29 October 2022 in Journal of Shoulder and Elbow Surgery
20 July 2021 in Journal of the American Academy of Orthopaedic Surgeons
Introduction: The primary purpose of this study was to determine the number of patients who would be denied a complication-free total shoulder arthroplasty (TSA) based on implementation of body mass index (BMI) eligibility cutoffs. Methods: The National Surgical Quality Improvement Program database was queried to identify all patients who underwent primary TSA. Patient demographics and 30-day postoperative complications were compared according to BMI stratification using the Pearson chi-square test and binary logistic regression analysis adjusted for age and modified Charlson comorbidity index. A BMI eligibility criterion of ≥40 kg/m2 was used to calculate the positive predictive value (PPV) to assess the number of complication-free TSAs that would be denied to avoid a complication in a single patient. Results: A total of 23,284 patients who underwent TSA met inclusion criteria. The overall complication rate was 7.2%. Using a BMI cutoff of ≥40 kg/m2 would yield a PPV of 7% for all Major Complications. This means that 14 complication-free procedures would be denied to avoid a Major Complication. In addition, BMI ≥40 kg/m2 served as an independent risk factor for acute renal failure, pulmonary embolism, ventilator use >48 hours, and readmission. The PPV for these clinically significant complications using BMI ≥40 kg/m2 as a cutoff was 4.9%. This translates into 20 patients being denied a complication-free procedure to avoid a single clinically significant medical complication. If this policy was enforced on the 2,426 patients who exceeded BMI ≥40 kg/m2 in this study, nearly 2,307 patients would be denied the potential benefit of surgery to prevent 119 complications. Conclusion: The use of eligibility criteria for primary TSA or RSA based solely on BMI threshold values presents a potential limitation in access to care to these patients who otherwise would have a complication-free procedure. Level of evidence: Level III, prognostic, retrospective cohort study
20 January 2022 in Journal of Shoulder and Elbow Surgery
15 August 2024 in International Orthopaedics
Purpose: Fractures and dislocations of the pelvic ring are complex injuries that when treating require meticulous attention to detail and often specialized technical skill. These injuries can be the result of high-energy trauma, particularly in younger patients, or low energy trauma more often found in the elderly. Regardless of mechanism, these injuries lie on a spectrum of severity and can be treated conservatively or surgically. Percutaneous fixation under fluoroscopic guidance is the preferred standard technique when treating these fractures. This technique can be challenging for a variety of reasons including patient characteristics, intra-operative image quality, fracture morphology, among others. Methods: This retrospective study evaluated the use of intra-operative computed tomography (CT) using an O-arm imaging system for critical evaluation of fluoroscopic-guided screw placement in twenty-three patients. We retrospectively reviewed all cases of patients who were treated by three fellowship-trained orthopaedic traumatologists during a one-year span. Patients undergoing percutaneous pelvis fixation using both standard fluoroscopy and intraoperative CT with the Medtronic O-arm® (Minneapolis, MN) imaging system. Additionally, procedures performed included open reduction internal fixation (ORIF) of the pelvic ring, acetabulum, and associated extremity fractures. Results: Twenty-three patients were included in this study. On average, the use of intraoperative CT added 24.4 min in operative time. Five patients (21.7%) required implant adjustment after O-arm spin. Fourteen patients underwent additional post-operative CT. No secondary revision surgeries were attempted after any post-operative CT. Conclusions: Our study suggests that intra-operative CT scan, compared to post-operative CT scan, can be utilized to prevent take-back surgery for misplaced implants and allow for adjustment in real-time.
17 December 2021 in Global Spine Journal
Retrospective review. With increased awareness of the opioid crisis in spine surgery, the focus postoperatively has shifted to managing surgical site pain while minimizing opioid use. Numerous studies have compared outcomes and fusion status of different interbody fusion techniques; however, there is limited literature evaluating opioid consumption postoperatively between techniques. The aim of this study was to assess in-house and postoperative opioid consumption across 3 surgical techniques. Patients were stratified by technique: posterior lumbar interbody fusion (PLIF), minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF), and cortical screw (CS) instrumentation with interbody fusion. Age, ASA, BMI, depression, preoperative opioid use, EBL, and OR time were recorded and compared across surgical groups using Welch’s ANOVA and chi-square analysis. Total morphine equivalent dose (MED) was tabulated for both in-house consumption and postoperative prescriptions and was compared across surgical techniques using Welch’s ANOVA analysis, Mann Whitney U tests, and linear regression. Two hundred and thirty nine patients underwent one- or two-level posterior lumbar interbody fusion between 2016 and 2020. One hundred and twenty one patients underwent CS instrumentation, 95 underwent PLIF, and 83 underwent MIS-TLIF. There was a significantly higher percentage of patients who had a history of depression and preoperative opioid consumption in the CS group (P = .001, P = .009). CS instrumentation required significantly less total post-op opioids per kilogram bodyweight compared to MIS-TLIF and PLIF surgeries (P = .029). Patients who underwent CS instrumentation required less opioids postoperatively. CS instrumentation may be associated with less postoperative pain due to the less invasive approach, however, patient education and prescriber practice also play a role in postoperative opioid consumption.