Carter B. Macdonald

Carter B. Macdonald

Auto-generated profile, based on publicly available information

Carter B. Macdonald

Department of Biomedical Engineering Georgia Institute of Technology and Emory University School of Medicine Atlanta Georgia USA

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2025 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
CMCarter B. Macdonald
Carter B. Macdonald
ABAditya Bhattacharya
Aditya Bhattacharya
BRBenjamin B. Risk
Benjamin B. Risk
TZTaylor M. Zuleger
Taylor M. Zuleger
SMSagar Mandava
Sagar Mandava
CFCandace C. Fleischer
Candace C. Fleischer
Background: The effect of the positron emission tomography (PET) modality in hybrid PET/MR scanners on MR spectral quality is unclear. Purpose: To evaluate spectral quality, quantification, and repeatability of brain MR spectroscopy (MRS) acquired on PET/MR and standalone MR scanners. Study Type: Prospective. Subjects: 23 healthy adults (male/female = 11/12, age = 27 ± 11 years). Field Strength/Sequence: 3T, semi‐localized by adiabatic selective refocusing. Assessment: Single voxel MR spectra were acquired with GE Signa PET/MR and Siemens Prisma Fit MR scanners in healthy volunteers, and additionally with a GE Premier MR scanner in vitro. Spectral quality, metabolite concentrations, and repeatability were evaluated. Statistical Tests: Linear mixed models assessed signal‐to‐noise ratio (SNR), full width at half maximum (FWHM), and metabolites/total creatine (tCr). Intraclass correlation coefficients (ICCs) determined repeatability; mean squared error (MSE) evaluated accuracy of quantification. Values are reported as mean ± standard deviation. Significance was determined by p ≤ 0.05. Results: In vivo spectra acquired using the Siemens standalone MR showed significantly higher SNR (PET/MR: 118.8 ± 19.1, MR: 132.2 ± 24.4) but significantly broader FWHM (PET/MR: 7.2 ± 1.8 Hz, MR: 8.4 ± 2.5 Hz) compared to PET/MR. All metabolite ratios were significantly higher in spectra acquired on the standalone MR. Within‐session repeatability was good (ICC > 0.75), and between‐session repeatability was moderate to excellent (ICC 0.5 to > 0.90) for all metabolites in vivo. In vitro spectra acquired with the PET/MR had significantly higher SNR (329.1 ± 46.1) than the Siemens standalone MR (150.8 ± 49.3) but significantly lower than the GE standalone MR (395.9 ± 33.7). The PET/MR produced narrower FWHM (2.1 ± 0.4 Hz) than the Siemens standalone MR (4.1 ± 1.7 Hz) but broader than the GE standalone MR (1.6 ± 0.1 Hz) and lower MSE for some metabolites. Data Conclusion: MR spectral quality appears uncompromised when acquired with hybrid PET/MR compared to standalone MR.