Chuan Qin

Chuan Qin

Auto-generated profile, based on publicly available information

Chuan Qin

School of Electrical and Power Engineering, Hohai University, Nanjing, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 January 2020 in IEEE Access
Verified
Journal Article
Open access
HHH. Huang
H. Huang
Ping JUPing JU
Ping JU
YJYuqing Jin
Yuqing Jin
XYXiaoming Yuan
Xiaoming Yuan
CQC. Qin
C. Qin
XZX. Zang
X. Zang
With the increasing integration of renewable generation, many power grids have gradually formed AC–DC hybrid systems. Abnormal operations, such as DC blocking faults and generation trips, have led to several incidents of large frequency deviations. However, current simulation methods result in large errors when estimating the frequency regulation capacity of the system. This paper proposes a generic system frequency-response (SFR) model that can be used to estimate the dynamic frequency behavior of modern large-scale power systems. The limitations of the classical SFR model is first analyzed. Second, a generic SFR model with a more reasonable structure is presented, and the parameter-determination strategy is proposed using both the dynamic and steady-state data. Then, the generic SFR model is built and verified by a simulation case. Finally, a generic SFR model with satisfactory accuracy is established for the power grid in East China based on the measured disturbance data. The results show that the proposed model is promising for broad potential applications.

15 August 2025 in IEEE Access
Verified
Journal Article
Open access
CQChuan Qin
Chuan Qin
YTYing Tang
Ying Tang
WLWei Li
Wei Li
AJAnni Jiang
Anni Jiang
Feng WuFeng Wu
Feng Wu
Wave energy converters have recently attracted significant attention in control methodology. The complex and variable marine environment makes modeling difficult, thus requiring model-free control methods. To maximize power capture while satisfying physical constraints, this study proposes a model-free control method based on Deep Q-Network (DQN), incorporating field weakening optimization (FWO) mechanism. The DQN-based control primarily optimizes the damping and stiffness coefficients, then the field weakening optimization determines the optimal output under linear/nonlinear constraints. Experimental results show that the proposed FWO enhances power capture by 37%-65% under various sea conditions while extending the operational speed range by 10%. Moreover, compared with resistive control and MPC, the DQN-FWO method improves power capture by 330% and 70% respectively, demonstrating validated effectiveness for maximal power extraction.

1 June 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
CQChuan Qin
Chuan Qin
YWYinan Wang
Yinan Wang
WDWenle Ding
Wenle Ding
YJYuqing Jin
Yuqing Jin
TJTingyu Jiang
Tingyu Jiang
PJPing Ju
Ping Ju
Net load profiles have become more volatile and sensitive to meteorological conditions due to the rapid increase in distributed photovoltaic (PV) penetration and the ongoing change in electricity consumption behavior. However, system operators cannot directly observe key components embedded in net load measurements, such as behind-the-meter (BTM) PV generation and temperature-sensitive load (TSL). This lack of observability limits accurate attribution of load variations and the assessment of dispatchable potential. Therefore, this paper proposes an unsupervised disaggregation method that relies only on net load measurements and exogenous meteorological inputs to simultaneously decompose net load into BTM PV generation, TSL, and base load (BL). The method is further designed to explicitly address the practical identifiability issue inherent in unsupervised joint disaggregation of multiple components from net load. Prior constraints on the relative peak magnitudes of TSL and BL are first derived from a linear model built with net load and meteorological data. A three-branch neural network with a scale-and-sum aggregation structure is then developed to estimate the three components using component-specific features and to reconstruct net load. The network is trained end-to-end using a regression loss between the reconstructed and observed net load. Case studies demonstrate that the proposed method yields more accurate estimates of BTM PV generation and more physically consistent estimates of TSL than existing unsupervised methods. It also demonstrates favorable practical identifiability by producing stable and reliable disaggregation results across repeated runs, while enabling accurate short-term forecasting of net load and all three components.

22 July 2026 in Electric Power Systems Research
Verified
Journal Article
Closed access
YWYuchao Wang
Yuchao Wang
CQChuan Qin
Chuan Qin
CWCan Wan
Can Wan
Ping JUPing JU
Ping JU

29 April 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
YWYuchao Wang
Yuchao Wang
CQChuan Qin
Chuan Qin
CWCan Wan
Can Wan
PJPing Ju
Ping Ju
The increasing penetration of renewable energy has transformed modern power systems into weak grids with low inertia, significantly intensifying the coupling between frequency and voltage. The traditional decoupled control paradigm, which allocates active power for frequency regulation and reactive power for voltage control, may fail to capture these critical cross-influences. To address this issue, this paper proposes a comprehensive framework for quantifying the frequency-voltage coupling strength and assessing the joint security region. First, a linearized coupling model incorporating source regulation, load response, and network impedance characteristics is established. Then, a novel frequency-voltage coupling strength index is proposed utilizing relative gain array theory. Furthermore, the concepts of the frequency-voltage coupled response trajectory are developed through linear mapping, where synthetic vectors are utilized to mathematically characterize the coupled response domain. Ultimately, an active-reactive input perturbation region is constructed to ensure joint frequency-voltage security. Analytical results reveal that the coupling strength is significantly more pronounced at load nodes and within weak grid regions. This intensified coupling fundamentally alters the coupled trajectories, distorts the coupled regions, and severely compresses the secure input power disturbance boundaries.