Ralf Vick

Ralf Vick

Auto-generated profile, based on publicly available information

Ralf Vick

Chair of Electromagnetic Compatibility, Otto-von-Guericke University, Magdeburg, Germany

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 April 2023 in IEEE Access
Verified
Journal Article
Open access
BHBenjamin Hoepfner
Benjamin Hoepfner
RVRalf Vick
Ralf Vick
This paper offers a detailed analysis as well as a tuning and discretization approach of the presented frequency-fixed dual second order generalized integrator based phase-locked loop (FFDSOGI-PLL) for three-phase power systems. The method combines different single- and three-phase PLL approaches by ensuring high phase- and frequency tracking properties. The comparison with the standard frequency-variable DSOGI-PLL and three different recently published three-phase frequency and phase-angle estimation systems shows, that this approach gives a fast and stable phase and frequency detection of the grid voltage with very low computational burden. The results are applicable to, for instance, photovoltaic or frequency converters or active power filters.

21 July 2020 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
MRMoustafa Raya
Moustafa Raya
RVRalf Vick
Ralf Vick
This article introduces novel SPICE models for coaxial cables with braided shielding over a ground plane. The models are derived from the transmission line theory for single and multiconductor cables. They can be used to calculate the voltage at the termination loads when an incident uniform plane wave couples to the cable. The models can also calculate the conductive coupling due to lumped sources. They take into account the bidirectional coupling between the inside and outside of the shield and enable the analysis of immunity and emissions. The coupling functions between the inner and outer systems are designed in the form of equivalent circuits, which allow the use of the models in the frequency domain or together with nonlinear elements in the time domain. The results of the models agree very well with those of field simulations.

11 December 2018 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
MRMoustafa Raya
Moustafa Raya
RVRalf Vick
Ralf Vick
In this paper, a network model for a shielded coaxial cable with a single braid placed above a ground plane is presented. The model is developed on a SPICE basis, taking into account the coupling from the outer system between the screen and the ground to the inner system between the core and the screen, and vice versa. The model enables determining the common-mode current on the cable shield. It considers the boundary conditions at the cable ends and can thus be integrated into circuits for conducted immunity and emission simulation. An immunity test can be simulated by applying a disturbance voltage or current to the shielding ends. The model can be used in the time domain along with non-linear elements or in the frequency domain. The cable is not divided into segments, and no inverse Fourier transform is applied. The results of the model are in good agreement with those of the measurements and the numerical simulations.

23 May 2018 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
FMFelix Middelstaedt
Felix Middelstaedt
STSergey V. Tkachenko
Sergey V. Tkachenko
RVRalf Vick
Ralf Vick
This article deals with the analytic determination of the current reflection coefficient for a wire above ground. The trajectory of the wire at the wire terminal is arbitrary and the wire is connected to the ground with an impedance. The reflection coefficient is approximated by an iterative approach for the solution of the so called mixed potential integral equations. The iteration is initialized by the classical transmission line solution. The tangential electric field on the surface of the thin wire corresponding to the classical solution is then used as a distributed source to determine a correction term for the current. By this way the scattering of the transverse electromagnetic modes at the discontinuity is included. Very good agreement between the analytic solution and a numerical one is observed. It is shown that broadband matching is not possible with a frequency independent load. The importance of the incorporation of the high frequency effects is highlighted by the evaluation of the natural frequencies for two specific wire configurations.

1 September 2013
Verified
Conference Paper
Closed access
STS. V. Tkachenko
S. V. Tkachenko
JNJ. Nitsch
J. Nitsch
RVR. Vick
R. Vick
Farhad RachidiFarhad Rachidi
Farhad Rachidi
DPD. Poljak
D. Poljak
This paper deals with the calculation of first layer SEM poles of a long loaded transmission line above conducting ground excited by high frequency electromagnetic fields. This set of poles yields the main contribution to the susceptibility of the transmission line to the pulse excitations. For the case of an open-circuit wire, SEM poles are obtained in explicit form. The comparison of the results of this SEM approach with those of a numerical simulation gives a good agreement.

10 July 2025 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
BHBenjamin Hoepfner
Benjamin Hoepfner
RVRalf Vick
Ralf Vick
Phase-locked loops (PLLs) are frequency and phase-angle detection systems, which are useful to synchronize converters to the grid. The frequency-fixed dual second-order generalized integrator-PLL (FFDSOGI-PLL) is a three-phase application that has low computational burden, harmonic rejection capability, and is always stable. However, one drawback appears when a dc offset occurs in the supplying voltage. This article provides a simple but effective method for a full dc offset cancellation, while retaining the advantages of the FFDSOGI-PLL like a 20 dB reduction of low-order harmonics and two to six times less execution time compared to other PLL types with dc-rejection capability. Furthermore, the interdependency between phase tracking, disturbance rejection, and execution time will be discussed. In this context, two parameter sets will be presented, enabling a user to choose between fast tracking and high disturbance rejection. The result is a PLL that is applicable to most grid-connected converters like photovoltaic inverters or active power filters.