Omar J. Portillo Castillo

Omar J. Portillo Castillo

Auto-generated profile, based on publicly available information

Omar J. Portillo Castillo

Universidad Autonóma de Nuevo León

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2018 in Reviews in Analytical Chemistry
Verified
Journal Article
Open access
PDF file
OPOmar J. Portillo-Castillo
Omar J. Portillo-Castillo
RCRocío Castro-Ríos
Rocío Castro-Ríos
ACAbelardo Chávez-Montes
Abelardo Chávez-Montes
AGAzucena González-Horta
Azucena González-Horta
NCNorma Cavazos-Rocha
Norma Cavazos-Rocha
MTMarsela Garza Tapia
Marsela Garza Tapia
Solid-phase microextraction (SPME) is a sample preparation technique with many applications that is being continuously developed. In this technique, the type of fiber coating plays a crucial role for extraction efficiency. Currently available commercial coatings have certain drawbacks that have been overcome by the development of new coatings based on novel materials; these have improved the efficiency of extraction, selectivity and stability of commercial coatings. Pharmaceutical and personal care products (PPCPs) are one of the most important groups of emerging contaminants; however, some studies suggest that these compounds can cause adverse health effects. No official monitoring protocols for these compounds are currently available, so the establishment of analytical methods that allow their determination in environmental samples is required. The complexity of environmental samples together with the low concentration levels of these compounds makes necessary the use of sample preparation techniques capable of removing interferences, as well as preconcentrated analytes, and SPME is a very promising alternative to achieve this. This review describes the recent developments in SPME with classical and novel coatings and its applications for PPCP determination in environmental samples.

30 June 2009 in Journal of Antimicrobial Chemotherapy
Verified
Journal Article
Closed access
GGGloria M. González
Gloria M. González
OPOmar J. Portillo
Omar J. Portillo
GUGrecia I. Uscanga
Grecia I. Uscanga
SASamantha E. Andrade
Samantha E. Andrade
MRMiguel Robledo
Miguel Robledo
MEMariana Elizondo
Mariana Elizondo
The purpose of this study was to assess the therapeutic efficacy of oral versus intravaginal voriconazole and compare it with fluconazole for the treatment of experimental vaginitis caused by a fluconazole-resistant Candida albicans isolate. Mice were treated with voriconazole at 5, 10 and 20 mg/kg once a day and 20 mg/kg twice a day or with fluconazole at 20 mg/kg once or twice a day orally. Intravaginal treatments were evaluated with voriconazole and fluconazole at 0.5, 1 and 5 mg/kg once a day. All treatment regimens were given on days 1–5 post-challenge. One day 6, the vaginas were swabbed to assess treatment effects. Mice treated orally with voriconazole at ≥10 mg/kg and fluconazole at ≥20 mg/kg showed significantly reduced fungal counts over controls (P = 0.0002–0.007). Significant differences were found between the groups that received voriconazole at 20 mg/kg once or twice daily and those that received fluconazole at 20 mg/kg once or twice daily, orally (P = 0.010 and 0.001, respectively). Mice treated with voriconazole or fluconazole administered intravaginally at ≥0.5 mg/kg exhibited a reduced fungal burden when compared with the control group (P = 0.0002–0.007). There was no statistically significant difference in fungal burden between topical treatment with doses of 0.5, 1 and 5 mg/kg once daily of voriconazole or fluconazole. Sterilization of vaginas was not observed with voriconazole and fluconazole without taking into consideration the therapeutic modality. Voriconazole could emerge as a new alternative for treatment of vaginal candidosis.

1 January 2023 in Reviews in Analytical Chemistry
Verified
Journal Article
Open access
PDF file
GGGraciela Granados-Guzmán
Graciela Granados-Guzmán
MDMónica Díaz-Hernández
Mónica Díaz-Hernández
RARocío Alvarez-Román
Rocío Alvarez-Román
NCNorma Cavazos-Rocha
Norma Cavazos-Rocha
OPOmar J. Portillo-Castillo
Omar J. Portillo-Castillo
Currently, sample preparation is the most laborious part of the analytical process, requiring the most time and being susceptible to the most errors. In this context, numerous investigations have focused on the miniaturization of these techniques to reduce work time, costs, and errors. In this regard, microextraction by packed sorbent (MEPS) is a simple, fast, and robust sample preparation technique suitable for easy automation in several analytical systems and is applied to a wide variety of samples. Antibiotics are among the most commonly used drugs; however, their extensive and inappropriate use has garnered significant attention in the environment, human health, and food safety. This brief review is intended to provide an overview of recently reported antibiotic extraction methods based on MEPS, with a special interest in those applied to the analysis of biological, environmental, and food samples. In addition, the sample pretreatment step before extraction by the MEPS device was highlighted, as was the description of the sample-related steps within the MEPS procedure, such as extraction, washing, and elution.

25 April 2023 in Acta Chromatographica
Verified
Journal Article
Open access
PDF file
LPLuis Alejandro Pérez-López
Luis Alejandro Pérez-López
NCNorma Cavazos-Rocha
Norma Cavazos-Rocha
CDCecilia Delgado-Montemayor
Cecilia Delgado-Montemayor
NWNoemí Waksman-Minsky
Noemí Waksman-Minsky
MHMarcelo Hernández-Salazar
Marcelo Hernández-Salazar
OPOmar J. Portillo-Castillo
Omar J. Portillo-Castillo
The analysis of phenolic acids (PAs) is of great importance, because they are frequently present in natural products and their derivatives, and these compounds also have multiple beneficial effects to human health. This work is focusing on the separation of seven PAs (caffeic acid, coumaric acid, gallic acid, ferulic acid, protocatechuic acid, sinapic acid, and syringic acid), in a reversed-phase liquid chromatographic (RP-HPLC) isocratic method using a hydrophilic deep eutectic solvent (DES) as a mobile phase additive. The analysis was carried out with a diode array detector. The used DES was composed by choline chloride and glycerol, and it was characterized by infrared spectroscopy. The combination of choline chloride:glycerol (1:4) added at 0.25% to mobile phase composed of 0.15% formic acid aqueous solution and methanol (80:20), showed the best separation for target analytes. The new proposed method was validated, and results indicated that the proposed method is linear, selective for almost all analytes, provided high sensitivity with limit of detection ranges from 0.009 to 0.023 mg mL−1, and has satisfactory precision and accuracy, with values of relative standard deviation of 0.24–2.65% and recoveries of 97.97–109%, respectively. Additionally, this method was successfully applied to simultaneous determination of phenolic acids in three kinds of samples of powder to prepare lemon flavour drink enriched with black tea extract.

11 April 2022 in Journal of the Mexican Chemical Society
Verified
Journal Article
Open access
PDF file
OPOmar J. Portillo-Castillo
Omar J. Portillo-Castillo
RRRocío Castro Ríos
Rocío Castro Ríos
AMAbelardo Chávez Montes
Abelardo Chávez Montes
AGAzucena González-Horta
Azucena González-Horta
NCNorma Cavazos-Rocha
Norma Cavazos-Rocha
MTMarsela Garza Tapia
Marsela Garza Tapia
A novel coating for solid-phase microextraction (SPME) fibers was manufactured by using a mixture of 1-decyl-3methylimidazolium tetrafluoroborate ionic liquid and a commercial adhesive deposited on an etched stainless-steel support. The new coating was characterized by applying optical and electron microscopy, infrared spectroscopy and its extraction capacity was also evaluated. The extraction capacity was tested using as model analytes some pharmaceutical and personal care products (PPCPs) with different hydrophilicities. The potential use of the new fiber was evaluated through direct-immersion mode extractions and showed extraction capacity toward methylparaben, propylparaben, naproxen, diclofenac and benzophenone-3. Experimental design tools were used to study and optimize the variables that affect the extraction and desorption processes of the SPME by direct immersion. The analytical performance of proposed method was investigated under SPME procedure´s optimal conditions, coupled to a high-performance liquid chromatography-diode array detector (HPLC-DAD) method, which was developed and validated for analysis of the target PPCPs. The method of SPME by direct immersion was linear, precise and accurate. Detection and quantification limits of 0.023 to 0.093 μg mL-1 and 0.118 to 0.279 μg mL-1 were obtained, respectively. By the use of the developed method, tap water samples were analyzed and recoveries from 3.39 to 183.29 % were found. The new fiber presented an adequate stability and good extraction reproducibility (<15 % RSD). As a final point, this device is of easy and quick preparation, inexpensive, and suitable for extraction of some PPCPs. Resumen. Se fabricó un nuevo recubrimiento para fibras de microextracción en fase sólida (SPME) utilizando una mezcla del líquido iónico tetrafluoroborato de 1-decil-3metilimidazolio y un adhesivo comercial depositada sobre un soporte de acero inoxidable grabado. El nuevo recubrimiento se caracterizó mediante la aplicación de microscopía óptica y electrónica, espectroscopía de infrarrojo y también se evaluó su capacidad de extracción. La capacidad de extracción se probó utilizando como analitos modelo algunos productos farmacéuticos y de cuidado personal (PPCPs) con diferentes hidrofilicidades. El uso potencial de la nueva fibra se evaluó mediante extracciones en modo de inmersión directa y mostró capacidad de extracción hacia metilparabeno, propilparabeno, naproxeno, diclofenaco y benzofenona-3. Se utilizaron herramientas del diseño experimental para estudiar y optimizar las variables que afectan los procesos de extracción y desorción de la SPME por inmersión directa. El rendimiento analítico del método propuesto se investigó en las condiciones óptimas del procedimiento de SPME, acoplado a un método de cromatografía líquida de alto rendimiento con detector de arreglo de diodos (HPLC-DAD), que fue desarrollado y validado para el análisis de los PPCPs objetivo. El método de SPME por inmersión directa fue lineal, preciso y exacto. Se obtuvieron límites de detección y cuantificación de 0.023 a 0.093 μg mL-1 y 0.118 a 0.279 μg mL-1, respectivamente. Mediante el uso del método desarrollado, se analizaron muestras de agua del grifo y se encontraron recuperaciones de 3.39 a 183.29 %. La nueva fibra presentó una adecuada estabilidad y buena reproducibilidad de extracción (<15 % RSD). Como punto final, este dispositivo es de fácil y rápida preparación, económico y adecuado para la extracción de algunos PPCPs.

21 August 2025 in Acta Chromatographica
Verified
Journal Article
Open access
PDF file
BGBarbara Johana González-Moreno
Barbara Johana González-Moreno
SRSergio Arturo Galindo Rodriguez
Sergio Arturo Galindo Rodriguez
LPLuis Alejandro Pérez-López
Luis Alejandro Pérez-López
OPOmar J. Portillo-Castillo
Omar J. Portillo-Castillo
RARocío Alvarez-Román
Rocío Alvarez-Román
The use of edible coatings (ECs) containing essential oils (EOs), such as that derived from the Thymus vulgaris plant (EO-Tv), offers a natural option for preserving and increasing the shelf life of fruit and vegetable products. However, considering their physicochemical properties, the incorporation of EOs into nanocapsules (NCs) represents an alternative to reduce their volatility and oxidation. In this way, quantitative determination of the EOs incorporated into NCs is necessary for simultaneous monitoring of their main components during the nanoencapsulation process, as well as for the future precise and accurate dosage of EO components in fruit and vegetable products. In this study, ECs were formed from NCs loaded with EO-Tv and sodium alginate (AL). The EO-Tv was characterized through GC-MS and GC-FID analysis, and it was found that the major component of EO-Tv was thymol, with an abundance of 30.91%. Subsequently, an analytical method based on HS-SPME-GC-FID was developed and validated for quantification of the EO-Tv encapsulated in NCs and incorporated into the EC. The method was found to be precise and accurate for quantification of the main components of EO-Tv in the formed EC. Once the analytical method was validated, it was established that the encapsulation efficiency was greater than 50% in the case of NC-EO-Tv purified via evaporation at reduced pressure. On the other hand, 35.78 μg cm−2 of thymol was quantified in the EC formed from the NCs and AL. The present work presents an analytical tool for simultaneous quantification of the main components of EO-Tv in NCs, as well as in the ECs formed with NCs, promoting its potential application in fruit and vegetable products.