Qing Xie

Qing Xie

Auto-generated profile, based on publicly available information

Qing Xie

GSK, Collegeville, Pennsylvania

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2010 in Solid State Ionics
Verified
Journal Article
Closed access
DZDongEn Zhang
DongEn Zhang
QXQing Xie
Qing Xie
ACAiMei Chen
AiMei Chen
MWMingYan Wang
MingYan Wang
SLShanZhong Li
ShanZhong Li
ZTZhiWei Tong
ZhiWei Tong

16 August 2023 in Cancer Research Communications
Verified
Journal Article
Open access
PDF file
SYSapna Yadavilli
Sapna Yadavilli
JWJeremy D. Waight
Jeremy D. Waight
SBSara Brett
Sara Brett
MBMeixia Bi
Meixia Bi
TZTianqian Zhang
Tianqian Zhang
MBMarc Ballas
Marc Ballas
In recent years, there has been considerable interest in mAb-based induction of costimulatory receptor signaling as an approach to combat cancer. However, promising nonclinical data have yet to translate to a meaningful clinical benefit. Inducible T-cell costimulator (ICOS) is a costimulatory receptor important for immune responses. Using a novel clinical-stage anti-ICOS immunoglobulin G4 mAb (feladilimab), which induces but does not deplete ICOS+ T cells and their rodent analogs, we provide an end-to-end evaluation of the antitumor potential of antibody-mediated ICOS costimulation alone and in combination with programmed cell death protein 1 (PD-1) blockade. We demonstrate, consistently, that ICOS is expressed in a range of cancers, and its induction can stimulate growth of antitumor reactive T cells. Furthermore, feladilimab, alone and with a PD-1 inhibitor, induced antitumor activity in mouse and humanized tumor models. In addition to nonclinical evaluation, we present three patient case studies from a first-time-in-human, phase I, open-label, dose-escalation and dose-expansion clinical trial (INDUCE-1; ClinicalTrials.gov: NCT02723955), evaluating feladilimab alone and in combination with pembrolizumab in patients with advanced solid tumors. Preliminary data showing clinical benefit in patients with cancer treated with feladilimab alone or in combination with pembrolizumab was reported previously; with example cases described here. Additional work is needed to further validate the translation to the clinic, which includes identifying select patient populations that will benefit from this therapeutic approach, and randomized data with survival endpoints to illustrate its potential, similar to that shown with CTLA-4 and PD-1 blocking antibodies. Significance: Stimulation of the T-cell activation marker ICOS with the anti-ICOS agonist mAb feladilimab, alone and in combination with PD-1 inhibition, induces antitumor activity across nonclinical models as well as select patients with advanced solid tumors.

1 January 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
YLYaran Li
Yaran Li
QXQing Xie
Qing Xie
ZCZhiqiang Chen
Zhiqiang Chen
QXQiuqi Xin
Qiuqi Xin
XWXin Wang
Xin Wang
YDYongkun Ding
Yongkun Ding
Direct intensity calibration of X-ray grazing-incidence microscopes is urgently needed in quantitative studies of X-ray emission from laser plasma sources in inertial confinement fusion. The existing calibration methods for single reflecting mirrors, crystals, gratings, filters, and X-ray detectors are not applicable for such X-ray microscopes due to the specific optical structure and the restrictions of object-image relation. This article presents a reliable and efficient method that can be performed using a divergent X-ray source and an energy dispersive Si-PIN (silicon positive-intrinsic-negative) detector in an ordinary X-ray laboratory. The transmission theory of X-ray flux in imaging diagnostics is introduced, and the quantities to be measured are defined. The calibration method is verified by a W/Si multilayer-coated Kirkpatrick-Baez microscope with a field of view of ∼95 μm at 17.48 keV. The mirror reflectance curve in the 1D coordinate is drawn with a peak value of 20.9% and an uncertainty of ∼6.0%.

1 September 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
KRKuan Ren
Kuan Ren
ZCZhurong Cao
Zhurong Cao
JDJianjun Dong
Jianjun Dong
BMBaozhong Mu
Baozhong Mu
QXQing Xie
Qing Xie
SJShaoen Jiang
Shaoen Jiang
High-space-resolving information of hotspot electron temperature is a foundation for further research on physical processes of implosion in inertial confinement fusion. This work proposed a novel high-space-resolving electron temperature detector, which is based on the bremsstrahlung radiation mechanism of the implosion hotspot and uses two-channel Kirkpatrick–Baez microscopes. In this novel detector, an optical quasi-coaxis method was used to eliminate the strong impact of the view field difference on the high space resolution and correctness of the electron temperature diagnosis, and a compound KB microscope method was proposed to reduce the number of spherical reflectors and save space.

16 August 2023
Verified
Other
Open access
PDF file
SYSapna Yadavilli
Sapna Yadavilli
JWJeremy D. Waight
Jeremy D. Waight
SBSara Brett
Sara Brett
MBMeixia Bi
Meixia Bi
TZTianqian Zhang
Tianqian Zhang
MBMarc Ballas
Marc Ballas
Clinical case study of feladilimab monotherapy.