1 May 2025 in Journal of Instrumentation
With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems capable of operation at cryogenic temperatures in order to achieve the low vibration levels required for operation of sensitive equipment like cryogenic detectors or quantum devices. As part of the NUCLEUS experiment, a cryogenic spring pendulum has been engineered to effectively isolate pulse tube vibrations by establishing an autonomous frame of reference for the experimental volume, while sustaining temperatures below 10 mK. Attaining attenuation of up to two orders of magnitude within the region of interest of the NUCLEUS cryogenic detectors, we achieved displacement RMS values in the order of 1 nm in the axial direction and 100 pm radially, thereby reducing vibrations below typical environmental levels. Our successful detector operation across multiple cooldown cycles demonstrated negligible sensitivity to pulse tube induced vibrations, culminating in the achievement of an ultra-low (6.22 ± 0.07) eV baseline resolution on a gram-scale CaWO4 cryogenic calorimeter during continuous pulse tube operation over the course of several weeks.
28 October 2025 in Physical Review D
The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos on CaWO 4 targets in the fully coherent regime, using gram-scale cryogenic calorimeters. The experimental apparatus will be installed at the Chooz nuclear power plant in France, in the vicinity of two 4.25 GW th reactor cores. This work presents results from the commissioning of an essential version of the experiment at the shallow Underground Laboratory of the Technical University of Munich. For the first time, two cryogenic target detectors were tested alongside active and passive shielding systems. Over a period of two months, all detector subsystems were operated with stable performance. Background measurements were conducted, providing important benchmarks for the modeling of background sources at the reactor site. Finally, we present ongoing efforts to upgrade the detector systems in preparation for a technical run at Chooz in 2026, and highlight the remaining challenges to achieving neutrino detection.
22 October 2025 in The European Physical Journal C
The Crab (Calibrated nuclear Recoils for Accurate Bolometry) project aims to precisely characterize the response of cryogenic detectors to sub-keV nuclear recoils of direct interest for coherent neutrino-nucleus scattering and dark matter search experiments. The Crab method relies on the radiative capture of thermal neutrons in the target detector, resulting in a nuclear recoil with a well-defined energy. We present a new experimental setup installed at the TRIGA Mark-II reactor at Atominstitut (Vienna), providing a low intensity beam of thermal neutrons sent to the target cryogenic detector mounted inside a wet dilution refrigerator Kelvinox 100. After the presentation of all components of the setup we report the analysis of first commissioning data with CaWO $$_{4}$$ detectors of the Nucleus experiment. They show stable operation of the cryostat and detectors on a week-scale. Due to an energy resolution currently limited to 20 eV we use neutron beam induced events at high energy, in the 10 to 100 keV range, to demonstrate the excellent agreement between the data and simulation and the accurate understanding of external background. Thanks to these data we also propose an updated decay scheme of the low-lying excited states of $$^{187}$$ W. Finally, we present the first evidence of neutron-capture induced coincidences between BaF $$_2$$ $$\gamma $$ -detectors installed around the dewar and the inner cryogenic detector. These promising results pave the way for an extensive physics program with various detector materials, like CaWO $$_{4}$$ , Al $$_{2}$$ O $$_{3}$$ , Ge and Si.
6 September 2025 in Journal of Low Temperature Physics
Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100 eV is crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a $$^{55}$$ Fe source to irradiate a two-staged target arrangement, emitting characteristic emission lines from 677 eV to 6.5 keV. We demonstrate the potential of this new XRF source to calibrate a 0.75 g CaWO $$_4$$ crystal of the NUCLEUS and CRAB experiments. Additionally, we introduce CryoLab, an advanced analysis tool for cryogenic detector data, featuring robust methods for data processing, calibration, and high-level analysis, implemented in MATLAB and HDF5. We also present a phenomenological model for energy resolution, which incorporates statistical contributions, systematic effects, and baseline noise, enabling a novel approach to evaluating athermal phonon collection efficiency in macro-calorimeters based on transition edge sensors (TES).
16 January 2026 in The European Physical Journal C
NUCLEUS is a cryogenic detection experiment which aims to measure Coherent Elastic Neutrino–Nucleus Scattering (CE $$\nu $$ NS) and to search for new physics at the Chooz nuclear power plant in France. This article reports on the prediction of particle-induced backgrounds, especially focusing on the sub-keV energy range, which is a poorly known region where most of the CE $$\nu $$ NS signal from reactor antineutrinos is expected. Together with measurements of the environmental background radiations at the experimental site, extensive Monte Carlo simulations based on the Geant4 package were run both to optimize the experimental setup for background reduction and to estimate the residual rates arising from different contributions such as cosmic ray-induced radiations, environmental gammas and material radioactivity. The NUCLEUS experimental setup is predicted to achieve a total rejection power of more than two orders of magnitude, leaving a residual background component which is strongly dominated by cosmic ray-induced neutrons. In the CE $$\nu $$ NS signal region of interest between 10 and 100 eV, a total particle background rate of $$\sim $$ 250 d −1 kg −1 keV −1 is expected in the CaWO 4 target detectors. This corresponds to a signal-to-background ratio $$\gtrsim $$ 1, and therefore meets the required specifications in terms of particle background rejection for the detection of reactor antineutrinos through CE $$\nu $$ NS.
18 July 2026 in The European Physical Journal C
The NUCLEUS experiment aims to detect coherent elastic neutrino–nucleus scattering of reactor antineutrinos using low-threshold, gram-scale cryogenic calorimeters. Similar to other low-threshold experiments, NUCLEUS observes a sharp rise in the event rate below a few hundred eV, referred to as the low energy excess (LEE), whose origin remains yet unidentified. Building on results from the NUCLEUS testing and commissioning at the Technical University of Munich and from previous characterization campaigns, we present a comprehensive study of the background rate measured with a sapphire detector equipped with two transition-edge sensors under various experimental conditions. We find no evidence for a dependence of the LEE rate on the particle background level, whereas the results indicate that slower cooling-down procedures lead to lower initial LEE rates. The behavior of the LEE rate during the same cooldown is comparable across the measurements and is best described by a power law with a common exponent across datasets of $$(-0.59\pm 0.06)$$ , when time is expressed from the moment the detector reaches the 4 K temperature. These findings provide valuable guidance for future LEE mitigation strategies in the NUCLEUS experiment.