An underwater wireless optical communication link can provide high-speed data transfer for robotics applications in deep waters. However, optical links are limited in terms of coverage range because of the high attenuation of light in water caused by absorption and scattering effects. In this work, a new optical transceiver architecture is proposed to solve this coverage problem via a novel Orthogonal Frequency Division Multiplexing (OFDM)-based Polarized Pulse Position Modulation (in short, P-OFDM-PPM) with time-frequency spreading. The optical polarization diversity and multiplexing are utilized at the optical transmitter to improve the system’s robustness and the transmission data rate. This new scheme is able to boost the range coverage by several folds as verified via simulations using realistic models of optical channel propagation. The proposed architecture can be integrated into existing underwater robots to enable next-generation range-extended and high-speed optical links for oceanic explorations.
29 May 2018 in IEEE Transactions on Biomedical Circuits and Systems
Wireless all-analog biosensor design for the concurrent microfluidic and physiological signal monitoring is presented in this paper. The key component is an all-analog circuit capable of compressing two analog sources into one analog signal by the analog joint source-channel coding (AJSCC). Two circuit designs are discussed, including the stacked-voltage-controlled voltage source (VCVS) design with the fixed number of levels, and an improved design, which supports a flexible number of AJSCC levels. Experimental results are presented on the wireless biosensor prototype, composed of printed circuit board realizations of the stacked-VCVS design. Furthermore, circuit simulation and wireless link simulation results are presented on the improved design. Results indicate that the proposed wireless biosensor is well suited for sensing two biological signals simultaneously with high accuracy, and can be applied to a wide variety of low-power and low-cost wireless continuous health monitoring applications.
31 January 2022 in IEEE Transactions on Wireless Communications
The signal recovery performance of the rectangular-type Analog Joint Source-Channel Coding (AJSCC) is analyzed in this work for high and medium/low Signal-to-Noise Ratio (SNR) scenarios in a wireless sensing system with the Doppler channel. The analytical formulations of the Mean Square Error (MSE) performance are derived based on the geometry of the rectangular-type AJSCC on analog sensing and system with Doppler effects. The comprehensive listing of all cases in the three-dimensional geometric signal mapping curve is provided to obtain the theoretical formulations for the medium/low SNR scenario. Evaluation results indicate that there are optimal parameters in the rectangular-type AJSCC to minimize the signal recovery MSE for analog sensing and system with Doppler effects in both high and medium/low SNR scenarios. The analysis of the work provides insights on the optimization of the rectangular-type AJSCC in practical wireless sensing systems.
A low-power wearable wireless sensor measuring both molecular biomarkers and physiological signals is proposed, where the former are measured by a microfluidic biosensing system while the latter are measured electrically. The low-power consumption of the sensor is achieved by an all-analog circuit implementing Analog Joint Source-Channel Coding (AJSCC) compression. The sensor is applicable to a wide range of biomedical applications that require real-time concurrent molecular biomarker and physiological signal monitoring.