Mickael Tanter
Auto-generated profile, based on publicly available information

Mickael Tanter

Physics for Medicine, ESPCI, INSERM, CNRS, PSL University

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 August 2004 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
JBJ. Bercoff
J. Bercoff
MTM. Tanter
M. Tanter
MFM. Fink
M. Fink
Supersonic shear imaging (SSI) is a new ultrasound-based technique for real-time visualization of soft tissue viscoelastic properties. Using ultrasonic focused beams, it is possible to remotely generate mechanical vibration sources radiating low-frequency, shear waves inside tissues. Relying on this concept, SSI proposes to create such a source and make it move at a supersonic speed. In analogy with the "sonic boom" created by a supersonic aircraft, the resulting shear waves will interfere constructively along a Mach cone, creating two intense plane shear waves. These waves propagate through the medium and are progressively distorted by tissue heterogeneities. An ultrafast scanner prototype is able to both generate this supersonic source and image (5000 frames/s) the propagation of the resulting shear waves. Using inversion algorithms, the shear elasticity of medium can be mapped quantitatively from this propagation movie. The SSI enables tissue elasticity mapping in less than 20 ms, even in strongly viscous medium like breast. Modalities such as shear compounding are implementable by tilting shear waves in different directions and improving the elasticity estimation. Results validating SSI in heterogeneous phantoms are presented. The first in vivo investigations made on healthy volunteers emphasize the potential clinical applicability of SSI for breast cancer detection.

21 April 2009 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
GMGabriel Montaldo
Gabriel Montaldo
MTMickaël Tanter
Mickaël Tanter
JBJérémy Bercoff
Jérémy Bercoff
NBNicolas Benech
Nicolas Benech
MFMathias Fink
Mathias Fink
The emergence of ultrafast frame rates in ultrasonic imaging has been recently made possible by the development of new imaging modalities such as transient elastography. Data acquisition rates reaching more than thousands of images per second enable the real-time visualization of shear mechanical waves propagating in biological tissues, which convey information about local viscoelastic properties of tissues. The first proposed approach for reaching such ultrafast frame rates consists of transmitting plane waves into the medium. However, because the beamforming process is then restricted to the receive mode, the echographic images obtained in the ultrafast mode suffer from a low quality in terms of resolution and contrast and affect the robustness of the transient elastography mode. It is here proposed to improve the beamforming process by using a coherent recombination of compounded plane-wave transmissions to recover high-quality echographic images without degrading the high frame rate capabilities. A theoretical model is derived for the comparison between the proposed method and the conventional B-mode imaging in terms of contrast, signal-to-noise ratio, and resolution. Our model predicts that a significantly smaller number of insonifications, 10 times lower, is sufficient to reach an image quality comparable to conventional B-mode. Theoretical predictions are confirmed by in vitro experiments performed in tissue-mimicking phantoms. Such results raise the appeal of coherent compounds for use with standard imaging modes such as B-mode or color flow. Moreover, in the context of transient elastography, ultrafast frame rates can be preserved while increasing the image quality compared with flat insonifications. Improvements on the transient elastography mode are presented and discussed.

25 November 2015 in Nature
Verified
Journal Article
Closed access
CEClaudia Errico
Claudia Errico
JPJuliette Pierre
Juliette Pierre
SPSophie Pezet
Sophie Pezet
YDYann Desailly
Yann Desailly
ZLZsolt Lenkei
Zsolt Lenkei
MTMickael Tanter
Mickael Tanter

30 April 2015 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
CDCharlie Demene
Charlie Demene
TDThomas Deffieux
Thomas Deffieux
MPMathieu Pernot
Mathieu Pernot
BOBruno-Felix Osmanski
Bruno-Felix Osmanski
VBValerie Biran
Valerie Biran
MTMickael Tanter
Mickael Tanter
Ultrafast ultrasonic imaging is a rapidly developing field based on the unfocused transmission of plane or diverging ultrasound waves. This recent approach to ultrasound imaging leads to a large increase in raw ultrasound data available per acquisition. Bigger synchronous ultrasound imaging datasets can be exploited in order to strongly improve the discrimination between tissue and blood motion in the field of Doppler imaging. Here we propose a spatiotemporal singular value decomposition clutter rejection of ultrasonic data acquired at ultrafast frame rate. The singular value decomposition (SVD) takes benefits of the different features of tissue and blood motion in terms of spatiotemporal coherence and strongly outperforms conventional clutter rejection filters based on high pass temporal filtering. Whereas classical clutter filters operate on the temporal dimension only, SVD clutter filtering provides up to a four-dimensional approach (3D in space and 1D in time). We demonstrate the performance of SVD clutter filtering with a flow phantom study that showed an increased performance compared to other classical filters (better contrast to noise ratio with tissue motion between 1 and 10mm/s and axial blood flow as low as 2.6 mm/s). SVD clutter filtering revealed previously undetected blood flows such as microvascular networks or blood flows corrupted by significant tissue or probe motion artifacts. We report in vivo applications including small animal fUltrasound brain imaging (blood flow detection limit of 0.5 mm/s) and several clinical imaging cases, such as neonate brain imaging, liver or kidney Doppler imaging.

1 May 2013 in Diagnostic and Interventional Imaging
Verified
Journal Article
Closed access
JGJean-luc Gennisson
Jean-luc Gennisson
TDT. Deffieux
T. Deffieux
MFM. Fink
M. Fink
MTM. Tanter
M. Tanter

3 July 2011 in Nature Methods
Verified
Journal Article
Closed access
EMEmilie Macé
Emilie Macé
GMGabriel Montaldo
Gabriel Montaldo
ICIvan Cohen
Ivan Cohen
MBMichel Baulac
Michel Baulac
MFMathias Fink
Mathias Fink
MTMickael Tanter
Mickael Tanter