14 April 2022 in IEEE Access
This article compares two strategies for seamless (re)connection of grid-forming inverters to a microgrid powered by droop-controlled inverters. While an incoming inverter must be synced to the microgrid, seamless syncing and power-sharing are technical challenges for grid-forming inverters. In the first strategy, called the output-sync method, an incoming inverter is synced to the microgrid, and then the circuit breaker is closed for power-sharing. In the second strategy, called the controller-sync method, the inverter initially contributes at zero power following the microgrid frequency, and then the controller is transferred to the mode of power-sharing. Remarkably, the circuit breaker can be kept closed during the syncing process using the controller-sync method as the inverter starts from zero power contribution. In this novel strategy, two controller sets run in parallel, i.e., two parallel control paths are in place for obtaining the magnitude and the phase angle of the PWM reference signal. These parallel paths are synced for seamless transitions when only one of them is engaged to generate the PWM reference signal. The efficacy of these control strategies has been tested in a hardware setup of a microgrid fed by two 5kVA 208V droop-controlled inverters, and the results are presented in this article. This article is also accompanied by a video clip demonstrating the performance of the output-sync and controller-sync methods in the laboratory.
16 May 2019 in IET Generation, Transmission & Distribution
The focus of this work is to analyse the performance of automatic generation control (AGC) of two area four units interconnected deregulated power system for implementing modified sine cosine algorithm (MSCA) to design the conventional PID and fuzzy‐PID (FPID) controllers. Each area consists of thermal generating unit with reheat turbine and a gas generating unit. Thermal generating units of both areas are employed with appropriate generation rate constraint. At first, sine cosine algorithm (SCA) is modified to implement MSCA technique and superiority of MSCA is proved over SCA using four benchmark functions. Then the work is extended to design the conventional PID and FPID controllers using both the algorithms. Three different situations of deregulated markets are considered. For the design of optimal controller gains integral time absolute error is taken as the objective function. To analyse the dynamic behaviour of the deregulated power system undershoot, overshoot and settling time are considered as transient parameters. After the analysis, it is found that MSCA‐based FPID controller exhibits a better transient response in terms of less undershoot, overshoot and settling time. Robustness analysis is performed by varying some of the important parameters of the power system to show the proposed FPID controller is less sensitive to parametric variations.
29 March 2019 in IEEE Systems Journal
26 July 2019 in IET Generation, Transmission & Distribution
This study presents the application of non‐linear disturbance observer (NDO) for automatic generation control of interconnected thermal area power systems considering generation rate constraints. In this work, any change in electrical power arising in the system due to either load change or change in power output of intermittent renewable energy sources is called a disturbance. This disturbance is estimated using an NDO and the same is rejected by giving an equivalent command to the governor of thermal power units to maintain a power balance in the system; thereby maintaining frequency and tie‐line power flows in each area of an interconnected power system. The analysis is presented on a two‐area power system and it is shown that the proposed control scheme effectively mitigates any active power imbalance in the system not only for normal operations but also when there is large communication delay in the system. The key advantages of the proposed scheme not only include faster frequency and tie‐line power control but also reduced control efforts as compared to other established control schemes. Furthermore, the proposed scheme requires the optimisation of only one control parameter in each area. Therefore, the scheme gives away the requirement of complex optimisation algorithms.
23 January 2024 in IEEE Transactions on Industry Applications
Grid-interactive inverters are mainly employed to optimize power injection while synchronizing with the grid's frequency and using the phase angle as the reference point. In certain circumstances, these inverters might be required to sustain power in an isolated grid segment. To achieve this, they need to generate reference points internally and collaboratively share the power load of the islanded segment, known as a microgrid. This article presents a self-governing control architecture for inverters that autonomously detect grid reconnection and islanding events, switching between grid-following (GFL) and grid-forming (GFM) modes without relying on data communication or supervisory controllers. The proposed control architecture employs a unique control-sync technique in which two sets of parallel control paths with minimal control loops are used for GFL and GFM modes of operations. Herein, while one set of control paths is engaged to generate the pulse-width modulated (PWM) signals, the other set synchronizes in the background. This ensures seamless transitions between GFL and GFM modes of operation. The efficacy of the proposed autonomous control scheme is validated through a hardware setup comprising a 30 kVA grid emulator and three 5 - 10 kVA, 208V three-phase inverters. The experiment results confirm that inverters with the proposed controller can detect grid reconnection and islanding events and autonomously switch between GFL and GFM modes.
1 February 2019 in IEEE Access
This paper presents an application of power line communication (PLC) as a viable solution for frequency regulation in a smart microgrid. The microgrid under consideration comprises of a diesel generator with a frequency controller and another synchronous generator operating in constant power mode. Frequency regulation is achieved in the microgrid by communicating the frequency deviation (information) from the control center to the diesel generator using PLC. The information received at the other end is used for frequency regulation. A simple yet effective M-ary amplitude-shift keying (ASK) modulation based PLC system is proposed for information transmission. A comparative analysis of M-ary ASK and M-ary frequency-shift keying (FSK) based PLC systems is also presented. Approximate closed-form expressions for the average symbol error rate (SER) and the average achievable rate are derived for both the PLC systems assuming that the PLC channel coefficients and the additive impulsive noise samples are derived from a lognormal distribution and a Bernoulli-Gaussian process, respectively. Results show thatM-ary ASK is a better choice for PLC thanM-ary FSK. Further, the delay introduced in the control loop while using the proposed PLC system is negligible, and therefore the stability of the microgrid is also ensured.