William L. Trimble

William L. Trimble

Auto-generated profile, based on publicly available information

William L. Trimble

Physics Division, Argonne National Laboratory, Argonne, Illinois 60439, USA

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 December 2015 in Nucleic Acids Research
Verified
Journal Article
Open access
PDF file
AWAndreas Wilke
Andreas Wilke
JBJared Bischof
Jared Bischof
WGWolfgang Gerlach
Wolfgang Gerlach
EGElizabeth Glass
Elizabeth Glass
THTravis Harrison
Travis Harrison
FMFolker Meyer
Folker Meyer
MG-RAST (http://metagenomics.anl.gov) is an open-submission data portal for processing, analyzing, sharing and disseminating metagenomic datasets. The system currently hosts over 200 000 datasets and is continuously updated. The volume of submissions has increased 4-fold over the past 24 months, now averaging 4 terabasepairs per month. In addition to several new features, we report changes to the analysis workflow and the technologies used to scale the pipeline up to the required throughput levels. To show possible uses for the data from MG-RAST, we present several examples integrating data and analyses from MG-RAST into popular third-party analysis tools or sequence alignment tools.

31 August 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
AOAndrea D. Olivas
Andrea D. Olivas
BSBenjamin D. Shogan
Benjamin D. Shogan
VVVesta Valuckaite
Vesta Valuckaite
AZAlexander Zaborin
Alexander Zaborin
NBNatalya Belogortseva
Natalya Belogortseva
OZOlga Zaborina
Olga Zaborina
The most feared complication following intestinal resection is anastomotic leakage. In high risk areas (esophagus/rectum) where neoadjuvant chemoradiation is used, the incidence of anastomotic leaks remains unacceptably high (∼10%) even when performed by specialist surgeons in high volume centers. The aims of this study were to test the hypothesis that anastomotic leakage develops when pathogens colonizing anastomotic sites become in vivo transformed to express a tissue destroying phenotype. We developed a novel model of anastomotic leak in which rats were exposed to pre-operative radiation as in cancer surgery, underwent distal colon resection and then were intestinally inoculated with Pseudomonas aeruginosa, a common colonizer of the radiated intestine. Results demonstrated that intestinal tissues exposed to preoperative radiation developed a significant incidence of anastomotic leak (>60%; p<0.01) when colonized by P. aeruginosa compared to radiated tissues alone (0%). Phenotype analysis comparing the original inoculating strain (MPAO1- termed P1) and the strain retrieved from leaking anastomotic tissues (termed P2) demonstrated that P2 was altered in pyocyanin production and displayed enhanced collagenase activity, high swarming motility, and a destructive phenotype against cultured intestinal epithelial cells (i.e. apoptosis, barrier function, cytolysis). Comparative genotype analysis between P1 and P2 revealed a single nucleotide polymorphism (SNP) mutation in the mexT gene that led to a stop codon resulting in a non-functional truncated protein. Replacement of the mutated mexT gene in P2 with mexT from the original parental strain P1 led to reversion of P2 to the P1 phenotype. No spontaneous transformation was detected during 20 passages in TSB media. Use of a novel virulence suppressing compound PEG/Pi prevented P. aeruginosa transformation to the tissue destructive phenotype and prevented anastomotic leak in rats. This work demonstrates that in vivo transformation of microbial pathogens to a tissue destroying phenotype may have important implications in the pathogenesis of anastomotic leak.

26 September 2017 in Briefings in Bioinformatics
Verified
Journal Article
Open access
PDF file
FMFolker Meyer
Folker Meyer
SBSaurabh Bagchi
Saurabh Bagchi
SCSomali Chaterji
Somali Chaterji
WGWolfgang Gerlach
Wolfgang Gerlach
AGAnanth Grama
Ananth Grama
AWAndreas Wilke
Andreas Wilke
As technologies change, MG-RAST is adapting. Newly available software is being included to improve accuracy and performance. As a computational service constantly running large volume scientific workflows, MG-RAST is the right location to perform benchmarking and implement algorithmic or platform improvements, in many cases involving trade-offs between specificity, sensitivity and run-time cost. The work in [Glass EM, Dribinsky Y, Yilmaz P, et al. ISME J 2014;8:1–3] is an example; we use existing well-studied data sets as gold standards representing different environments and different technologies to evaluate any changes to the pipeline. Currently, we use well-understood data sets in MG-RAST as platform for benchmarking. The use of artificial data sets for pipeline performance optimization has not added value, as these data sets are not presenting the same challenges as real-world data sets. In addition, the MG-RAST team welcomes suggestions for improvements of the workflow. We are currently working on versions 4.02 and 4.1, both of which contain significant input from the community and our partners that will enable double barcoding, stronger inferences supported by longer-read technologies, and will increase throughput while maintaining sensitivity by using Diamond and SortMeRNA. On the technical platform side, the MG-RAST team intends to support the Common Workflow Language as a standard to specify bioinformatics workflows, both to facilitate development and efficient high-performance implementation of the community’s data analysis tasks.

21 April 2014 in Environmental Microbiology
Verified
Journal Article
Closed access
PDF file
KHKim M. Handley
Kim M. Handley
DBDaniela Bartels
Daniela Bartels
Edward O'LoughlinEdward O'Loughlin
Edward O'Loughlin
KWKenneth H. Williams
Kenneth H. Williams
WTWilliam L. Trimble
William L. Trimble
FMFolker Meyer
Folker Meyer

7 June 2012 in PLOS Computational Biology
Verified
Journal Article
Open access
PDF file
KKKevin P. Keegan
Kevin P. Keegan
WTWilliam L. Trimble
William L. Trimble
JWJared Wilkening
Jared Wilkening
AWAndreas Wilke
Andreas Wilke
THTravis Harrison
Travis Harrison
FMFolker Meyer
Folker Meyer
We provide a novel method, DRISEE (duplicate read inferred sequencing error estimation), to assess sequencing quality (alternatively referred to as “noise” or “error”) within and/or between sequencing samples. DRISEE provides positional error estimates that can be used to inform read trimming within a sample. It also provides global (whole sample) error estimates that can be used to identify samples with high or varying levels of sequencing error that may confound downstream analyses, particularly in the case of studies that utilize data from multiple sequencing samples. For shotgun metagenomic data, we believe that DRISEE provides estimates of sequencing error that are more accurate and less constrained by technical limitations than existing methods that rely on reference genomes or the use of scores (e.g. Phred). Here, DRISEE is applied to (non amplicon) data sets from both the 454 and Illumina platforms. The DRISEE error estimate is obtained by analyzing sets of artifactual duplicate reads (ADRs), a known by-product of both sequencing platforms. We present DRISEE as an open-source, platform-independent method to assess sequencing error in shotgun metagenomic data, and utilize it to discover previously uncharacterized error in de novo sequence data from the 454 and Illumina sequencing platforms. Sequence quality (referred to alternatively as the level of sequencing error or noise) is a primary concern to all sequence-dependent investigations. This is particularly true in the field of metagenomics where automated tools (e.g. annotation pipelines like MG-RAST) rely on high fidelity sequence data to derive meaningful biological inferences, and is exacerbated by the capacity of next generation sequencing platforms that continue to expand at a rate greater than Moore's law. We demonstrate that the most commonly utilized means to assess sequencing error exhibit severe limitations with respect to analysis of metagenomic data. Furthermore, we introduce a method (DRISEE) that accounts for these limitations through the application of a novel approach to assess sequencing error. DRISEE-based analyses reveal previously unobserved levels of sequencing error. DRISEE provides a platform independent measure of sequencing error that objectively assesses the quality of entire sequence samples. This assessment can be used to exclude low quality samples from computationally expensive analyses (e.g. annotation). It can also be used to evaluate the relative fidelity of analyses after they have been performed (e.g. annotation of error prone samples is less reliable than that of samples with low levels of sequencing error).

13 May 2004 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
JCJ. A. Clark
J. A. Clark
GSG. Savard
G. Savard
KSK. S. Sharma
K. S. Sharma
JVJ. Vaz
J. Vaz
JWJ. C. Wang
J. C. Wang
WTW. Trimble
W. Trimble
Mass measurements of Ge68, As68, and Se68 have been obtained with the Canadian Penning Trap mass spectrometer. The results determine the mass excess of Se68 as −54 232(19)  keV, the first measurement with a precision and reliability sufficient to address the light-curve and energy output of x-ray bursts as well as the abundances of the elements synthesized. Under typical conditions used for modeling x-ray bursts, Se68 is found to cause a significant delay in the rp process nucleosynthesis.