Teruyuki Kohno

Teruyuki Kohno

Auto-generated profile, based on publicly available information

Teruyuki Kohno

Department of Diabetes, Endocrinology and Metabolism School of Medicine, Fukushima Medical University, Fukushima City, Japan

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2016 in Journal of Medical Case Reports
Verified
Journal Article
Open access
PDF file
HHhiroyuki hirai
hiroyuki hirai
EOEmi Ogata
Emi Ogata
NKNobuyuki Kikuchi
Nobuyuki Kikuchi
TKTeruyuki Kohno
Teruyuki Kohno
NMNoritaka Machii
Noritaka Machii
HSHiroaki Satoh
Hiroaki Satoh
Liraglutide is one of the glucagon-like peptide-1 analogs; there are only a few reports of liraglutide being used for the treatment of insulin allergy. Furthermore, anti-insulin immunoglobulin G antibodies are occasionally detected in patients with diabetes. Hence, we report a case in which switching to liraglutide therapy ameliorated both the symptoms of insulin allergy with hypereosinophilia and the characteristics of insulin antibodies in a patient with type 2 diabetes mellitus. We present the case of a 70-year-old Japanese man with type 2 diabetes who developed insulin allergy with hypereosinophilia. Anti-insulin antibodies, high glycated hemoglobin levels (approximately 12 %), and high serum insulin levels were detected. Because a change in his insulin treatment was inefficient, treatment with liraglutide to protect residual insulin secretion was started, resulting in improvements in his insulin allergy, serum glycated hemoglobin, insulin, and eosinophil levels. Scatchard plots revealed decreased binding capacity and increased affinity constant for high affinity sites of anti-insulin antibodies. Liraglutide might be useful for treating insulin allergy and anti-insulin antibodies in patients with type 2 diabetes.

2 May 2024 in Journal of Computer Assisted Tomography
Verified
Journal Article
Closed access
JHJunko Hara
Junko Hara
SIShiro Ishii
Shiro Ishii
HTHayato Tanabe
Hayato Tanabe
RYRyo Yamakuni
Ryo Yamakuni
HSHiroki Suenaga
Hiroki Suenaga
HIHiroshi Ito
Hiroshi Ito
Objective: The aim of the study is to reveal the respiratory displacement of the right adrenal vein (RAV) to predict the exact location of the RAV during adrenal venous sampling (AVS). Methods: Computed tomography (CT) scans obtained 45 seconds (breath-hold at inhalation) and 70 seconds (breath-hold at exhalation) after contrast material injection were compared to venograms of the RAV of patients with primary aldosteronism who underwent AVS between January 2016 and December 2020. The craniocaudal distance between the center of the Th11/12 disc and the RAV orifice was measured; the craniocaudal location of the RAV orifice was also specified relative to vertebral bodies and intervertebral discs on inspiratory phase CT (In-CT), expiratory phase CT (Ex-CT), and catheter venography. The transverse and vertical angles of the RAV and the position of the RAV orifice on the inferior vena cava (IVC) circumference were measured on In-CT and Ex-CT. Results: In total, 51 patients (30 males, 21 females; mean age, 54.9 ± 11.1 years) were included. Craniocaudal distances between the center of the Th11/12 disc and RAV orifice were significantly different among the following 3 acquisitions: catheter venography versus In-CT (15.2 ± 8.4 mm); venography versus Ex-CT (5.6 ± 4.1 mm); and In-CT versus Ex-CT (19.6 ± 8.0 mm) (all, P < 0.001). The craniocaudal location of the RAV orifice on venography was significantly closer to that on Ex-CT than on In-CT (P < 0.001); measurements using venograms compared with In-CT and Ex-CT scans were within 1 level difference in 18 (35.3%) and 47 (92.2%) patients, respectively (P < 0.001). The vertical angle of the RAV was significantly more likely to be smaller on In-CT than on Ex-CT (P < 0.001). Conclusions: RAV locations and angles change with respiratory motion. It is crucial to consider the respiratory phase of CT because it can enable a more accurate prediction of the location of the RAV during AVS.