The aim of this study was to assess the inter-reliability of the Braden scale and its subscales for different patients assisted in the intensive care unit. We hypothesized that the Braden scale has low reliability in different populations. This reliability study involved the Braden scale in intensive care unit of a hospital. A total of 200 patients were admitted to the intensive care unit in four different groups: neurological patients, sepsis, elderly, and adults affected by trauma. The Braden scale is a tool composed of six subscales for patient assessment: sensory perception, humidity, activity, mobility, nutrition, and friction. The total score was also calculated. The Braden scale was applied by two different nurses with an interval of 20–30 min between applications. For all populations, kappa values considered unsuitable were observed for most categories of the Braden scale, ranging from 0.06–0.25. Only for the total Braden scale score was moderate reliability identified in all groups evaluated, with intraclass correlation coefficient values ranging from 0.48–0.75. Braden scale is not a reliable tool to be used in the intensive care unit, and we do not recommend the use of this scale to assess the risk of developing pressure injury.
BACKGROUND: The Finnish Diabetes Risk Score (FINDRISC) is a questionnaire that was developed by Finnish researchers to track the risk of diabetes. OBJECTIVE: To translate, cross-culturally adapt and validate the FINDRISC for use in Brazilian Portuguese. DESIGN AND SETTING: Questionnaire validity study conducted at a private university. METHODS: The Brazilian version of the FINDRISC was developed through the processes of translation, back-translation, committee review and pre-testing. Test-retest reliability was measured using the intraclass correlation coefficient (ICC), kappa coefficient, standard error of measurement (SEM) and minimum detectable change (MDC). Internal consistency was measured using Cronbach's alpha. For construct validity, the total score of the FINDRISC was correlated with the Diabetes Knowledge Scale (DKN-A) and Diabetes Mellitus Risk Questionnaire (QRDM). Ceiling and floor effects were also evaluated in the present study. RESULTS: For construct validity and floor and ceiling effect measurements, a total sample of 107 participants was used. For reliability, a subsample of 51 participants out of the total sample was used. We identified adequate values for reliability (kappa = 0.79 and ICC = 0.98) and internal consistency (Cronbach's alpha = 0.84). Regarding the error inherent in the FINDRISC, we found SEM = 8.02% and MDC = 22.44%. There were significant correlations between the FINDRISC and the QRDM (r = 0.686) and DKN-A (r =-0.216). No ceiling or floor effects were found. CONCLUSION: The Brazilian version of the FINDRISC has adequate psychometric properties that are in accordance with the best international recommendations.
1 December 2021 in Revista da Associação Médica Brasileira
OBJECTIVE: The aim of this study was to translate, cross-culturally adapt, and validate the Canadian Diabetes Risk Questionnaire for use in Brazilian Portuguese. METHODS: This is a Questionnaire validity study conducted at a private university. The Brazilian version of the Canadian Diabetes Risk Questionnaire was developed by means of the processes of translation, back-translation, committee review, and pretesting. Test-retest reliability was measured using the intraclass correlation coefficient and kappa coefficient. Internal consistency was measured using Cronbach's alpha. For construct validity, the total score of the Canadian Diabetes Risk Questionnaire was correlated with the Diabetes Knowledge Scale and the Diabetes Mellitus Risk Questionnaire. Ceiling and floor effects were also evaluated in the present study. RESULTS: For construct validity and floor and ceiling effect measurements, a total sample of 100 participants was used. For reliability, a subsample of 34 participants out of the total sample was used. We identified adequate values for reliability (kappa between 0.46-1.00 and ICC 0.96) and internal consistency (Cronbach's alpha 0.80). There were significant correlations between the Canadian Diabetes Risk Questionnaire and the Diabetes Mellitus Risk Questionnaire (r(s)=0.370, p<0.001), but not the Diabetes Knowledge Scale (r(s)= -0.162). No ceiling or floor effects were found. CONCLUSION: We concluded that in accordance with the best international recommendations, the Brazilian version of the Canadian Diabetes Risk Questionnaire has adequate psychometric properties.
1 June 2021 in Revista da Associação Médica Brasileira
OBJECTIVE: The aim of this study was to verify the association among obstructive sleep apnea, functional capacity, and metabolic control. METHODS: This was a cross-sectional study involving individuals of both sexes with clinical diagnosis of diabetes mellitus type 2 who were above 18 years of age. The assessment consisted of a volunteer identification form, a 2-minute step test, and the Stop-Bang questionnaire. In order to assess metabolic control, HbA1c and fasting glucose data were collected from medical records. RESULTS: A total of 100 individuals with diabetes mellitus type 2, of whom 61% were women, were included in this study. According to the Stop-Bang instrument, 26, 57, and 17% of patients had low, intermediate, and high risk of developing OSA, respectively. There was no association between the 2-minute step test and metabolic variables and diabetes mellitus type 2 chronicity with Stop-Bang. CONCLUSIONS: We concluded that there is no association among obstructive sleep apnea measured by means of Stop-Bang instrument, functional capacity measured by means of 2-minute step test, and metabolic variables in individuals with diabetes mellitus type 2.