R. A. Lerche

R. A. Lerche

Auto-generated profile, based on publicly available information

R. A. Lerche

Lawrence Livermore National Laboratory, P.O. Box 808, Livermore, California 94551, USA

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2001 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
TMThomas J. Murphy
Thomas J. Murphy
CBCris W. Barnes
Cris W. Barnes
RBR. R. Berggren
R. R. Berggren
PBP. Bradley
P. Bradley
SCS. E. Caldwell
S. E. Caldwell
RFR. K. Fisher
R. K. Fisher
The National Ignition Facility (NIF), currently under construction at the Lawrence Livermore National Laboratory, will provide unprecedented opportunities for the use of nuclear diagnostics in inertial confinement fusion experiments. The completed facility will provide 2 MJ of laser energy for driving targets, compared to the approximately 40 kJ that was available on Nova and the approximately 30 kJ available on Omega. Ignited NIF targets are anticipated to produce up to 1019 DT neutrons. In addition to a basic set of nuclear diagnostics based on previous experience, these higher NIF yields are expected to allow innovative nuclear diagnostic techniques to be utilized, such as neutron imaging, recoil proton techniques, and gamma-ray-based reaction history measurements.

1 October 2010 in Review of Scientific Instruments
Verified
Journal Article
Closed access
RLR. A. Lerche
R. A. Lerche
VGV. Yu. Glebov
V. Yu. Glebov
MMM. J. Moran
M. J. Moran
JMJ. M. McNaney
J. M. McNaney
JKJ. D. Kilkenny
J. D. Kilkenny
CHC. J. Horsfield
C. J. Horsfield
The first 3 of 18 neutron time-of-flight (nTOF) channels have been installed at the National Ignition Facility (NIF). The role of these detectors includes yield, temperature, and bang time measurements. This article focuses on nTOF data analysis and quality of results obtained for the first set of experiments to use all 192 NIF beams. Targets produced up to 2×1010 2.45 MeV neutrons for initial testing of the nTOF detectors. Differences in neutron scattering at the OMEGA laser facility where the detectors were calibrated and at NIF result in different response functions at the two facilities. Monte Carlo modeling shows this difference. The nTOF performance on these early experiments indicates that the nTOF system with its full complement of detectors should perform well in future measurements of yield, temperature, and bang time.

1 March 2003 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
NIN. Izumi
N. Izumi
RLR. A. Lerche
R. A. Lerche
TPT. W. Phillips
T. W. Phillips
GSG. J. Schmid
G. J. Schmid
MMM. J. Moran
M. J. Moran
TST. C. Sangster
T. C. Sangster
A detector for fuel areal density measurements in inertial confinement fusion capsules has been designed. Observation of neutrons scattered in an imploded deuterium capsule (0.27–0.6 MeV) is a promising method for areal density measurements in the National Ignition Facility DD surrogate capsules. In order to detect scattered neutrons, we need to (1) suppress interference due to the strong direct neutron burst and (2) suppress the background produced by neutrons scattering on nontarget material (mainly from the target chamber). In our detector system, we suppress direct neutrons by gating the detector. We suppress the nontarget background neutrons by placing the detector outside the target chamber and limiting the view of the detector with collimators. In addition, we are developing a lithium-glass scintillation-fiber detector (LG-SCIFI) to detect the scattered neutrons. The LG-SCIFI will work as a multichannel scintillator array. The scintillation signal will be amplified by a microchannel plate image intensifier, which is gated to accept signals only in a specific time-of-flight window for the scattered neutrons. The gated scintillation image will be recorded by a charge-coupled device. Since the detector is segmented, neutron detection events will be clearly identified as bright spots in the gated image.

1 October 2010 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
RLR. A. Lerche
R. A. Lerche
BGB. P. Golick
B. P. Golick
JHJ. P. Holder
J. P. Holder
DKD. H. Kalantar
D. H. Kalantar
Moderately priced oscilloscopes available for the NIF power sensors and target diagnostics have 6 GHz bandwidths at 20–25 Gsamples/s (40 ps sample spacing). Some NIF experiments require cross timing between instruments be determined with accuracy better than 30 ps. A simple analysis algorithm for Gaussian-like pulses such as the 100-ps-wide NIF timing fiducial can achieve single-event cross-timing precision of 1 ps (1/50 of the sample spacing). The midpoint-timing algorithm is presented along with simulations that show why the technique produces good timing results. Optimum pulse width is found to be ∼2.5 times the sample spacing. Experimental measurements demonstrate use of the technique and highlight the conditions needed to obtain optimum timing performance.