7 September 2023 in IEEE Journal of Biomedical and Health Informatics
Supervised deep-learning techniques with paired training datasets have been widely studied for low-dose computed tomography (LDCT) imaging with excellent performance. However, the paired training datasets are usually difficult to obtain in clinical routine, which restricts the wide adoption of supervised deep-learning techniques in clinical practices. To address this issue, a general idea is to construct a pseudo paired training dataset based on the widely available unpaired data, after which, supervised deep-learning techniques can be adopted for improving the LDCT imaging performance by training on the pseudo paired training dataset. However, due to the complexity of noise properties in CT imaging, the LDCT data are difficult to generate in order to construct the pseudo paired training dataset. In this paper, we propose a simple yet effective cross-domain unpaired learning framework for pseudo LDCT data generation and LDCT image reconstruction, which is denoted as CrossDuL. Specifically, a dedicated pseudo LDCT sinogram generative module is constructed based on a data-dependent noise model in the sinogram domain, and then instead of in the sinogram domain, a pseudo paired dataset is constructed in the image domain to train an LDCT image restoration module. To validate the effectiveness of the proposed framework, clinical datasets are adopted. Experimental results demonstrate that the CrossDuL framework can obtain promising LDCT imaging performance in both quantitative and qualitative measurements.
5 February 2023 in Advanced Sensor Research
Cardiac arrest is a fatal and urgent disease in humans. A high‐quality electrocardiogram (ECG) has a positive guide to the success of defibrillation and resuscitation. However, because of artificial motion interference and ambient noise, reliable ECG signals can be obtained only during chest compression (CC) pauses. To address this issue, the adaptive recursive least squares (RLS) denoising approach is proposed. First, the ECG signals of porcine are divided into three groups: CC, without CC, and both with and without CC. Then, five Gaussian noises with different signals‐to‐noise ratios (SNR) and five noises with different distribution types are added, respectively. Furthermore, RLS is compared with six other different denoising approaches. Experimental results demonstrate significant differences between RLS and the other six algorithms in main metrics. SNR and related factors are larger, while the root mean square error is smaller. In conclusion, RLS can significantly eliminate many types of ambient noise, and improve the quality of ECG signals during cardiopulmonary resuscitation.