Joao Amaro

Joao Amaro

Auto-generated profile, based on publicly available information

Joao Amaro

Instituto de Telecomunicacoes, University of Coimbra, Portugal

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2015 in Neural Processing Letters
Verified
Journal Article
Closed access
PDF file
JMJoao Maria
Joao Maria
JAJoao Amaro
Joao Amaro
Gabriel FalcaoGabriel Falcao
Gabriel Falcao
LALuís A. Alexandre
Luís A. Alexandre

1 January 2015 in Physics Procedia
Verified
Journal Article
Open access
MCMiguel Caxinha
Miguel Caxinha
EVElena Velte
Elena Velte
Mário João F S SantosMário João F S Santos
Mário João F S Santos
FPFernando Perdigão
Fernando Perdigão
JAJoão Amaro
João Amaro
Jaime Batista dos SantosJaime Batista dos Santos
Jaime Batista dos Santos
This paper addresses the use of computer-aided diagnosis (CAD) system for the cataract classification based on ultrasound technique. Ultrasound A-scan signals were acquired in 220 porcine lenses. B-mode and Nakagami images were constructed. Ninety-seven parameters were extracted from acoustical, spectral and image textural analyses and were subjected to feature selection by Principal Component Analysis (PCA). Bayes, K Nearest-Neighbors (KNN), Fisher Linear Discriminant (FLD) and Support Vector Machine (SVM) classifiers were tested. The classification of healthy and cataractous lenses shows a good performance for the four classifiers (F-measure ≥92.68%) with SVM showing the highest performance (90.62%) for initial versus severe cataract classification

11 May 2015 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
JAJoao Amaro
Joao Amaro
BYBilly Y. S. Yiu
Billy Y. S. Yiu
Gabriel FalcaoGabriel Falcao
Gabriel Falcao
Marco GomesMarco Gomes
Marco Gomes
AYAlfred Yu
Alfred Yu
Field-programmable gate arrays (FPGAs) can potentially be configured as beamforming platforms for ultrasound imaging, but a long design time and skilled expertise in hardware programming are typically required. In this article, we present a novel approach to the efficient design of FPGA beamformers for synthetic aperture (SA) imaging via the use of software-based high-level synthesis techniques. Software kernels (coded in OpenCL) were first developed to stage-wise handle SA beamforming operations, and their corresponding FPGA logic circuitry was emulated through a high-level synthesis framework. After design space analysis, the fine-tuned OpenCL kernels were compiled into register transfer level descriptions to configure an FPGA as a beamformer module. The processing performance of this beamformer was assessed through a series of offline emulation experiments that sought to derive beamformed images from SA channel-domain raw data (40-MHz sampling rate, 12 bit resolution). With 128 channels, our FPGA-based SA beamformer can achieve 41 frames per second (fps) processing throughput (3.44 × 10 8 pixels per second for frame size of 256 × 256 pixels) at 31.5 W power consumption (1.30 fps/W power efficiency). It utilized 86.9% of the FPGA fabric and operated at a 196.5 MHz clock frequency (after optimization). Based on these findings, we anticipate that FPGA and high-level synthesis can together foster rapid prototyping of real-time ultrasound processor modules at low power consumption budgets.

5 May 2016 in Journal of Real-Time Image Processing
Verified
Journal Article
Closed access
PDF file
RRRicardo Ralha
Ricardo Ralha
Gabriel FalcaoGabriel Falcao
Gabriel Falcao
JAJoao Amaro
Joao Amaro
VMVasco Mota
Vasco Mota
MAMichel Antunes
Michel Antunes
UNUrbano J. Nunes
Urbano J. Nunes

1 May 2013
Verified
Conference Paper
Closed access
JAJoao Amaro
Joao Amaro
Gabriel FalcaoGabriel Falcao
Gabriel Falcao
BYBilly Y. S. Yiu
Billy Y. S. Yiu
AYAlfred C. H. Yu
Alfred C. H. Yu
In medical ultrasound, synthetic aperture (SA) imaging is well-considered as a novel image formation technique for achieving superior resolution than that offered by existing scanners. However, its intensive processing load is known to be a challenging factor. To address such a computational demand, this paper proposes a new parallel approach based on the design of OpenCL signal processing kernels that can compute SA image formation in real-time. We demonstrate how these kernels can be ported onto different classes of parallel processors, namely multi-core CPUs and GPUs, whose multi-thread computing resources are able to process more than 250 fps. Moreover, they have strong potential to support the development of more complex algorithms, thus increasing the depth range of the inspected human volume and the final image resolution observed by the medical practitioner.