Colin J. Stephen

Colin J. Stephen

Auto-generated profile, based on publicly available information

Colin J. Stephen

Department of Physics, University of Warwick, Coventry CV4 7AL, United Kingdom

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2019 in Optica
Verified
Journal Article
Open access
PDF file
YCYu-Chen Chen
Yu-Chen Chen
BGBenjamin Griffiths
Benjamin Griffiths
LWLaiyi Weng
Laiyi Weng
SNShannon S. Nicley
Shannon S. Nicley
SIShazeaa N. Ishmael
Shazeaa N. Ishmael
JSJason M. Smith
Jason M. Smith
Atomic defects in wide-bandgap materials, such as the nitrogen-vacancy (NV) color center in diamond, show considerable promise for the development of a new generation of quantum information technologies, but progress has been hampered by the inability to produce and engineer the defects in a controlled manner. Here, we demonstrate an all-optical method for the deterministic writing of individual NV centers at selected locations with high positioning accuracy. Ultrashort pulse laser processing is used to both create and diffuse defects inside the crystal through local annealing. During the laser-annealing process, online fluorescence feedback provides a trigger to stop processing once the NV formation is detected. This method provides a new tool for the optical fabrication of engineered materials and devices for quantum technologies.

2 May 2022 in Physical Review B
Verified
Journal Article
Closed access
PDF file
BWB. D. Wood
B. D. Wood
GSG. A. Stimpson
G. A. Stimpson
JMJ. E. March
J. E. March
YLY. N. D. Lekhai
Y. N. D. Lekhai
CSC. J. Stephen
C. J. Stephen
GMG. W. Morley
G. W. Morley
Nanodiamonds containing negatively charged nitrogen vacancy centers (NV−) have applications as localized sensors in biological materials and have been proposed as a platform to probe the macroscopic limits of spatial superposition and the quantum nature of gravity. A key requirement for these applications is to obtain nanodiamonds containing NV− with long spin coherence times. Using milling to fabricate nanodiamonds processes the full 3D volume of the bulk material at once, unlike etching pillars, but has, up to now, limited NV− spin coherence times. Here, we use natural isotopic abundance nanodiamonds produced by Si3N4 ball milling of chemical vapor deposition grown bulk diamond with an average single substitutional nitrogen concentration of 121ppb. We show that the electron spin coherence times of NV− centers in these nanodiamonds can exceed 400 μs at room temperature with dynamical decoupling. Scanning electron microscopy provides images of the specific nanodiamonds containing NV− for which a spin coherence time was measured.

3 December 2019 in Physical Review Applied
Verified
Journal Article
Open access
PDF file
CSC. J. Stephen
C. J. Stephen
BGB. L. Green
B. L. Green
YLY. N. D. Lekhai
Y. N. D. Lekhai
LWL. Weng
L. Weng
PHP. Hill
P. Hill
GMG. W. Morley
G. W. Morley
Nitrogen-vacancy centers (NVCs) in diamond show promise for quantum computing, communication, and sensing. However, the best current method for entangling two NVCs requires that each one is in a separate cryostat, which is not scalable. We show that single NVCs can be laser written 6–15-µm deep inside of a diamond with spin coherence times that are an order of magnitude longer than previous laser-written NVCs and at least as long as naturally occurring NVCs. This depth is suitable for integration with solid immersion lenses or optical cavities and we present depth-dependent T2 measurements. 200 000 of these NVCs would fit into one diamond.

12 August 2025 in Physical Review Applied
Verified
Journal Article
Open access
ANA.J. Newman
A.J. Newman
SGS.M. Graham
S.M. Graham
CSC.J. Stephen
C.J. Stephen
AEA.M. Edmonds
A.M. Edmonds
MMM.L. Markham
M.L. Markham
GMG.W. Morley
G.W. Morley
Intraoperative measurements using magnetic sensors are a valuable technique in cancer surgery for finding magnetic tracers. Here we present a fiber-coupled nitrogen-vacancy center magnetometer capable of detecting iron oxide suspension (MagTrace™ from Endomagnetics Ltd.) used in breast cancer surgeries. Detection of an iron mass as low as 0.56 mg has been demonstrated, 100 times less than that of a recommended dose at a maximum distance of 5.8 mm. Detection of an iron concentration as low as 2.8 mg/ml has also been demonstrated, 20 times less than a recommended dose. The maximum working distance from the sensor can be as large as 14.6 mm for higher concentrations. The sensor head has a maximum diameter of 10 mm which would allow it to be used for endoscopy, laparoscopy, and intraoperative surgery.

21 November 2025 in Materials for Quantum Technology
Verified
Journal Article
Open access
AKAndrew R Kirkpatrick
Andrew R Kirkpatrick
ZMZhin Mai
Zhin Mai
CSColin J Stephen
Colin J Stephen
GJGareth S Jones
Gareth S Jones
GMGavin W Morley
Gavin W Morley
JSJason M Smith
Jason M Smith
We report the deterministic writing of single nitrogen-vacancy defects in commercially available high purity diamond using only laser processing. The positioning accuracy of the single defects is around 250 nm and about 20% of the written defects display near transform-limited optical transitions at a temperature of 5 K. The results represent a significant step towards defect-engineered devices using colour centres as coherent spin-photon interfaces for quantum technologies, and shed light on the physical mechanism for laser-induced vacancy diffusion in diamond.

1 June 2026 in American Journal of Physics
Verified
Journal Article
Open access
HWHollis Williams
Hollis Williams
ANAlex Newman
Alex Newman
SGStuart Graham
Stuart Graham
CSColin Stephen
Colin Stephen
GMGavin Morley
Gavin Morley
We present a compact, low-cost version of a nitrogen-vacancy center diamond magnetometer, where the standard green excitation laser is replaced with a high-power light-emitting diode. This modification improves safety, reduces cost, and allows the green excitation and red photoluminescence light to be viewed directly during demonstrations. Our magnetometer is simple to assemble and suitable for outreach activities and undergraduate laboratories. We show that this experimental setup can produce optically detected magnetic resonance spectra and respond to nearby magnetic objects, with a sensitivity on the order of 1 μT/Hz. Accompanying supplementary material provides details of the magnetometer construction and suggestions for student investigations to support use in teaching laboratories.