Objectives. This study sought to assess the safety and long-term efficacy of drug-coated balloons (DCB) following aggressive intracoronary image-guided rotational atherectomy (iRA) for severe coronary artery calcification (CAC), and to compare this strategy with new generation drug-eluting stents (nDES) following iRA. Background. Ischemic events following the treatment of CAC is still relatively high. Thus, more innovative strategies are required. Methods. We evaluated 123 consecutive patients (166 lesions) with de novo CAC undergoing an iRA (burr size; 0.7 of the mean reference diameter by intracoronary imaging) followed by DCB (DCB-iRA; 54 patients, 68 lesions) or nDES (nDES-iRA; 69 patients, 98 lesions). Follow-up angiography was obtained at > 6 months. Results. The target vessels (right coronary and circumflex), bifurcation (67.6% versus 47.9%), reference diameter (2.28mm versus 2.49mm), and lesion length (11.89mm versus 18.78mm) were significantly different between the two groups. The median follow-up was 732 days. TLR and TVR in DCB-iRA and nDES-iRA at 3 years were similar: 15.6% versus 16.3% (P=0.99) and 15.6% versus 23.3% (P=0.38). In 41 well-matched lesion pairs after propensity score analysis, the cumulative incidence of TLR and TVR in DCB-iRA and nDES-iRA at 3 years was 12.9% versus 16.3% (P=0.70) and 12.9% versus 26.1% (P=0.17), respectively. On QCA analysis, although the acute gain was smaller in DCB-iRA (0.85 mm versus 1.53 mm, P<0.001), the minimum lumen diameter at follow-up was similar (1.69 mm versus 1.87 mm, P=0.29). The late lumen loss was lower (0.09 mm versus 0.52 mm, P=0.009) in DCB-iRA. Conclusions. DCB-iRA is feasible for CAC.
Robotic remote-control technologies have a wide field of applications. Bilateral control is a type of remote-control technique. Most of the existing bilateral control techniques require complicated force transmission mechanisms in the master systems. Therefore, operators feel discomfort due to a sense of restraint by the exoskeleton-type robot arms.We attempted to solve this problem by incorporating functional electrical stimulation into the master system. In this study, bilateral control was proposed between a human and a three-joint robot with three degrees of freedom using functional electrical stimulation for shoulder and elbow joints. The experiment consisted of extracting a block of Jenga using the slave robot. The proposed method was compared to unilateral control in which the master moves freely without feedback to the master.
The current methods to generate robot actions for automation in significantly different environments have limitations. This paper proposes a new method that matches the impedance of two prerecorded action data with the current environmental impedance to generate highly adaptable actions. This method recalculates the command values for the position and force based on the current impedance to improve reproducibility in different environments. Experiments conducted under conditions of extreme action impedance, such as position and force control, confirmed the superiority of the proposed method over existing motion reproduction system. The advantages of this method include the use of only two sets of motion data, significantly reducing the burden of data acquisition compared with machine-learning-based methods, and eliminating concerns about stability by using existing stable control systems. This study contributes to improving the environmental adaptability of robots while simplifying the action generation method.
Insufficient thrust density is a critical issue in a solid-state electro-aerodynamic propulsion system (SSEP) during vertical takeoff and landing (VTOL) drones. Therefore, this study proposes the use of booster electrodes designed to enhance ion generation. To evaluate its performance, numerical simulations were conducted using a two-dimensional, three-species plasma fluid model. The results were experimentally validated, demonstrating that booster electrodes enhance the thrust density of SSEP by ∼4.46 times at 15 kV, 2.22 times at 20 kV, and 1.84 times at 25 kV when compared with the results of the configuration without the booster electrode. This study encourages the practical applications of VTOL drones by demonstrating the improvement in thrust density with booster electrodes through both numerical analysis and experiments.
30 December 2025 in IEEE Transactions on Industrial Electronics
The motion reproduction system (MRS) transfers human dexterous motion skills to robots. Compared with other machine learning-based methods, it has an advantage in terms of the number of data points and hyperparameters. However, it may fail when the actual object of motion differs from that of acquired human motion. Conventional studies consider human stiffness, which characterizes the intention of human motion. Although they performed better than the original MRS with variable objects, they estimated human impedance using linear interpolation. Linear interpolation is insufficient for generating novel, human-like motions that are nonlinear and time-variant. In this article, more sophisticated motions were generated by fitting the relationship between environmental stiffness and position, velocity, and force nonlinearly using Gaussian process regression, which requires a smaller amount of data compared to machine learning-based schemes. Through experiments, the data number and error reduction between the true human motion and actual motion were confirmed by comparing the original and conventional MRS and the imitation learning. Therefore, the proposed method can generate motion for variable objects more precisely with a small amount of human motion data.
1 August 2026 in IEEE Transactions on Medical Robotics and Bionics