Noura Bettaieb

Noura Bettaieb

Auto-generated profile, based on publicly available information

Noura Bettaieb

National Engineering School of Sfax

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2020 in Journal of Pipeline Systems Engineering and Practice
Verified
Journal Article
Closed access
NBNoura Bettaieb
Noura Bettaieb
ETEzzeddine Haj Taieb
Ezzeddine Haj Taieb
Economic and efficient transient control measures are always required to ensure safe and performant operation of water distribution networks (WDNs). This study presents extensive numerical investigations of some cost-effective water hammer control strategies in pumping stations. To this end, an abrupt stoppage of pumps was considered for the numerical investigations because this event is likely to generate high transient flow disturbances in WDNs. The transient analysis was conducted using a MATLAB code based on the method of characteristics with linear integration, which is used to discretize the governing momentum and continuity equations. The considered cost-effective water hammer strategies were based on the single and combined usage of flywheels, check valves, and inline valves. Through a detailed numerical study, it was demonstrated that the performance of larger flywheels is relatively limited considering that pumps with higher moments of inertia engender extra costs in terms of space and starting energy. Alternatively, additional water hammer devices should be introduced in the pump station. It was evinced that single usage of check valves guarantees full protection of the pumps; however, it generates an additional severe water hammer effect on the pipeline integrity following the closure. On the contrary, joint use of check valves and an inline valve with an optimized closure rate resulted in a remarkable transient pressure attenuation. Results of this study prove that in some cases, a convenient combination of simple water hammer control devices can alleviate remarkably the transient pressure disturbances in WDNs without the need for more expensive and sophisticated anti-ram devices.

15 October 2019 in Journal of Theoretical and Applied Mechanics
Verified
Journal Article
Open access
NBNoura Bettaieb
Noura Bettaieb
ICIssa Chalghoum
Issa Chalghoum
ESElaoud Sami
Elaoud Sami
ETEzzeddine Hadj Taieb
Ezzeddine Hadj Taieb
In this work, the response of a PE100 pipe under transient events following pump failure is numerically investigated. The developed numerical model was based on the generalized Kelvin-Voigt model and the Vitkovsky et al. formulation. The method of characteristics (MOC) was used for numerical...


25 November 2017 in Lecture Notes in Mechanical Engineering
Verified
Book Chapter
Closed access
PDF file
NBNoura Bettaieb
Noura Bettaieb
ICIssa Chalghoum
Issa Chalghoum
ESElaoud Sami
Elaoud Sami
ETEzzeddine Hadj Taieb
Ezzeddine Hadj Taieb

4 September 2018
Verified
Book Chapter
Closed access
PDF file
LTLamjed Hadj Taieb
Lamjed Hadj Taieb
MGMed Amine Guidara
Med Amine Guidara
NBNoura Bettaieb
Noura Bettaieb
SASami El Aoud
Sami El Aoud
ETEzzeddine Hadj Taieb
Ezzeddine Hadj Taieb

25 November 2017
Verified
Book Chapter
Closed access
PDF file
KNKchaou Nouha
Kchaou Nouha
ESElaoud Sami
Elaoud Sami
CIChalghoum Issa
Chalghoum Issa
NBNoura Bettaieb
Noura Bettaieb