7 January 2019 in IEEE Transactions on Industrial Informatics
Eddy current thermography (ECT) as one of the emerging nondestructive testing and evaluation techniques has been used for defects detection in critical components, e.g. fatigue cracks in turbine blades, bond wire lift-off in IGBT modules, lack of fusion in welded parts, etc. However, in fast inspection using the early thermal response, the thin eddy current penetration depth (skin depth) of ferromagnetic materials limits ECT's capability of detecting subsurface defects. In order to increase the detectable depth range, this paper proposes a DC-biased magnetization based ECT (DCMECT) technique. Based on the nonlinear magnetic permeability in ferromagnetic material, DCMECT can increase the thermal contrast between the defective and sound areas by the enhanced permeability distortion in the skin-depth layer. Specifically, the influences of DC-biased magnetization direction and intensity on the thermal responses (of the defective and sound areas) and their thermal contrast are investigated. Results show that the DC-biased magnetization direction has the strongest influence on the thermal response when it is parallel to the AC magnetization direction generated by the coil. Both the thermal responses of defective and sound areas decrease with the magnetization intensity increasing. Whereas, the thermal contrast between two areas increases with the magnetization intensity, which presents the enhanced defect detectability of DCMECT. The proposed technique can detect the subsurface defect with a buried depth up to 6 mm.
18 June 2020 in IEEE Transactions on Industrial Informatics
Locating and characterizing rolling contact fatigue (RCF) cracking in rails is gaining attention in the railway industry. Eddy current pulsed thermography (ECPT), by combining the benefits of electromagnetic excitation and thermal diffusion, can detect such cracks. To date, most studies focus on investigating specific features based on man-made specimens and verification on real cracks is lacking. To establish the best means of characterizing cracks of different inclination angles, eight spatial and temporal ECPT features are evaluated on idealized and real RCF cracks. Results show that longer time slots and pulse durations make the relations clearer. For evaluation of real RCF cracks, the area-based and the kurtosis-based features are the most suitable and robust measures for characterizing inclination angles.
21 August 2018 in IEEE Transactions on Industrial Informatics
Eddy current pulsed thermography (ECPT) as one of the emerging NDT&E nondestructive testing and evaluation techniques has been used for the evaluation of the integrity of rail tracks, especially for rolling contact fatigue (RCF) detection and crack sizing. This paper proposes a probability of detection (POD) analysis framework for the ECPT system. Specifically, three different features, i.e. max thermal response, first-order different imaging and its ratio mapping, were used to quantify the length of the angular slot by linear fitting. Based on the fitting relation between these features and the slot length, POD curves for linear-coil based ECPT system of angular defect detection were calculated and compared. Results show that max thermal response feature has the highest repeatability and detectability for shorter slot detection. First-order different imaging and ratio mapping features are more convincing for longer slot detection.
27 May 2022 in NDT & E International
23 January 2019 in IEEE Transactions on Instrumentation and Measurement
As one promising nondestructive testing technique, eddy current pulsed thermography has been used for detecting the defects in rail tracks, e.g., rolling contact fatigue (RCF) cracking. This paper introduces and compares three features for the pocket length quantification of artificial angular defects and natural RCF cracks. Specifically, the maximum thermal response and two principal component analysis (PCA)-based features (PCA-based thermal pattern and PCA-based first-order differential pattern) are utilized to quantify the pocket length by linear fitting. For evaluating and comparing the fitted relations between three introduced features and the pocket length, two criteria (R² and 2-norm of the residual) are used. Through comparisons, three features' strengths and limitations are summarized. Furthermore, a real RCF specimen is used to verify the comparison results.
11 June 2021 in IEEE Sensors Journal
Wire ropes (WRs) are widely used in various areas, such as tourist cables, mining, and elevators. Thus, it is very important to detect broken wires (BWs) to prevent safety issues. To guarantee the structural health of WRs, this paper proposes the use of induction thermography (IT) to detect the BWs. An image segmentation algorithm based on scale morphology is proposed to eliminate the background influence of non-uniform heating and visualize the BWs. Further, the area of the BW region, after the image binarization, subtraction, and filtering, is extracted as a feature to quantify the number of BWs. Results show that the proposed methods can effectively visualize and quantify the broken region within 1 BWs.