Nongnapat Eakpunyakul

Nongnapat Eakpunyakul

Auto-generated profile, based on publicly available information

Nongnapat Eakpunyakul

Master of Science Program in Oral Medicine, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2022 in Heliyon
Verified
Journal Article
Open access
PPPeraya Puapichartdumrong
Peraya Puapichartdumrong
NENongnapat Eakpunyakul
Nongnapat Eakpunyakul
STSuphakarn Tanpumiprathet
Suphakarn Tanpumiprathet
PKPimrekha Khueankaew
Pimrekha Khueankaew
PSPriawwan Saelim
Priawwan Saelim
TPThosapol Piyapattamin
Thosapol Piyapattamin
To compare the cone-cutting error frequency and the X-ray cone alignment time in the horizontal tube-shift technique between the newly designed angulation-adjustable and the extension cone paralleling (XCP) holders, by dental students. Two film holders were assigned for a random test. The mandibular left first molar position of a laboratory phantom head was used. Intraoral periapical radiography was performed horizontally at right-angle, 20° mesial-, and 20° distal projections by fifth-year dental students (n = 41). The cone-cutting error frequency and the X-ray cone alignment time were measured and analyzed statistically at a significant level of p < 0.05. Using the two holders at right angle caused no significant difference (p > 0.05) in the cone-cutting error frequency or the X-ray cone alignment time. At the horizontal tube-shift angles, some significantly greater frequencies of cone-cutting errors at both 20° mesial (43.9%) and 20° distal (73.2%) shifts were detected in the XCP group, but none in the angulation-adjustable group. For X-ray cone alignment time at both 20° mesial and 20° distal shifts, the XCP group spent a significantly longer time (p < 0.05) than the angulation-adjustable group. The usages of the angulation-adjustable holder in the horizontal tube-shift technique resulted in none of the cone-cutting error and a significant reduction of time for the X-ray cone alignment, when compared to those of the XCP instrument. The angulation-adjustable holder effectively reduced cone cutting error and treatment time, both of which were beneficial to the patients and the dental personnel.

10 April 2025 in Journal of Evidence-Based Dental Practice
Verified
Journal Article
Closed access
NENongnapat Eakpunyakul
Nongnapat Eakpunyakul
PKPeerawas Kopongpanich
Peerawas Kopongpanich
KBKanokporn Bhalang
Kanokporn Bhalang
JLJittima Amie Luckanagul
Jittima Amie Luckanagul