Yi She

Yi She

Auto-generated profile, based on publicly available information

Yi She

School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, No.800, Dongchuan Road, Minhang District, Shanghai, China, Shanghai, 200240, CHINA

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2025 in Physiological Measurement
Verified
Journal Article
Closed access
YSYi She
Yi She
ZJZeyi Jiang
Zeyi Jiang
QLQin Liu
Qin Liu
SQSirui Qiao
Sirui Qiao
YMYixin Ma
Yixin Ma
Objective. Electrical impedance tomography (EIT) generates cross-sectional images through non-invasive impedance measurements from surface electrodes. While impedance above 200 kHz can reveal intracellular properties, most existing EIT images are published at frequencies below 200 kHz. When frequencies exceed 200 kHz, the accuracy of impedance measurements declines due to the distributed circuit parameters such as parasitic capacitance, on-resistance of switch and the series inductance, with a more significant impact on larger impedance. To overcome this limitation, this paper proposes an approach to enhance the precision of impedance measurement through self-identification of distributed parameter. Approach. Firstly, the distributed circuit parameters are identified via correction measurements of precision resistances in the frequency range from 5 kHz to 1 MHz; then, the circuit is accurately modeled; finally, transfer impedance measurements during imaging process are corrected using the established circuit model. Main results. The distributed circuit parameter self-identification method was verified through a goodness-of-fit test, confirming the consistency between the model’s predicted values and the actual values of the component. The test results indicate that at 1 MHz, the relative residuals follow a right-skewed distribution with an average value of 0.08%, which demonstrates high model accuracy. At 1 MHz, the relative error after correction for the 499 Ω precision resistor measurement is reduced by 12.01%, and for the 56 pF precision capacitor in parallel with 249 Ω, the relative error after correction is 0.46%. Significance. The proposed method can extend the frequency range of EIT and other impedance technologies from below 200 kHz to up to 1 MHz, while ensuring good measurement accuracy.