We use first-principles density functional theory and ab initio molecular orbital theory to study the chiral transition process of the serine molecule and explore the roles of water, hydroxyl radical and hydroxide ion as catalysis during the interconversion process. The two most plausible chiral transition pathways of isolated serine are identified, in which α-hydrogen is transferred using the amino N atom as a bridge rather than the carbonyl O atom. These two chiral transition mechanisms involve the transformation of chiral enantiomers; in other words, they are serine enantiomerization. Two proton transfer steps with high energy barriers of ∼58.0 and 37.0 kcal mol−1 are the rate-limiting steps. The calculations show that water can effectively catalyze the chiral transition by facilitating efficient proton transport, and the highest energy barriers are ∼26.4 and 4.8 kcal mol−1. The calculations also predict that hydroxyl radical can further lower the energy barriers of the chiral transition to approximately 12.6 and 5.3 kcal mol−1 by facilitating proton transfer. In contrast, hydroxyl radical is more likely to damage serine, and the damage is difficult to repair. Finally, hydroxide ion can further reduce the barriers to chiral transition to approximately 5.5 and 4.5 kcal mol−1 by facilitating proton transfer. As far as we know, this is the first time that these important roles of water, hydroxyl radical and hydroxide ion in serine chiral transition have been demonstrated. The findings provide new insights into the mechanism of serine enantiomerization at the atomic level. Meanwhile, the results show that hydroxyl radical can damage serine, and the damage is difficult to repair.
Nonlinear crystal frequency conversion imaging with direct detection by silicon-based detectors is an effective way to break through the limitations for existing near-infrared (NIR) detectors with expensive cost and high noise. In this paper, a broadband NIR detector imaging scheme based on the principle of nonlinear crystal frequency conversion (NCFCP) was proposed. A thin film of nonlinear crystal frequency conversion material (NCFCM) combined with a silicon-based detector was used to form a broadband NIR detector. The theoretically investigated energy transfer function was used as a guidance for experiment. Meanwhile, the relationship between the imaging effect and the energy transfer of the NCFCP-based compact broadband NIR detector in the NIR band was measured experimentally. The accuracy of the theoretical study had been verified by the measured transfer results.
Frequency conversion imaging technology can provide an effective way for infrared detection against the limitations of conventional infrared detectors, such as expense and cooling requirements, but the converted luminescence intensity of frequency conversion materials limits the application of this technology. In this paper, a cascade material (CM) fusion method is proposed to improve the conversion luminous intensity and thus enhance the frequency conversion imaging effect at 1550 nm near infrared (NIR) excitation. First, we derived from the energy level transition mechanism of CM that the CM fusion method can achieve three excitations of substrate materials (SMs). It can improve the conversion luminescence intensity of SM in CM. Then, we experimentally prepared CM and SM films and simultaneously measured the frequency conversion imaging effect of the two films at 1550 nm NIR excitation. It was found that the weight ratio of doped material (DM) to SM affects the imaging enhancement of CM films. Therefore, we compared the imaging grayscale value intensity of CM films with different weight ratios under the same detection conditions. Finally, it was concluded that the best enhancement of frequency conversion imaging was achieved with a DM to SM weight ratio of 0.25 for this mechanism. The enhancement was about 3.11 times compared to SM films.