The 3-year accelerated aging study of the SAVY-4000 O-ring detailed in our previous Lifetime Extension Report showed very little evidence of significant degradation to samples subjected to aggressive elevated temperature and radiation conditions. Whole container thermal aging studies followed by helium leakage testing and compression set measurements were used to establish a failure criterion estimate for O-ring compression set of ≥ 65 %, which led to an O-ring lifetime estimate of greater than 65 years at 80°C. Herein, we describe a statistical model of the 3-year accelerated aging study and present additional results gathered in FY17 that further support the lifetime extension of the O-ring to 40 years at 80°C. Because we are choosing an extremely conservative lifetime value (40 years) compared to the aging study results (>65 years), the O-ring lifetime could be extended further, especially if supported by surveillance results collected over the years to come.
Surveillance of vented, stainless-steel Hagan and SAVY-4000 storage containers with some plutonium materials has revealed evidence of corrosion inside the container. There are ~3000 items stored in Hagan containers and ~600 items currently stored in SAVY-4000 containers at TA -55. The Hagan is made of 304L steel, while the SAVY-4000 is made of 316L and should be less susceptible to corrosion. Given the relatively thin body wall of these containers (nominally 0.762 millimeters), it is essential to understand the effects of corrosion on the lifetime of the containers to ensure worker safety. Studies are being conducted on both container types to determine the relative susceptibility of the two containers to corrosion. This paper describes the potential cause of corrosion, the extent of corrosion, and types of corrosion observed, along with the results of accelerated aging experiments. The combined results of the surveillance and lifetime extension studies establish a technical basis for extending the design life of the stainless steel components of the SAVY-4000 container from 5 years to 15 years.
The Department of Energy (DOE) issued DOE M 441.1-1, Nuclear Material Packaging Manual, to protect workers who handle nuclear material from exposure due to loss of containment of stored materials [1]. Currently, the bag-out bags that are used to move material from a glovebox to a long-term storage container are made of a plasticized polyvinyl chloride (PVC) material formed into a bag. In 2015, corrosion was identified during the surveillance of Hagan and SAVY-4000 containers [2]. The corrosion that was identified in storage containers has been attributed to HCl gas generation from radiolytic and thermal degradation of the PVC bag-out bag material [3,4].