Chu-Shik Kang

Chu-Shik Kang

Auto-generated profile, based on publicly available information

Chu-Shik Kang

Korea Research Institute of Standards and Science

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2016 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Open access
GKGeonbo Kim
Geonbo Kim
JCJ. H. Choi
J. H. Choi
HJH. S. Jo
H. S. Jo
CKC. S. Kang
C. S. Kang
Hong Joo KimHong Joo Kim
Hong Joo Kim
JSJ. H. So
J. H. So
The simultaneous measurement of heat and light signals from a 40 Ca 100 MoO 4 scintillating crystal was performed at temperatures of tens of milli-kelvin using a scintillating bolometric detector. The crystal was instrumented with a pair of low-temperature detectors, consisting of a metallic magnetic calorimeter for reading the phonon signals and a light detector based on a Ge light absorber, to simultaneously measure the scintillation light and phonon signals. This article presents the principle and performance, such as the event separation capability, of this simultaneous heat/light measurement system.

12 March 2014 in Optics Express
Verified
Journal Article
Open access
PDF file
JKJong-Ahn Kim
Jong-Ahn Kim
JKJae Wan Kim
Jae Wan Kim
TETae Bong Eom
Tae Bong Eom
JJJonghan Jin
Jonghan Jin
CKChu-Shik Kang
Chu-Shik Kang
A technique which can measure thickness variation of a moving glass plate in real-time with nanometric resolution is proposed. The technique is based on the double-slit interference of light. Owing to the nature of differential measurement scheme, the measurement system is immune to harsh environmental condition of a production line, and the measurement results are not affected by the swaying motion of the panel. With the preliminary experimental setup with scanning speed of 100 mm/s, the measurement repeatability was 3 nm for the waviness component of the thickness profile, filtered with a Gaussian filter with cutoff wavelength of 8 mm.

4 April 2011 in Applied Optics
Verified
Journal Article
Closed access
PDF file
RJRoma Jang
Roma Jang
CKChu-Shik Kang
Chu-Shik Kang
JKJong-Ahn Kim
Jong-Ahn Kim
JKJae Wan Kim
Jae Wan Kim
JKJae-Eun Kim
Jae-Eun Kim
HPHae Yong Park
Hae Yong Park
High-speed two-wavelength phase-shifting interferometry is presented. The technique is aimed at high-speed in-line inspection of spacers in liquid crystal display panels or wafer bumps where the measuring range is well determined and high-speed measurements are essential. With our test setup, the measuring range is extended to 10 μm by using two injection locked frequency scanning lasers that offer fast and equidistant phase shifting of interference fringes. A technique to determine the unwrapped phase map in a frequency scanning phase-shifting interferometry without the ordinary phase-unwrapping process is proposed.

24 April 2024 in Measurement Science and Technology
Verified
Journal Article
Closed access
JKJong-Ahn Kim
Jong-Ahn Kim
JLJae Yong Lee
Jae Yong Lee
CKChu-Shik Kang
Chu-Shik Kang
JWJae Heun Woo
Jae Heun Woo
A versatile measurement system was developed for efficient calibration of vertical angle sensors or instruments. The vertical angle measurement system (VAMS) comprises a precision rotation stage, a controller, and additional components for fixing an angle sensor or detecting angular deviation. It can generate single-axis rotation within ±120° range with a resolution of 0.01″. To detect angular deviation in angle instrument calibration, a special miniature autocollimator was developed using a diffractive optical element, providing high-precision angle measurement even with the short focal length of its lens. The performance of the VAMS was evaluated by comparing face angles of two optical polygons, measured by the VAMS and other reference systems. As typical exemplary calibrations, an electronic level and vertical angle readouts of a total station were calibrated with expanded uncertainty (k = 2) of 0.19″ and 0.51″, respectively.

6 July 2021 in Measurement Science and Technology
Verified
Journal Article
Closed access
JKJong-Ahn Kim
Jong-Ahn Kim
JLJae Yong Lee
Jae Yong Lee
CKChu-Shik Kang
Chu-Shik Kang
JWJae Heun Woo
Jae Heun Woo
An angle sensor is developed for measuring two-dimensional (2D) angular displacement. A periodic 2D dot array was generated using a diffractive optical element, and the 2D incident angle of the collimated incident beam was obtained by detecting the multiple peak positions of the 2D dot array. This strategy can reduce random error and periodic nonlinearity effects effectively, and achieve higher precision comparing with a conventional autocollimation principle. Stability of readout of a prototype sensor was evaluated as less than 0.000 3″ with averaging time of 8 s. When 2D angular displacements over ±100″ were simultaneously measured by the prototype sensor and a commercial autocollimator, the maximum deviation was less than 0.11″.

8 February 2024 in Measurement Science and Technology
Verified
Journal Article
Closed access
JKJong-Ahn Kim
Jong-Ahn Kim
JLJae Yong Lee
Jae Yong Lee
CKChu-Shik Kang
Chu-Shik Kang
JWJae Heun Woo
Jae Heun Woo
This paper presents an effective method for evaluating the geometric errors of precision translation stages. It quantifies the six degrees of freedom (6-DOF) absolute posture of a moving platform on the stage, where a phase-encoded binary scale is fixed. This evaluation is accomplished using multi-axis readings obtained from three absolute position encoders. The scale errors are compensated using a reversal method, and distances between the measurement points are obtained without the need for additional calibration processes. Therefore, the proposed method can achieve both high accuracy and efficiency, even when implemented for on-site calibration. The performance of the prototype measurement system was evaluated by measuring the 6-DOF geometrics errors of a translation stage over a 100 mm range, and the measurement results showed agreement with the reference data within ±0.3 μm and ±1.2″.