Andreas Lesch

Andreas Lesch

Auto-generated profile, based on publicly available information

Andreas Lesch

Institute of Medical Engineering Graz University of Technology Graz Austria

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2019 in International journal of legal medicine
Verified
Journal Article
Open access
PDF file
Bernhard NeumayerBernhard Neumayer
Bernhard Neumayer
ALAndreas Lesch
Andreas Lesch
FTFranz Thaler
Franz Thaler
TWThomas Widek
Thomas Widek
STSebastian Tschauner
Sebastian Tschauner
MUMartin Urschler
Martin Urschler
Objectives: This feasibility study aimed to investigate the reliability of multi-factorial age estimation based on MR data of the hand, wisdom teeth and the clavicles with reduced acquisition time. Methods: The raw MR data of 34 volunteers—acquired on a 3T system and using acquisition times (TA) of 3:46 min (hand), 5:29 min (clavicles) and 10:46 min (teeth)—were retrospectively undersampled applying the commercially available CAIPIRINHA technique. Automatic and radiological age estimation methods were applied to the original image data as well as undersampled data to investigate the reliability of age estimates with decreasing acquisition time. Reliability was investigated determining standard deviation (SSD) and mean (MSD) of signed differences, intra-class correlation (ICC) and by performing Bland-Altman analysis. Results: Automatic age estimation generally showed very high reliability (SSD < 0.90 years) even for very short acquisition times (SSD ≈ 0.20 years for a total TA of 4 min). Radiological age estimation provided highly reliable results for images of the hand (ICC ≥ 0.96) and the teeth (ICC ≥ 0.79) for short acquisition times (TA = 16 s for the hand, TA = 2:21 min for the teeth), imaging data of the clavicles allowed for moderate acceleration (TA = 1:25 min, ICC ≥ 0.71). Conclusions: The results demonstrate that reliable multi-factorial age estimation based on MRI of the hand, wisdom teeth and the clavicles can be performed using images acquired with a total acquisition time of 4 min.

23 December 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
MSMartin Soellradl
Martin Soellradl
ALAndreas Lesch
Andreas Lesch
JSJohannes Strasser
Johannes Strasser
LPLukas Pirpamer
Lukas Pirpamer
RSRudolf Stollberger
Rudolf Stollberger
CLChristian Langkammer
Christian Langkammer
Purpose: To model and correct the dephasing effects in the gradient‐echo signal for arbitrary RF excitation pulses with large flip angles in the presence of macroscopic field variations.Methods: The dephasing of the spoiled 2D gradient‐echo signal was modeled using a numerical solution of the Bloch equations to calculate the magnitude and phase of the transverse magnetization across the slice profile. Additionally, regional variations of the transmit RF field and slice profile scaling due to macroscopic field gradients were included. Simulations, phantom, and in vivo measurements at 3 T were conducted for and myelin water fraction (MWF) mapping.Results: The influence of macroscopic field gradients on and myelin water fraction estimation can be substantially reduced by applying the proposed model. Moreover, it was shown that the dephasing over time for flip angles of 60° or greater also depends on the polarity of the slice‐selection gradient because of phase variation along the slice profile.Conclusion: Substantial improvements in accuracy and myelin water fraction mapping coverage can be achieved using the proposed model if higher flip angles are required. In this context, we demonstrated that the phase along the slice profile and the polarity of the slice‐selection gradient are essential for proper modeling of the gradient‐echo signal in the presence of macroscopic field variations.

10 September 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
MSMartin Soellradl
Martin Soellradl
JSJohannes Strasser
Johannes Strasser
ALAndreas Lesch
Andreas Lesch
RSRudolf Stollberger
Rudolf Stollberger
SRStefan Ropele
Stefan Ropele
CLChristian Langkammer
Christian Langkammer
Purpose: To reduce the misbalance between compensation gradients and macroscopic field gradients, we introduce an adaptive slice‐specific z‐shimming approach for 2D spoiled multi‐echo gradient‐echoe sequences in combination with modeling of the signal decay.Methods: Macroscopic field gradients were estimated for each slice from a fast prescan (15 seconds) and then used to calculate slice‐specific compensation moments along the echo train. The coverage of the compensated field gradients was increased by applying three positive and three negative moments. With a forward model, which considered the effect of the slice profile, the z‐shim moment, and the field gradient, maps were estimated. The method was evaluated in phantom and in vivo measurements at 3 T and compared with a spoiled multi‐echo gradient‐echo and a global z‐shimming approach without slice‐specific compensation.Results: The proposed method yielded higher SNR in maps due to a broader range of compensated macroscopic field gradients compared with global z‐shimming. In global white matter, the mean interquartile range, proxy for SNR, could be decreased to 3.06 s−1 with the proposed approach, compared with 3.37 s−1 for global z‐shimming and 3.52 s−1 for uncompensated multi‐echo gradient‐echo.Conclusion: Adaptive slice‐specific compensation gradients between echoes substantially improved the SNR of maps, and the signal could also be rephased in anatomical areas, where it has already been completely dephased.