Total Hip Arthroplasty (THA) is one of the surgical procedures carried out satisfactorily in procedures for osteoarthritis and trauma lesions. ATC surgery reduces pain and improves the quality of life of young patients. Therefore, it is of great importance to improve the properties of hip implants, since current implants do not match their lifespan with the life expectancy of a young patient. This is because the solid prostheses that currently exist have a higher Young's modulus, and therefore are too rigid compared to the bone tissue. On the other hand, the cyclic and continuous loads to which the hip joint is subjected in daily activities, can cause loosening and consequent implant loss The present work proposes an implant manufactured with a porous lattice structure, which aims to reduce stiffness, allow bone growth and a more effective mechanical load transfer. Three computational models subjected to static charges were evaluated and compared: 1) healthy femur, 2) implanted femur with a commercial prosthesis, and 3) implanted femur with a prosthesis with lattice structure. For the computational analysis it was decided to perform a static analysis of a person standing on the left foot; a load equivalent to the body weight was applied on the head of the femur, balancing the reaction forces in the system of forces (contact force, body weight, and abductor muscle).. The results were shown in terms of displacement, compression and deformation. The model implanted with a prosthesis with a lattice design presented a slight decrease in displacement, and a decrease in compression and deformation values, which indicated that the proposed design has a better distribution and transport of the loads through its structure.
In an earlier study, Saeidi and Khodadadi presented results on forced convection inside a square cavity with one inlet and one outlet ports. Their most effective design showed maximum heat transfer and minimum pressure drop for a particular location of the ports. In the present study a cavity with one inlet and two outlet ports is considered, and different conditions and geometric arrays for the position of the ports are analyzed. The cold incoming fluid is heated by the isothermal hot walls. The outlet ports are positioned at forty-five different locations on the walls. A Reynolds number range of 10 < Re < 500 is considered, clearly within the laminar regimen. The flow and temperature fields are obtained as part of the solution. As expected, an increment of vorticity brought a heat transfer enhancement. The effect of the outlet ports and their location is discussed.
The present study evaluates the effects of a protruding heat sink located on one of the vertical walls of a cubic cavity, with a free convective laminar regimen. The best of three locations for the heat sink will be determined with the analysis of the velocity and temperature fields in the cavity. An optimal operation condition is required since the cavity will contain medical products with a specific temperature range. Three different locations for the heat sink, (in the +Y direction), are to be studied: 1/3 H, 1/2 H and 2/3 H, where H is the height of the cavity, for different values of Rayleigh Number 103
The present study evaluates the effects of a protruding heat sink located on one of the vertical walls of a cubic cavity, with a free convective laminar regimen. The best of three locations for the heat sink will be determined with the analysis of the velocity and temperature fields in the cavity. An optimal operation condition is required since the cavity will contain medical products with a specific temperature range. Three different locations for the heat sink, (in the +Y direction), are to be studied: 1/3 H, 1/2 H and 2/3 H, where H is the height of the cavity, for different values of Rayleigh Number 103