
Jingying Wan
WWWei Wang
Wei Wang
QXQianming Xu
Qianming Xu
Due to the high fault occurrence probability of submarine cable caused by extreme working environment, accurate fault detection and location is very essential for submarine DC power systems. While electrical faults are usually accompanied by the failures of optical fiber communication, resulting in the poor reliability of the existing methods based on cabled communication. Therefore, we propose a communication-free fault location method using multiple incipient current features. First, the fault modeling and current loop decoupling of submarine DC power systems are carried out to obtain the time domain description of fault line current. According to the varying trends and rates of incipient fault current with fault distance and fault resistance, multiple time domain features are utilized to reflect the fault distance meanwhile weaken the adversity of transition resistance. Then, the segmented mapping model between selected features and fault distance are established by using least squares support vector machine regression (LSSVR) algorithm. Via the integrated fault features and segmented location models, the proposed method can cover the fault location of whole line, and offers the advantages of fast speed and high accuracy. Finally, PSCAD simulation and hardware-in-loop (HIL) experiment results validate the effectiveness of the proposed method under various fault conditions.

3 June 2025 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
LHLili He
Lili He
QZQuan Zhou
Quan Zhou
XWXiangyang Wu
Xiangyang Wu
JWJingying Wan
Jingying Wan
WWWei Wang
Wei Wang
ZSZhikang Shuai
Zhikang Shuai
Due to the high incidence of faults in submarine cables, the rapid and accurate fault line detection is crucial for ensuring the safety and reliable operation of submarine MVDC power systems. In this paper, considering the fault response of shore station MMC, the transient and steady-state fault characteristics of meshed submarine MVDC power systems are analyzed. It reveals the differences in the direction and amplitude of high frequency superimposed currents (HFSCs) and low frequency superimposed currents (LFSCs) at both ends of the fault and non-fault lines. Then, by extracting transient energy from HFSC and monitoring changing trend of LFSC, signed binary state direction features of full frequency current are derived. These features are used to construct the protection criteria, which are robust against the change of fault scenario, fault starting speed and sampling frequency. Localized feature processing renders the protection accuracy immune to communication delay and synchronization error. Furthermore, the low bandwidth fault data exchange demand between line terminals is ensured by combining the fast submarine cabled communication and flexible space-ground-sea integrated network. Finally, simulation results on the modified North East Pacific Time-Integrated Undersea Networked Experiments (NEPTUNE) power system validate the effectiveness of the proposed scheme under various fault scenarios.