Ony Asrarul Qudsi

Ony Asrarul Qudsi

Auto-generated profile, based on publicly available information

Ony Asrarul Qudsi

Politeknik Elektronika Negeri Surabaya, Indonesia

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2022 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Verified
Journal Article
Open access
PDF file
FIFahmi Ahyar Izzaqi
Fahmi Ahyar Izzaqi
NWNovie Ayub Windarko
Novie Ayub Windarko
OQOny Asrarul Qudsi
Ony Asrarul Qudsi
The inverter has been attracting researchers for their application in renewable energy. So far, multilevel inverter is considered as low distortion class, which produces multilevel output voltage imitating a pure sine waveform. However, the needs for free distortion of output voltage have been motivating to improve multilevel pulse width modulation PWM generation method. In this paper, the modified PWM technique is proposed to reduce the voltage total harmonics distortion (THD) of multilevel inverter. This modulation technique is then applied to control a single-phase threelevel neutral point clamped multilevel inverter (NPC-MLI). Grey wolf optimizer (GWO) algorithm is utilized to generate optimal amplitude and phase shift of modified reference signal. The GWO algorithm is then compared with other optimization algorithms such as differential evolution (DE), human psychology optimization (HPO), and particle swarm optimization (PSO) to evaluate their performance in harmonic minimization. The performance of the proposed work is validated through simulation and experimentation on a prototype. The results show that the modified PWM technique optimized with GWO can reduce THD on NPC-MLI output voltage.

11 December 2024 in IET Energy Systems Integration
Verified
Journal Article
Open access
OQOny Asrarul Qudsi
Ony Asrarul Qudsi
ASAdi Soeprijanto
Adi Soeprijanto
APArdyono Priyadi
Ardyono Priyadi
Enhancing the stability of the Virtual Synchronous Generator (VSG) under transient conditions has become a new challenge for VSG operation. This paper presents the design of a Virtual Power System Stabiliser (VPSS) with virtual inertia calculations for the stability enhancement of the VSG system under transient conditions. The virtual inertia is calculated by considering the transient conditions resulting from a three‐phase ground fault and the allowable phase margin in the VSG. This aims to prevent the coupling effect, which can cause the active power loop control and reactive power loop control to operate non‐independently. Subsequently, the VPSS is specifically designed based on the determined virtual inertia characteristics. The VPSS design is developed by taking into account the phase angle shift of the VSG. The proposed combination of virtual inertia and VPSS is capable of providing accurate compensation for phase angle changes under transient conditions. To evaluate the performance of the proposed virtual inertia and VPSS, a system‐level VSG model is used to thoroughly analyse the system's performance. Based on the results and analysis, it is shown that the control strategy utilising the combination of virtual inertia and the proposed VPSS design can improve VSG stability under transient conditions.

26 August 2020
Verified
Conference Paper
Closed access
SSSujono Sujono
Sujono Sujono
ISIndhana Sudiharto
Indhana Sudiharto
OQOny Asrarul Qudsi
Ony Asrarul Qudsi
this paper presents the reduction of unbalanced load in the three-phase system using the Distribution Static Compensator (D-STATCOM) and Synchronous Reference Frame Theory (SRFT) as a control algorithm. The D-STATCOM is an active shunt compensator and separates with an inductor or coupling transformer. The functions of D-STATCOM are improving power quality, mitigating voltage sag/swell, and reducing the percentage of unbalanced load in the electricity distribution system. SRFT or DQ0 theory is transforming the three-phase ABC components to direct and quadrature components to simplify calculations. The transformation produces a DC signal in a steady-state condition. The inverse of the DQ0 component produces ABC components and the input signal to the Voltage Source Converter (VSC). This simulation used Simulink/MATLAB with an inductive resistive load. The result is a reducing percentage of current unbalance within 5.12% to 7.386%.

6 October 2025 in Engineering, Technology & Applied Science Research
Verified
Journal Article
Open access
PDF file
OQOny Asrarul Qudsi
Ony Asrarul Qudsi
ASAdi Soeprijanto
Adi Soeprijanto
APArdyono Priyadi
Ardyono Priyadi
Stability enhancement in microgrid systems poses significant challenges, especially with high penetration of inverter-based resources. This paper proposes the integration of Virtual Synchronous Generators (VSGs) into microgrids to provide additional virtual inertia, thereby improving system stability during disturbances. A quantitative transient stability assessment based on Critical Clearing Time (CCT) is introduced to comprehensively evaluate system dynamics with VSG integration. CCT serves as a practical metric for determining the maximum allowable fault-clearing time to maintain stability, with the CCT value derived through fault trajectory analysis using the fourth-order Runge-Kutta numerical method. Resulting trajectories are classified as Stable Trajectory (ST) or Unstable Trajectory (UT) based on post-fault system response. The study is conducted on a modified IEEE 9-bus microgrid system comprising three diesel generators, with VSG integration modeled under two penetration scenarios: 11% and 29%. Simulation results show that VSG integration significantly enhances transient stability margins. However, system response is highly sensitive to fault location and duration, underscoring the need for careful system planning.

1 January 2026 in IET Energy Systems Integration
Verified
Journal Article
Open access
OQOny Asrarul Qudsi
Ony Asrarul Qudsi
ASAdi Soeprijanto
Adi Soeprijanto
APArdyono Priyadi
Ardyono Priyadi
FSFiras Quthbi Sidqi
Firas Quthbi Sidqi
Transient stability in Dispatchable Virtual Oscillator Control (dVOC) during interconnection operations in microgrid systems remains a significant challenge. This paper proposes a Synergistic Phase‐Damping Strategy (SPDS) that integrates phase compensation and virtual damping within the dVOC control framework to improve transient stability. The proposed method is validated on a 20‐kV medium‐voltage microgrid comprising three 5‐MW dVOC‐based grid‐forming inverters under three‐phase‐to‐ground fault conditions. The phase compensator mitigates switching‐induced delays in active and reactive power regulation, while the virtual damping mechanism suppresses oscillations through high‐pass‐filtered current feedback. Simulation results demonstrate that the proposed SPDS reduces the post‐fault oscillation frequency from 48 to 17 Hz, shortens the oscillation duration from 200 to 95 ms, and decreases voltage/current recovery times from approximately 89–24 ms compared with conventional dVOC. Furthermore, the proposed strategy improves active and reactive power stabilisation while maintaining stable voltage regulation throughout fault recovery. These results confirm that SPDS significantly enhances the robustness and transient performance of dVOC‐based inverters in medium‐voltage microgrid applications.

2 September 2026 in Electrical Engineering & Electromechanics
Verified
Journal Article
Open access
PDF file
OQO. A. Qudsi
O. A. Qudsi
EPE. Purwanto
E. Purwanto
STS. M. I. Taufik
S. M. I. Taufik
Mentari Putri JatiMentari Putri Jati
Mentari Putri Jati
Introduction. Bearing faults in induction motors are one of the primary causes of performance degradation and unexpected failures in industrial systems. Early fault detection remains challenging because conventional protection systems generally respond only after severe damage occurs. In addition, motor current signals exhibit nonlinear and complex characteristics, requiring advanced analysis techniques for accurate fault identification. Problem. Existing fault diagnosis methods often suffer from limited classification accuracy, dependency on specific operating conditions, and insufficient integration between spectral feature extraction and adaptive classification techniques. Goal. To develop a non-invasive bearing fault classification method based on current spectrum analysis and artificial neural network (ANN) for induction motor condition monitoring. Methodology. The proposed method utilizes fast Fourier transform (FFT) to transform motor current signals from the time domain into the frequency domain for spectral feature extraction. The extracted features are then processed using principal component analysis (PCA) for dimensionality reduction before being used as inputs to the ANN classifier. Experimental testing is conducted under 3 bearing conditions, namely normal, 7-ball fault, and 6-ball fault conditions, using 50 datasets for each condition. Results. The results demonstrate that the proposed method successfully identifies bearing conditions with high classification accuracy and strong separation characteristics in the PCA space. FFT analysis also reveals consistent spectral changes corresponding to fault severity, particularly in sideband components and energy distribution patterns. Scientific novelty. This work integrates FFT-based current spectrum analysis, PCA-based feature reduction, and ANN classification into a unified non-invasive diagnosis framework for bearing fault detection. Practical value. The proposed approach provides a simple, adaptive, and reliable solution for early bearing fault detection without requiring additional mechanical sensors, making it suitable for industrial condition monitoring applications. References 32, tables 4, figures 7.