Sirish Chandra Srinath Patloori

Sirish Chandra Srinath Patloori

Auto-generated profile, based on publicly available information

Sirish Chandra Srinath Patloori

Department of Cardiology Christian Medical College Vellore Tamilnadu India

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 September 2022 in Medical Sciences
Verified
Journal Article
Open access
PDF file
ABAditya John Binu
Aditya John Binu
SSSirish Chandra Srinath
Sirish Chandra Srinath
KCKripa Elizabeth Cherian
Kripa Elizabeth Cherian
JJJohn Roshan Jacob
John Roshan Jacob
TPThomas V Paul
Thomas V Paul
NKNitin Kapoor
Nitin Kapoor
Background: Obesity is associated with increased all-cause mortality and cardiovascular disease (CVD). An electrocardiogram (ECG) may be used to screen for subtle signs of CVD or altered cardiac morphology in the obese. Methodology: This observational cross-sectional analysed ECG changes in patients with obesity at a tertiary care centre in southern India. Results: One hundred and fifty adult patients with a mean (SD) BMI of 39.9 (6.7) kg/m2 were recruited in the study after excluding those with comorbidities (diabetes mellitus, systemic hypertension) or on chronic medications (ACE inhibitors). The cohort showed a female predominance (69.3%), with a mean (SD) age of 45.4 (11.2) years. Most patients exhibited a sinus rhythm (78%), with one patient showing features of first-degree conduction block. Sinus tachycardia was seen in 32 (21.3%) patients. We observed left and right ventricular hypertrophy in five (3.3%) and three (2%) patients, respectively. Observed ECG patterns included a prolonged QTc in 16 (10.7%) patients, inverted T-waves (mostly in the inferior leads) in 39 (26%) patients and ST-segment depression (predominantly in the lateral leads) in 14 (9.3%) patients. A greater prevalence was noted for morbid obesity. No deaths were reported in our cohort. Conclusions: The predominant ECG variations in this cohort included tachycardia, atrial enlargement, ventricular hypertrophy, conduction defects, LAD, features of ischemia or old infarction and repolarization abnormalities, with a greater prevalence in morbid obesity. Further studies are needed to assess the impact of weight reducing measures on reversibility of these changes and determine the association with outcomes in obese patients.

1 November 2017 in Indian Pacing and Electrophysiology Journal
Verified
Journal Article
Open access
ALAnandaroop Lahiri
Anandaroop Lahiri
SSSirish Chandra Srinath
Sirish Chandra Srinath
DCDavid Chase
David Chase
JRJohn Roshan
John Roshan

13 December 2019 in Indian Pacing and Electrophysiology Journal
Verified
Journal Article
Open access
PDF file
SPSakshi Parasrampuria
Sakshi Parasrampuria
SPSirish Chandra Srinath Patloori
Sirish Chandra Srinath Patloori
RKReka Karuppusami
Reka Karuppusami
DCDavid Chase
David Chase
JRJohn Roshan
John Roshan
Background: Data from large-volume centers in developed countries, using dedicated tools, show a high success rate with a good safety record for the percutaneous lead removal procedure. However, there are constraints to replicate the results in a resource-poor setting and there is limited data from India. Methods: We retrospectively analyzed lead removal procedures performed in our institution from 2008 to 2019. Results: Seventy-five patients underwent percutaneous removal of 138 leads. Of these, 44 procedures and 80 leads qualified as extraction with a median dwell time of 52.1 (IQR 28.2 - 117.2) months. Overall, 33/44 (75.0%) procedures were successful and 65/80 (81.2%) leads were successfully extracted. Manual traction was successful in the extraction of 44/57 (77.2%) leads. All leads implanted less than 2.7 years could be removed with manual traction alone. Specialized tools were used in 23 leads and 21 (91.3%) of those could be successfully extracted. Inability to use dedicated tools was an independent predictor of procedural failure (adjusted OR 14.0; 95% CI 1.8 - 110.2; p-value 0.012). Right-sided implant (adjusted OR 12.6; 95% CI 1.3 - 119.5; p-value 0.027) was also independently associated with failure. There was 1 death (1.3%) and minor complications occurred in 6 (8.0%) patients. Conclusions: In a resource-limited setting, percutaneous lead extraction of predominantly pacemaker leads by manual traction methods achieved success in extracting about three-fourths of the leads. Inability to use specialized tools was the main factor limiting success. The complication rate was low.

10 January 2023 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
AMAnand Manickavasagam
Anand Manickavasagam
SGSiva Nageswara Rao Guttikonda
Siva Nageswara Rao Guttikonda
DBDinakar Bootla
Dinakar Bootla
SPSirish Chandra Srinath Patloori
Sirish Chandra Srinath Patloori
AJAshish Jain
Ashish Jain
JJJohn R. Jacob
John R. Jacob

1 February 2021 in Journal of Arrhythmia
Verified
Journal Article
Open access
PDF file
AMAnand Manickavasagam
Anand Manickavasagam
KNKrishnakumar Nair
Krishnakumar Nair
SPSirish Chandra Srinath Patloori
Sirish Chandra Srinath Patloori
DCDavid Chase
David Chase
JRJohn Roshan
John Roshan
A 33‐year‐old male who underwent surgery for Tetralogy of Fallot presented with atrial flutter. Electrophysiology study revealed concealed entrainment along the mid lateral right atrium with postpacing interval shorter than the tachycardia cycle length. Ablation at this site terminated the tachycardia. The presence of shorter PPI than TCL was due to a large virtual electrode leading to downstream capture of far field tissue. This case demonstrates that sites showing PPI shorter than TCL are in a slow conducting narrow critical isthmus and hence constitute good ablation targets.

2 May 2021 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Closed access
PDF file
AMAnand Manickavasagam
Anand Manickavasagam
SPSirish Chandra Srinath Patloori
Sirish Chandra Srinath Patloori
DCDavid Chase
David Chase
JRJohn Roshan
John Roshan