Yoojin Chung

Yoojin Chung

Auto-generated profile, based on publicly available information

Yoojin Chung

Decibel Therapeutics, Inc., Boston, MA 02215, United States

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2012 in Journal of Neurophysiology
Verified
Journal Article
Closed access
PDF file
KHKenneth E. Hancock
Kenneth E. Hancock
YCYoojin Chung
Yoojin Chung
BDBertrand Delgutte
Bertrand Delgutte
Poor sensitivity to the interaural time difference (ITD) constrains the ability of human bilateral cochlear implant users to listen in everyday noisy acoustic environments. ITD sensitivity to periodic pulse trains degrades sharply with increasing pulse rate but can be restored at high pulse rates by jittering the interpulse intervals in a binaurally coherent manner (Laback and Majdak. Binaural jitter improves interaural time-difference sensitivity of cochlear implantees at high pulse rates. Proc Natl Acad Sci USA 105: 814–817, 2008). We investigated the neural basis of the jitter effect by recording from single inferior colliculus (IC) neurons in bilaterally implanted, anesthetized cats. Neural responses to trains of biphasic pulses were measured as a function of pulse rate, jitter, and ITD. An effect of jitter on neural responses was most prominent for pulse rates above 300 pulses/s. High-rate periodic trains evoked only an onset response in most IC neurons, but introducing jitter increased ongoing firing rates in about half of these neurons. Neurons that had sustained responses to jittered high-rate pulse trains showed ITD tuning comparable with that produced by low-rate periodic pulse trains. Thus, jitter appears to improve neural ITD sensitivity by restoring sustained firing in many IC neurons. The effect of jitter on IC responses is qualitatively consistent with human psychophysics. Action potentials tended to occur reproducibly at sparse, preferred times across repeated presentations of high-rate jittered pulse trains. Spike triggered averaging of responses to jittered pulse trains revealed that firing was triggered by very short interpulse intervals. This suggests it may be possible to restore ITD sensitivity to periodic carriers by simply inserting short interpulse intervals at select times.

31 December 2013 in Journal of Neuroscience
Verified
Journal Article
Open access
PDF file
YCYoojin Chung
Yoojin Chung
KHKenneth E. Hancock
Kenneth E. Hancock
SNSung-Il Nam
Sung-Il Nam
BDBertrand Delgutte
Bertrand Delgutte
Cochlear implant (CI) listeners show limits at high frequencies in tasks involving temporal processing such as rate pitch and interaural time difference discrimination. Similar limits have been observed in neural responses to electric stimulation in animals with CI; however, the upper limit of temporal coding of electric pulse train stimuli in the inferior colliculus (IC) of anesthetized animals is lower than the perceptual limit. We hypothesize that the upper limit of temporal neural coding has been underestimated in previous studies due to the confound of anesthesia. To test this hypothesis, we developed a chronic, awake rabbit preparation for single-unit studies of IC neurons with electric stimulation through CI. Stimuli were periodic trains of biphasic pulses with rates varying from 20 to 1280 pulses per second. We found that IC neurons in awake rabbits showed higher spontaneous activity and greater sustained responses, both excitatory and suppressive, at high pulse rates. Maximum pulse rates that elicited synchronized responses were approximately two times higher in awake rabbits than in earlier studies with anesthetized animals. Here, we demonstrate directly that anesthesia is a major factor underlying these differences by monitoring the responses of single units in one rabbit before and after injection of an ultra-short-acting barbiturate. In general, the physiological rate limits of IC neurons in the awake rabbit are more consistent with the psychophysical limits in human CI subjects compared with limits from anesthetized animals.

18 May 2016 in Journal of Neuroscience
Verified
Journal Article
Open access
PDF file
YCYoojin Chung
Yoojin Chung
KHKenneth E. Hancock
Kenneth E. Hancock
BDBertrand Delgutte
Bertrand Delgutte
Although bilateral cochlear implants (CIs) provide improvements in sound localization and speech perception in noise over unilateral CIs, bilateral CI users' sensitivity to interaural time differences (ITDs) is still poorer than normal. In particular, ITD sensitivity of most CI users degrades with increasing stimulation rate and is lacking at the high carrier pulse rates used in CI processors to deliver speech information. To gain a better understanding of the neural basis for this degradation, we characterized ITD tuning of single neurons in the inferior colliculus (IC) for pulse train stimuli in an unanesthetized rabbit model of bilateral CIs. Approximately 73% of IC neurons showed significant ITD sensitivity in their overall firing rates. On average, ITD sensitivity was best for pulse rates near 80–160 pulses per second (pps) and degraded for both lower and higher pulse rates. The degradation in ITD sensitivity at low pulse rates was caused by strong, unsynchronized background activity that masked stimulus-driven responses in many neurons. Selecting synchronized responses by temporal windowing revealed ITD sensitivity in these neurons. With temporal windowing, both the fraction of ITD-sensitive neurons and the degree of ITD sensitivity decreased monotonically with increasing pulse rate. To compare neural ITD sensitivity to human performance in ITD discrimination, neural just-noticeable differences (JNDs) in ITD were computed using signal detection theory. Using temporal windowing at lower pulse rates, and overall firing rate at higher pulse rates, neural ITD JNDs were within the range of perceptual JNDs in human CI users over a wide range of pulse rates.SIGNIFICANCE STATEMENTMany profoundly deaf people wearing cochlear implants (CIs) still face challenges in everyday situations, such as understanding conversations in noise. Even with CIs in both ears, they have difficulty making full use of subtle differences in the sounds reaching the two ears [interaural time difference (ITD)] to identify where the sound is coming from. This problem is especially acute at the high stimulation rates used in clinical CI processors. This study provides a better understanding of ITD processing with bilateral CIs and shows a parallel between human performance in ITD discrimination and neural responses in the auditory midbrain. The present study is the first report on binaural properties of auditory neurons with CIs in unanesthetized animals.

5 March 2013 in Journal of the Association for Research in Otolaryngology
Verified
Journal Article
Closed access
PDF file
KHKenneth E. Hancock
Kenneth E. Hancock
YCYoojin Chung
Yoojin Chung
BDBertrand Delgutte
Bertrand Delgutte

22 October 2008 in Journal of the Association for Research in Otolaryngology
Verified
Journal Article
Closed access
PDF file
HCH. Steven Colburn
H. Steven Colburn
YCYoojin Chung
Yoojin Chung
YZYi Zhou
Yi Zhou
ABAndrew Brughera
Andrew Brughera

17 March 2025 in Trends in Hearing
Verified
Journal Article
Open access
RCRobert P. Carlyon
Robert P. Carlyon
JDJohn M. Deeks
John M. Deeks
BDBertrand Delgutte
Bertrand Delgutte
YCYoojin Chung
Yoojin Chung
MVMaike Vollmer
Maike Vollmer
RGRaymond L. Goldsworthy
Raymond L. Goldsworthy
Cochlear implant (CI) users are usually poor at using timing information to detect changes in either pitch or sound location. This deficit occurs even for listeners with good speech perception and even when the speech processor is bypassed to present simple, idealized stimuli to one or more electrodes. The present article presents seven expert opinion pieces on the likely neural bases for these limitations, the extent to which they are modifiable by sensory experience and training, and the most promising ways to overcome them in future. The article combines insights from physiology and psychophysics in cochlear-implanted humans and animals, highlights areas of agreement and controversy, and proposes new experiments that could resolve areas of disagreement.