Charlotte Hopkinson

Charlotte Hopkinson

Auto-generated profile, based on publicly available information

Charlotte Hopkinson

Univ Edinburgh, Inst Integrated Micro & Nano Syst, Sch Engn, Edinburgh EH9 3FF, Scotland

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2022 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
AEAhmet T. Erdogan
Ahmet T. Erdogan
TATarek Al Abbas
Tarek Al Abbas
NFNeil Finlayson
Neil Finlayson
CHCharlotte Hopkinson
Charlotte Hopkinson
IGIstvan Gyongy
Istvan Gyongy
RHRobert Henderson
Robert Henderson
A miniaturized 1.4 mm $\times \,\, 1.4$ mm, $128\times120$ single-photon avalanche diode (SPAD) image sensor with a five-wire interface is designed for time-resolved fluorescence microendoscopy. This is the first endoscopic chip-on-tip sensor capable of fluorescence lifetime imaging microscopy (FLIM). The sensor provides a novel, compact means to extend the photon counting dynamic range (DR) by partitioning the required bit depth between in-pixel counters and off-pixel noiseless frame summation. The sensor is implemented in STMicroelectronics 40-/90-nm 3-D-stacked backside-illuminated (BSI) CMOS process with 8- $\mu \text{m}$ pixels and 45% fill factor. The sensor capabilities are demonstrated through FLIM examples, including ex vivo human lung tissue, obtained at video rate.

14 December 2023 in Biomedical Optics Express
Verified
Journal Article
Open access
CHCharlotte Hopkinson
Charlotte Hopkinson
AMAndrew Matheson
Andrew Matheson
NFNeil Finlayson
Neil Finlayson
MTMichael Tanner
Michael Tanner
AAAhsan R. Akram
Ahsan R. Akram
RHRobert Henderson
Robert Henderson
In this work a combined fluorescence lifetime and surface topographical imaging system is demonstrated. Based around a 126 × 192 time resolved single photon avalanche diode (SPAD) array operating in time correlated single-photon counting (TCSPC) mode, both the fluorescence lifetime and time of flight (ToF) can be calculated on a pixel by pixel basis. Initial tests on fluorescent samples show it is able to provide 4 mm resolution in distance and 0.4 ns resolution in lifetime. This combined modality has potential biomedical applications such as surgical guidance, endoscopy, and diagnostic imaging. The system is demonstrated on both ovine and human pulmonary tissue samples, where it offers excellent fluorescence lifetime contrast whilst also giving a measure of the distance to the sample surface.