Yusak Tanoto

Yusak Tanoto

Auto-generated profile, based on publicly available information

Yusak Tanoto

Electrical Engineering Department, Petra Christian University, Indonesia

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications


2 January 2024 in International Journal of Renewable Energy Development
Verified
Journal Article
Open access
PDF file
YTYusak Tanoto
Yusak Tanoto
GBGregorius Satia Budhi
Gregorius Satia Budhi
SMSean Frederick Mingardi
Sean Frederick Mingardi
Clustering-based assessment of solar irradiation and temperature attributes for PV power generation site selection: A case of Indonesia’s Java-Bali region

5 March 2026 in International Journal of Renewable Energy Development
Verified
Journal Article
Open access
PDF file
YTYusak Tanoto
Yusak Tanoto
LDLeonardo Diprasetya
Leonardo Diprasetya
NENelson Jr Herbabuena Enano
Nelson Jr Herbabuena Enano
HWHeri Saptono Warpindyasmoro
Heri Saptono Warpindyasmoro
Wind energy represents a promising resource for accelerating the transition to renewable energy and meeting global net-zero emission targets. While wind turbines have generated considerable amounts of electricity in specific regions of four-season countries, their potential in low-wind countries is generally limited, thereby inhibiting further investigation. However, advancements in wind turbine design and wind resource databases have provided new opportunities for assessing utility-scale wind energy potential. Therefore, this study assessed the potential for utility-scale wind power generation in low-wind regions of Indonesia's Java–Bali region. The Weibull distribution of wind speed and theoretical energy output were investigated using 10-year hourly temporal-based wind speed data collected at 100 m height from 2006 to 2015. The National Renewable Energy Laboratory (NREL) power density classification was used to identify locations for energy generation analysis under wind turbine capacities of 1, 2, and 2.5 MW. The trade-offs between the average energy output over ten years and capacity factors were also considered. The results showed that the Ujungjaya area in Pandeglang Regency, Banten Province, has the potential to produce an estimated 13,916 MWh of energy per year using the 2.5 MW turbine with a capacity factor of 60.5% and Weibull parameters k and c of 2.49 and 8.22, respectively. The annual wind-based electricity generation potential of selected locations revealed that low-wind regions of Indonesia should not be overlooked when strategically planning wind energy utilisation to support the sustainable energy transition. In addition, the results have important implications for including additional wind energy in the energy mix of developing countries with similar low-wind regimes.

6 March 2025 in International Journal of Renewable Energy Development
Verified
Journal Article
Open access
PDF file
YTYusak Tanoto
Yusak Tanoto
BJBrandon Sebastian Jasman
Brandon Sebastian Jasman
SAStephanus Ananda
Stephanus Ananda
The persistent reliance on fossil fuels for energy will yield enduring adverse effects on the tourism sector, particularly the hotel industry. Wind energy represents a renewable electricity source that can facilitate the transition of small-scale hotels to clean energy. The main objective of this research is to propose a methodology for evaluating the potential of wind energy to support sustainable tourism in developing nations, specifically in fulfilling the electricity requirements of small hotels. This study aims to assess and compare the potential contribution of small wind turbines to hotel energy demand by modelling a historical hourly wind dataset spanning ten years (2011-2020) and forecasting a portion of the dataset. This research selected three sites in Indonesia exhibiting varying wind energy potentials: Tepus District in Gunung Kidul Regency, Losari Beach in Makassar City, and Nusa Penida Island in Bali. This study utilises multiple linear regression to examine the impact of external variables on wind speed, and it applies Seasonal Autoregressive Integrated Moving Average (SARIMA) and Holt-Winters Exponential Smoothing (HWES) for wind speed forecasting in these three locations. The hourly and daily interval datasets analysis reveals a weak correlation between external factors and wind speed, with the HWES method identified as the most appropriate approach for modelling and forecasting wind speed, surpassing the SARIMA model by 0.309 RMSE. Forecasting results indicate that a 30-kW wind turbine could supply 8.8 - 35.3% of a small hotel's electricity consumption, depending upon the occupancy rate.

1 February 2025 in Bulletin of Electrical Engineering and Informatics
Verified
Journal Article
Open access
PDF file
YTYusak Tanoto
Yusak Tanoto
CMChristopher Marvel
Christopher Marvel
HTHanny H Tumbelaka
Hanny H Tumbelaka
Many developing countries, including Indonesia, are progressing poorly in residential rooftop photovoltaic (PV) adoption, including on-grid systems. On the customer side, the decision to implement on-grid rooftop PV or rely only on power from the utility grid has often been made without appropriate knowledge of techno-economic considerations. This includes the impression of high system costs. This paper introduces KawanSurya: PV calculator, a solar rooftop PV techno-economic application for Android mobile phones, designed to help residential customers assess the potential of installing on-grid rooftop PV systems. The tool allows users to select a specific geographic location, calculate daily load profiles, and determine available roof areas. It uses irradiance data from the PVGIS API and HOMER’s solar PV output equation to determine hourly PV output power. Simulation results for a typical 2,200 VA household show a payback period of 9.44 years or beyond, significantly influenced by electrical load profiles and bill reduction factors. A 65% bill reduction factor and similar load profile prolong the payback period, while a 0% billing reduction factor or uncompensated electricity sales may exceed the project’s lifetime.