Jamal Ahmed Cheema

Jamal Ahmed Cheema

Auto-generated profile, based on publicly available information

Jamal Ahmed Cheema

Center for Biomimetic Sensor Science, Nanyang Technological University, 637553, Singapore

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2017 in Journal of Materials Chemistry C
Verified
Journal Article
Closed access
PDF file
MTMeng-Che Tu
Meng-Che Tu
JCJamal Ahmed Cheema
Jamal Ahmed Cheema
UYUmit Hakan Yildiz
Umit Hakan Yildiz
APAlagappan Palaniappan
Alagappan Palaniappan
BLBo Liedberg
Bo Liedberg
The solvatochromic response of polydiacetylene (PDA) in the vapor phase is enabled upon incorporation with matrix polymers such as polyvinylpyrrolidone (PVP), polyethylene glycol (PEG), polyacrylic acid (PAA), and poly-4-vinylpyridine (P4VP).

22 March 2016 in ACS Applied Materials & Interfaces
Verified
Journal Article
Open access
DRDeepa Rajwar
Deepa Rajwar
GAGopal Ammanath
Gopal Ammanath
JCJamal Ahmed Cheema
Jamal Ahmed Cheema
APAlagappan Palaniappan
Alagappan Palaniappan
UYUmit Hakan Yildiz
Umit Hakan Yildiz
BLBo Liedberg
Bo Liedberg
Here we report on the design and synthesis of cationic water-soluble thiophene copolymers as reporters for colorimetric detection of microRNA (miRNA) in human plasma. Poly(3-alkoxythiophene) (PT) polyelectrolytes with controlled ratios of pendant groups such as triethylamine/1-methyl imidazole were synthesized for optimizing interaction with target miRNA sequence (Tseq). Incorporation of specific peptide nucleic acid (PNA) sequences with the cationic polythiophenes yielded distinguishable responses upon formation of fluorescent PT–PNA–Tseq triplex and weakly fluorescent PT–Tseq duplex, thereby enabling selective detection of target miRNA. Unlike homopolymers of PT (hPT), experimental results indicate the possibility of utilizing copolymers of PT (cPT) with appropriate ratios of pendant groups for miRNA assay in complex matrices such as plasma. As an illustration, colorimetric responses were obtained for lung cancer associated miRNA sequence (mir21) in human plasma, with a detection limit of 10 nM, illustrating the feasibility of proposed methodology for clinical applications without involving sophisticated instrumentation. The described methodology therefore possesses high potential for low-cost nucleic acid assays in resource-limited settings.

1 March 2020 in Talanta
Verified
Journal Article
Open access
HAHakan Berk Aydın
Hakan Berk Aydın
JCJamal Ahmed Cheema
Jamal Ahmed Cheema
GAGopal Ammanath
Gopal Ammanath
CTCihan Toklucu
Cihan Toklucu
MYMuge Yucel
Muge Yucel
UYUmit Hakan Yildiz
Umit Hakan Yildiz
Conjugated polyelectrolytes (CPEs) have been widely used as reporters in colorimetric assays targeting nucleic acids. CPEs provide naked eye detection possibility by their superior optical properties however, as concentration of target analytes decrease, trace amounts of nucleic acid typically yield colorimetric responses that are not readily perceivable by naked eye. Herein, we report a pixelated analysis approach for correlating colorimetric responses of CPE with nucleic acid concentrations down to 1 nM, in plasma samples, utilizing a smart phone with an algorithm that can perform analytical testing and data processing. The detection strategy employed relies on conformational transitions between single stranded nucleic acid-cationic CPE duplexes and double stranded nucleic acid-CPE triplexes that yield distinct colorimetric responses for enabling naked eye detection of nucleic acids. Cationic poly[N,N,N-triethyl-3-((4-methylthiophen-3-yl)oxy)propan-1-aminium bromide] is utilized as the CPE reporter deposited on a polyvinylidene fluoride (PVDF) membrane for nucleic acid assay. A smart phone application is developed to capture and digitize the colorimetric response of the individual pixels of the digital images of CPE on the PVDF membrane, followed by an analysis using the algorithm. The proposed pixelated approach enables precise quantification of nucleic acid assay concentrations, thereby eliminating the margin of error involved in conventional methodologies adopted for interpretation of colorimetric responses, for instance, RGB analysis. The obtained results illustrate that a ubiquitous smart phone could be utilized for point of care colorimetric nucleic acids assays in complex matrices without requiring sophisticated software or instrumentation.

5 October 2015 in The Analyst
Verified
Journal Article
Open access
PDF file
PAPalaniappan Alagappan
Palaniappan Alagappan
JCJamal Ahmed Cheema
Jamal Ahmed Cheema
DRDeepa Rajwar
Deepa Rajwar
GAGopal Ammanath
Gopal Ammanath
LXLiu Xiaohu
Liu Xiaohu
BLBo Liedberg
Bo Liedberg
A novel approach for miRNA assay using a cationic polythiophene derivative, poly[3-(3′-N,N,N-triethylamino-1′-propyloxy)-4-methyl-2,5-thiophene hydrobromide] (PT), immobilized on a quartz resonator is proposed. The cationic PT enables capturing of all RNA sequences in the sample matrix via electrostatic interactions, resulting in the formation of PT–RNA duplex structures on quartz resonators. Biotinylated peptide nucleic acid (b-PNA) sequences are subsequently utilized for the RNA assay, upon monitoring the PT–RNA–b-PNA triplex formation. Signal amplification is achieved by anchoring avidin coated nanoparticles to b-PNA in order to yield responses at clinically relevant concentration regimes. Unlike conventional nucleic acid assay methodologies that usually quantify a specific sequence of RNA, the proposed approach enables the assay of any RNA sequence in the sample matrix upon hybridization with a PNA sequence complementary to the RNA of interest. As an illustration, successful detection of mir21, (a miRNA sequence associated with lung cancer) is demonstrated with a limit of detection of 400 pM. Furthermore, precise quantification of mir21 in plasma samples is demonstrated without requiring PCR and sophisticated instrumentation.