Jianxiao Zou

Jianxiao Zou

Auto-generated profile, based on publicly available information

Jianxiao Zou

University of Electronic Science and Technology of China

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 October 2019 in IEEE Transactions on Cybernetics
Verified
Journal Article
Closed access
XYXinbo Yu
Xinbo Yu
WHWei He
Wei He
YLYanan Li
Yanan Li
CXChengqian Xue
Chengqian Xue
JLJianqiang Li
Jianqiang Li
Chenguang YangChenguang Yang
Chenguang Yang
This article proposes a Bayesian method to acquire the estimation of human impedance and motion intention in a human-robot collaborative task. Combining with the prior knowledge of human stiffness, estimated stiffness obeying Gaussian distribution is obtained by Bayesian estimation, and human motion intention can be also estimated. An adaptive impedance control strategy is employed to track a target impedance model and neural networks are used to compensate for uncertainties in robotic dynamics. Comparative simulation results are carried out to verify the effectiveness of estimation method and emphasize the advantages of the proposed control strategy. The experiment, performed on Baxter robot platform, illustrates a good system performance.

25 November 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
CXChuan Xie
Chuan Xie
KLKai Li
Kai Li
JZJianxiao Zou
Jianxiao Zou
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
For LCL-type grid-connected inverters, inverter-side current, grid-side current, capacitor current and voltage are four commonly used variables in the control serving as different roles, such as control objective, active damping, synchronization, etc. This article builds a general admittance model, in which the total output admittance is decomposed into four paralleled subadmittance corresponding to the above four variables in the control law, to facilitate the passivity-based stability assessment and controller parameter optimization for different control objectives and schemes. Based on the passivity analysis, an appropriate combination scheme of subadmittance and a simple unified analytical controller parameter design method are proposed to obtain a passive output admittance from 0 Hz up to Nyquist frequency for either inverter-side or grid-side current control. Therefore, it can not only ensure the stable operation of LCL-type inverters regardless of grid impedance (either inductive or capacitive) but also avoid the conventional design constraints of an LCL filter, i.e., f r <; or > f s /6 is required for the single-loop inverter-side or the grid-side current control. Finally, experiments verify the theoretical results.

3 February 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
CXChuan Xie
Chuan Xie
KLKai Li
Kai Li
JZJianxiao Zou
Jianxiao Zou
Dong LiuDong Liu
Dong Liu
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
The frequency-domain passivity theory offers an effective way to assess the stability of inverters connecting to complex grid conditions, e.g., inductive grid, capacitive grid, and system comprising multiple inverters. In this article, an admittance model for the grid-side current-controlled LCL-type inverter with capacitor voltage feedforward active damping (CVF-AD) is built to facilitate the passivity-based stability assessment and controller parameter design. Especially, it is found that if the antiresonance frequency of the inverter-side inductor and the filter capacitor is designed in a certain region, i.e., (0.66f c + 0.034f 8 , 0.22f 8 ), all frequencies' passive output admittance of the inverter can be achieved via a modified CVF-AD scheme with simple digital implementation. Thanks to the proposed methods, the inverter can be connected to the grid regardless of the grid impedance, which means a robust plug-and-play functionality suitable for microgrid applications. In addition, the controller parameters are analytically designed; time-consuming iterations are, hence, avoided. The allowable tolerance of power circuit parameters for a valid controller parameter design is as high as 64% or more. The validity of the theoretical analysis and effectiveness of the proposed method are verified by using experimental results on a laboratory prototype.

1 January 2022 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
YZYun Zhu
Yun Zhu
JZJianxiao Zou
Jianxiao Zou
SLShuai Li
Shuai Li
CPChao Peng
Chao Peng

6 November 2018 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
XWXiaodong Wang
Xiaodong Wang
JZJianxiao Zou
Jianxiao Zou
JZJiancheng Zhao
Jiancheng Zhao
CXChuan Xie
Chuan Xie
KLKai Li
Kai Li
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero

7 May 2018 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
CXChuan Xie
Chuan Xie
XZXin Zhao
Xin Zhao
KLKai Li
Kai Li
JZJianxiao Zou
Jianxiao Zou
Josep M. GuerreroJosep M. Guerrero
Josep M. Guerrero
Resonant controllers (RSCs) are widely adopted for controlling power converters since they can track AC signals of both positive and negative sequences without steady-state error. However, the performance of RSCs has not been fully exploited due to the improper phase compensation angle and insufficient controller gain. In this paper, a novel controller parameters design method, which is based on the system error transfer function, is proposed to further explore the potential high performance of RSCs. Comparing with the conventional methods, more appropriate phase compensation angles can be obtained, which means that the stable region of the controller gain is extended. Since the proposed RSCs design method is able to maximize the controller gain, the controller sensitivity to system frequency variations can be decreased and the system response speed can be improved. The RSCs tuning procedure is given in detail, and comparative experiments between the proposed method and the conventional method are performed to validate the superiority of the proposed method.