Bruce E. Knudsen

Bruce E. Knudsen

Auto-generated profile, based on publicly available information

Bruce E. Knudsen

Biomedical engineering, University of Wisconsin System, 500 Lincoln Dr, Madison, Wisconsin, 53706-1525, United States

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2023 in Journal of Neural Engineering
Verified
Journal Article
Open access
PDF file
SBStephan L Blanz
Stephan L Blanz
EMEric D Musselman
Eric D Musselman
MSMegan L Settell
Megan L Settell
BKBruce E Knudsen
Bruce E Knudsen
ENEvan N Nicolai
Evan N Nicolai
Kip A. LudwigKip A. Ludwig
Kip A. Ludwig
Electrical stimulation of the cervical vagus nerve using implanted electrodes (VNS) is FDA-approved for the treatment of drug-resistant epilepsy, treatment-resistant depression, and most recently, chronic ischemic stroke rehabilitation. However, VNS is critically limited by the unwanted stimulation of nearby neck muscles—a result of non-specific stimulation activating motor nerve fibers within the vagus. Prior studies suggested that precise placement of small epineural electrodes can modify VNS therapeutic effects, such as cardiac responses. However, it remains unclear if placement can alter the balance between intended effect and limiting side effect. We used an FDA investigational device exemption approved six-contact epineural cuff to deliver VNS in pigs and quantified how epineural electrode location impacts on- and off-target VNS activation. Detailed post-mortem histology was conducted to understand how the underlying neuroanatomy impacts observed functional responses. Here we report the discovery and characterization of clear neuroanatomy-dependent differences in threshold and saturation for responses related to both effect (change in heart rate) and side effect (neck muscle contractions). The histological and electrophysiological data were used to develop and validate subject-specific computation models of VNS, creating a well-grounded quantitative framework to optimize electrode location-specific activation of nerve fibers governing intended effect versus unwanted side effect.

1 April 2023 in Journal of Neural Engineering
Verified
Journal Article
Open access
PDF file
NVNishant Verma
Nishant Verma
BKBruce Knudsen
Bruce Knudsen
AGAaron Gholston
Aaron Gholston
ASAaron C Skubal
Aaron C Skubal
SBStephan L Blanz
Stephan L Blanz
Kip A. LudwigKip A. Ludwig
Kip A. Ludwig
Objective. Peripheral neural signals recorded during neuromodulation therapies provide insights into local neural target engagement and serve as a sensitive biomarker of physiological effect. Although these applications make peripheral recordings important for furthering neuromodulation therapies, the invasive nature of conventional nerve cuffs and longitudinal intrafascicular electrodes (LIFEs) limit their clinical utility. Furthermore, cuff electrodes typically record clear asynchronous neural activity in small animal models but not in large animal models. Microneurography, a minimally invasive technique, is already used routinely in humans to record asynchronous neural activity in the periphery. However, the relative performance of microneurography microelectrodes compared to cuff and LIFE electrodes in measuring neural signals relevant to neuromodulation therapies is not well understood. Approach. To address this gap, we recorded cervical vagus nerve electrically evoked compound action potentials (ECAPs) and spontaneous activity in a human-scaled large animal model—the pig. Additionally, we recorded sensory evoked activity and both invasively and non-invasively evoked CAPs from the great auricular nerve. In aggregate, this study assesses the potential of microneurography electrodes to measure neural activity during neuromodulation therapies with statistically powered and pre-registered outcomes (https://osf.io/y9k6j). Main results. The cuff recorded the largest ECAP signal (p < 0.01) and had the lowest noise floor amongst the evaluated electrodes. Despite the lower signal to noise ratio, microneurography electrodes were able to detect the threshold for neural activation with similar sensitivity to cuff and LIFE electrodes once a dose-response curve was constructed. Furthermore, the microneurography electrodes recorded distinct sensory evoked neural activity. Significance. The results show that microneurography electrodes can measure neural signals relevant to neuromodulation therapies. Microneurography could further neuromodulation therapies by providing a real-time biomarker to guide electrode placement and stimulation parameter selection to optimize local neural fiber engagement and study mechanisms of action.

1 February 2025 in Journal of Neural Engineering
Verified
Journal Article
Open access
ADAshlesha Deshmukh
Ashlesha Deshmukh
MSMegan Settell
Megan Settell
KCKevin Cheng
Kevin Cheng
BKBruce Knudsen
Bruce Knudsen
JTJames Trevathan
James Trevathan
Kip A. LudwigKip A. Ludwig
Kip A. Ludwig
Objective. Evoked compound action potentials (ECAPs) measured during epidural spinal cord stimulation (SCS) can help elucidate fundamental mechanisms for the treatment of pain and inform closed-loop control of SCS. Previous studies have used ECAPs to characterize neural responses to various neuromodulation therapies and have demonstrated that ECAPs are highly prone to multiple sources of artifact, including post-stimulus pulse capacitive artifact, electromyography (EMG) bleed-through, and motion artifact. However, a thorough characterization has yet to be performed for how these sources of artifact may contaminate recordings within the temporal window commonly used to determine activation of A-beta fibers in a large animal model. Approach. We characterized sources of artifacts that can contaminate the recording of ECAPs in an epidural SCS swine model using the Abbott Octrode™ lead. Main results. Spinal ECAP recordings can be contaminated by capacitive artifact, short latency EMG from nearby muscles of the back, and motion artifact. The capacitive artifact can appear nearly identical in duration and waveshape to evoked A-beta responses. EMG bleed-through can have phase shifts across the electrode array, similar to the phase shift anticipated by propagation of an evoked A-beta fiber response. The short latency EMG is often evident at currents similar to those needed to activate A-beta fibers associated with the treatment of pain. Changes in CSF between the cord and dura, and motion induced during breathing created a cyclic oscillation in all evoked components of recorded ECAPs. Significance. Controls must be implemented to separate neural signal from sources of artifact in SCS ECAPs. We suggest experimental procedures and reporting requirements necessary to disambiguate underlying neural response from these confounds. These data are important to better understand the framework for epidural spinal recordings (ESRs), with components such as ECAPs, EMG, and artifacts, and have important implications for closed-loop control algorithms to account for transient motion such as postural changes and cough.

1 June 2013 in American Journal of Roentgenology
Verified
Journal Article
Closed access
JRJuan C. Ramirez-Giraldo
Juan C. Ramirez-Giraldo
STScott M. Thompson
Scott M. Thompson
GKGanapathy Krishnamurthi
Ganapathy Krishnamurthi
BKBruce E. Knudsen
Bruce E. Knudsen
DWDavid Woodrum
David Woodrum
CMCynthia H. McCollough
Cynthia H. McCollough
OBJECTIVE. The purpose of this study is to evaluate radiation dose reduction strategies in perfusion CT by using a biologic phantom. MATERIALS AND METHODS. A formalin-preserved porcine liver was submerged in a 32-cm-wide acrylic phantom filled with water. The portal vein was connected to a continuous flow pump. The phantom was scanned with a perfusion CT protocol using 80 kVp and 400 mAs, every 1 second, for 50 seconds. This was repeated using 100 and 20 mAs. It was also repeated again using 400 mAs to assess reproducibility. A sparser scan frequency was simulated retrospectively. Blood flow was determined for each dataset using the maximum slope and deconvolution methods. RESULTS. Measurements of the mean blood flow values in identical regions of interest had a percent difference of 7% for repeated perfusion CT protocols using the same settings regardless of perfusion model used. The 100 mAs scans agreed with 400 mAs scans, with percent differences of 21% and 31% for the maximum slope and deconvolution methods, respectively. At a simulated frequency of one scan every 4 seconds, blood flow values differed up to 17% and 60% from the reference scan for the maximum slope and deconvolution methods, respectively. At 20 mAs and one scan every 1 second, or 400 mAs and a simulated frequency of one scan every 8 seconds, both computation methods failed to provide accurate blood flow estimates. CONCLUSION. The biologic phantom showed reproducible measurements that can help in optimizing perfusion CT protocols by determining both the acquisition parameters that affect radiation dose and the accuracy of estimates from different perfusion models.

24 December 2020 in bioRxiv
Verified
Preprint
Open access
PDF file
MSMegan L. Settell
Megan L. Settell
MKMaïsha Kasole
Maïsha Kasole
ASAaron C. Skubal
Aaron C. Skubal
BKBruce E. Knudsen
Bruce E. Knudsen
ENEvan N. Nicolai
Evan N. Nicolai
Kip A. LudwigKip A. Ludwig
Kip A. Ludwig
Background Placement of the clinical vagus nerve stimulating cuff is a standard surgical procedure based on anatomical landmarks, with limited patient specificity in terms of fascicular organization or vagal anatomy. As such, the therapeutic effects are generally limited by unwanted side effects of neck muscle contractions, demonstrated by previous studies to result from stimulation of 1) motor fibers near the cuff in the superior laryngeal and 2) motor fibers within the cuff projecting to the recurrent laryngeal. Objective The use of patient-specific visualization of vagus nerve fascicular organization could better inform clinical cuff placement and improve clinical outcomes. Methods The viability of ultrasound, with the transducer in the surgical pocket, to visualize vagus nerve fascicular organization (i.e. vagotopy) was characterized in a pig model. Ultrasound images were matched to post-mortem histology to confirm the utility of ultrasound in identifying fascicular organization. Results High-resolution ultrasound accurately depicted the vagotopy of the pig vagus nerve intra-operatively, as confirmed via histology. The stereotypical pseudo-unipolar cell body aggregation at the nodose ganglion was identifiable, and these sensory afferent fascicular bundles were traced down the length of the vagus nerve. Additionally, the superior and recurrent laryngeal nerves were identified via ultrasound. Conclusions Intraoperative visualization of vagotopy and surrounding nerves using ultrasound is a novel approach to optimize stimulating cuff placement, avoid unwanted activation of motor nerve fibers implicated in off-target effects, and seed patient-specific models of vagal fiber activation to improve patient outcomes.

27 May 2025 in bioRxiv
Verified
Preprint
Open access
PDF file
ADAshlesha Deshmukh
Ashlesha Deshmukh
RCRex Chin-Hao Chen
Rex Chin-Hao Chen
JCJustin Chin
Justin Chin
BKBruce Knudsen
Bruce Knudsen
JTJames Trevathan
James Trevathan
Kip A. LudwigKip A. Ludwig
Kip A. Ludwig
Introduction Electrical stimulation of the vagus nerve (VNS) is an FDA approved therapy for epilepsy, depression and rehabilitation after stroke, with recent clinical trials to treat heart failure and inflammation. VNS is often assumed to activate either parasympathetic efferents projecting to visceral organs, and/or sensory afferents projecting from these organs, for its therapeutic effects. Recent studies in humans, swine and dogs have shown that sympathetic nerve fibers from the sympathetic trunk (ST) can frequently be found within the cervical vagus nerve (VN). However, the prevalence and functional consequence of sympathetic fibers on VNS have yet to be elucidated in the most common high throughput animal model to study disease, the rodent. Methods We carefully traced ST from sympathetic cervical ganglion (SCG) to find its location in the carotid sheath with reference to the VN in a cohort of Long Evans rats. We then assessed the prevalence of ST fibers with the cervical VN across the cohort using microCT and immunohistochemistry. Finally, we stimulated the VN and the ST in isolation, and where they were conjoined, to evaluate the ST contribution to changes in heart rate. VNS induced heart rate changes are a commonly used surrogate for changes in sympathetic/parasympathetic tone. Results The ST frequently runs in very close proximity to the VN in rats when traced caudally from the SCG. The ST is even conjoined with the VN for stretches within the carotid sheathe at the most common location to place an epineural cuff. Cross-connecting branches were found between the ST and the VN. VNS performed at locations where there was minimal ST crossover induced dose-dependent bradycardia (decrease in heart rate) across the cohort, with detectable bradycardia across the cohort beginning at 50 μA (n=8 right, n=3 left). Conversely, stimulation of the isolated ST induced tachycardia (increase in heart rate) across the cohort beginning at ∼200 μA (n=7 right, n=3 left). Conclusion These data suggest that studies of VNS in the rodent model may also be stimulating sympathetic fibers from the ST in addition to canonical VN pathways. Concurrent sympathetic activation has profound implications for dissecting mechanisms of VNS for a host of diseases/disorders. As such, careful post-mortem assessment of the presence of ‘hitchhiking’ sympathetic fibers within the VN is critical for understanding sources of variability in VNS outcomes.