Organic Bioelectronics Laboratory Biological and Environmental Science and Engineering Division King Abdullah University of Science and Technology (KAUST) Thuwal 23955–6900 Saudi Arabia
Auto-generated profile, based on publicly available information
Victor Druet
Organic Bioelectronics Laboratory Biological and Environmental Science and Engineering Division King Abdullah University of Science and Technology (KAUST) Thuwal 23955–6900 Saudi Arabia
Poly(3,4-ethylenedioxythiophene) (PEDOT) doped with poly(styrene sulfonate) (PSS) is the most commonly used conducting polymer in organic bioelectronics. However, electrochemical capacitances exceeding the current state-of-the-art are required for enhanced transduction and stimulation of biological signals. The long-term stability of conducting polymer films during device operation and storage in aqueous environments remains a challenge for routine applications. In this work, we electrochemically synthesize a PEDOT composite comprising the water dispersible two-dimensional conducting material Ti3C2 MXene. We find that incorporating MXene as a co-dopant along with PSS leads to PEDOT:PSS:MXene films with remarkably high volumetric capacitance (607.0 ± 85.3 F cm−3) and stability (capacity retention = 78.44% ± 1.75% over 500 cycles), outperforming single dopant-comprising PEDOT films, i.e., PEDOT:PSS and PEDOT:MXene electropolymerized under the same conditions on identical surfaces. The stability of microfabricated PEDOT:PSS:MXene electrodes is evaluated under different conditions, i.e., when the films are exposed to sonication (∼100% retention over 6 min), upon immersion in cell culture media for 14 days (∆|Z| = 2.13%), as well as after continuous electrical stimulation. Furthermore, we demonstrate the use of a PEDOT:PSS:MXene electrode as an electrochemical sensor for sensitive detection of dopamine (DA). The sensor exhibited an enhanced electrocatalytic activity toward DA in a linear range from 1 µM to 100 μM validated in mixtures containing common interferents such as ascorbic acid and uric acid. PEDOT:PSS:MXene composite is easily formed on conductive substrates with various geometries and can serve as a high performance conducting interface for chronic biochemical sensing or stimulation applications.
Among the existing two-dimensional materials, MXenes, i.e. transition metal carbides, nitrides and/or carbonitrides, stand out for their excellent electrochemical properties. Due to their high charge storage capacity, metal-like conductivity, biocompatibility as well as hydrophilicity, Ti3C2Tx MXene-based inks hold great potential for scalable production of skin conformable electronics via direct printing methods. Herein, we develop an aqueous MXene ink and inkjet-print MXene films on freestanding, flexible, and conducting polymer-based substrates. These skin-adherent MXene electrodes detect electrocardiography signals with high signal-to-noise ratio while exhibiting preserved electrical performance after 1000 cycles of bending with a 50 d long shelf life in ambient conditions. We show that printed MXene films can be further functionalized to perform as multifunctional biosensing units. When integrated with a sodium (Na+) ion selective membrane, MXene electrodes detect Na+ in artificial sweat with a sensitivity of 40 mV per decade. When the films are functionalized with antibodies, they generate an electrical signal in response to a pro-inflammatory cytokine protein (interferon gamma) with a sensitivity of 3.9 mV per decade. Our findings demonstrate how inkjet-printed MXene films simplify the fabrication of next-generation wearable electronic platforms that comprise multimodal sensors.
The development of electronics adept at interfacing with the nervous system is an ever‐growing effort, leading to discoveries in fundamental neuroscience applied in clinical setting. Highly capacitive and electrochemically stable electronic materials are paramount for these advances. A systematic study is presented where copolymers based on 3,4‐ethylenedioxythiophene (EDOT) and its hydroxyl‐terminated counterpart (EDOTOH) are electropolymerized in an aqueous solution in the presence of various counter anions and additives. Amongst the conducting materials developed, the copolymer p(EDOT‐ran‐EDOTOH) doped with perchlorate in the presence of ethylene glycol shows high specific capacitance (105 F g−1), and capacitance retention (85%) over 1000 galvanostatic charge–discharge cycles. A microelectrode array‐based on this material is fabricated and primary cortical neurons are cultured therein for several days. The microelectrodes electrically stimulate targeted neuronal networks and record their activity with high signal‐to‐noise ratio. The stability of charge injection capacity of the material is validated via long‐term pulsing experiments. While providing insights on the effect of additives and dopants on the electrochemical performance and operational stability of electropolymerized conducting polymers, this study highlights the importance of high capacitance accompanied with stability to achieve high performance electrodes for biological interfacing.