Albert R. Cross

Albert R. Cross

Auto-generated profile, based on publicly available information

Albert R. Cross

Adjunct Professor of Physics, University of Lethbridge, Lethbridge, AB, Canada

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 1998 in Journal of Magnetic Resonance
Verified
Journal Article
Closed access
SBSteven D. Beyea
Steven D. Beyea
BBBruce J. Balcom
Bruce J. Balcom
PPPablo J. Prado
Pablo J. Prado
ACAlbert R. Cross
Albert R. Cross
CKChristopher B. Kennedy
Christopher B. Kennedy
TBTheodore W. Bremner
Theodore W. Bremner

1 July 2009 in Experimental Neurology
Verified
Journal Article
Closed access
SMSeong-Keun Moon
Seong-Keun Moon
MAMariam Alaverdashvili
Mariam Alaverdashvili
ACAlbert R. Cross
Albert R. Cross
IWIan Q. Whishaw
Ian Q. Whishaw

3 January 2005 in Medical Physics
Verified
Journal Article
Closed access
JPJuan Parra‐Robles
Juan Parra‐Robles
ACAlbert R. Cross
Albert R. Cross
GSGiles E. Santyr
Giles E. Santyr

9 June 2006 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
NANishard Abdeen
Nishard Abdeen
ACAlbert Cross
Albert Cross
GCGregory Cron
Gregory Cron
SWSteven White
Steven White
TRThomas Rand
Thomas Rand
GSGiles Santyr
Giles Santyr
We used the dual capability of hyperpolarized 129Xe for spectroscopy and imaging to develop new measures of xenon diffusing capacity in the rat lung that (analogously to the diffusing capacity of carbon monoxide or DLCO) are calculated as a product of total lung volume and gas transfer rate constants divided by the pressure gradient. Under conditions of known constant pressure breath‐hold, the volume is measured by hyperpolarized 129Xe MRI, and the transfer rate is measured by dynamic spectroscopy. The new quantities (xenon diffusing capacity in lung parenchyma (DLXeLP)), xenon diffusing capacity in RBCs (DLXeRBC), and total lung xenon diffusing capacity (DLXe)) were measured in six normal rats and six rats with lung inflammation induced by instillation of fungal spores of Stachybotrys chartarum. DLXeLP, DLXeRBC, and DLXe were 56 ± 10 ml/min/mmHg, 64 ± 35 ml/min/mmHg, and 29 ± 9 ml/min/mmHg, respectively, for normal rats, and 27 ± 9 ml/min/mmHg, 42 ± 27 ml/min/mmHg, and 16 ± 7 ml/min/mmHg, respectively, for diseased rats. Lung volumes and gas transfer times for LP (TtrLP) were 16 ± 2 ml and 22 ± 3 ms, respectively, for normal rats and 12 ± 2 ml and 35 ± 8 ms, respectively, for diseased rats. Xenon diffusing capacities may be useful for measuring changes in gas exchange associated with inflammation and other lung diseases. Magn Reson Med, 2006.

30 November 1998 in Solid State Nuclear Magnetic Resonance
Verified
Journal Article
Closed access
SBS.D. Beyea
S.D. Beyea
BBB.J. Balcom
B.J. Balcom
TBT.W. Bremner
T.W. Bremner
PPP.J. Prado
P.J. Prado
ACA.R. Cross
A.R. Cross
PGP.E. Grattan-Bellew
P.E. Grattan-Bellew

1 October 1994 in Journal of Neurosurgery
Verified
Journal Article
Closed access
MSMarcia C. da Silva
Marcia C. da Silva
JDJames M. Drake
James M. Drake
CLClaude Lemaire
Claude Lemaire
ACAlbert Cross
Albert Cross
UTUrsula I. Tuor
Ursula I. Tuor
✓ The authors studied the effects of hydrocephalus on the high-energy phosphate metabolism of the brain and the impact of ventriculoperitoneal (VP) shunting on these changes in an experimental model of hydrocephalus. High-energy phosphate metabolism was analyzed using in vivo magnetic resonance (MR) imaging and 31P MR spectroscopy. Hydrocephalus was produced in 34 1-week-old kittens by cisternal injection of 0.05 ml of a 25% kaolin solution. Sixteen litter mates were used as controls. A VP shunt with a distal slit valve was implanted in 17 of the 34 hydrocephalic animals 10 days after induction of hydrocephalus. Both MR imaging and 31P MR spectroscopy were obtained 1 and 3 weeks after either kaolin or distilled water injection. Untreated hydrocephalic animals had marked dilatation of the lateral ventricles and periventricular edema. Magnetic resonance spectroscopy showed a significant decrease in the energy index ratio of phosphocreatine (PCR): inorganic phosphate (PI) and an increase in the PI:adenosine triphosphate (ATP) ratio. There was a direct correlation between the decrease in the energy index and ventricular size. Compared with preoperative scans, shunted animals showed no periventricular edema, and the ventricles decreased in size. Also, PCR:PI and PI:ATP ratios were within the levels of controls. This study suggests that neonatal hydrocephalus results in a mild hypoxic/ischemic insult that is treatable by VP shunting.