The purpose of this work was to familiarize doctors with the methods and significance of serological and cultural diagnostics of H. pylori infection on the example of the test for diagnosing the state of the gastric mucosa «Gastropanel». Blood serum tests were performed for 1057 patients and 122 healthy people aged 18-64 years: pepsinogen I (PG I), pepsinogen II (PG II), gastrin-17 (G-17), basal/stimulated), antibodies (IgGHp) to H. pylori (Biohit Oyj, Finland). The medians of the studied group indicators did not exceed the reference intervals. 398 (34%) patients have negative H. pylori status (IgGHp-). 275 (26%) patients with serum PG I≤70 mcg/ml were identified. The ratio of PG I/II≤3 in 84 (8%), 36 of them (43% of the group PG I/II≤3) - IgGHp-.
Relevance. The widespread adoption of minimally invasive surgical techniques reduces blood loss during surgical procedures. However, conducting mandatory primary blood typing and confirmatory immunohaematological testing (T&S: blood type ABO/Rh and anti-erythrocyte antibody screening) in all patients prior to surgery violates four of the seven quality criteria for medical care as defined by the World Health Organization. Objective. To determine the feasibility of implementing T&S testing and indications for testing prior to minimally invasive procedures. Material and methods. A retrospective analysis of all cases of hospitalization in a third-level institution in 2022—2023 was carried out. Demographic data of patients, information on surgical interventions, and risk factors for blood transfusions were analyzed. The proportion of surgical procedures with and without transfusions was also compared. Based on this information, a T&S assignment management strategy has been developed. Results. The total level of transfusions of blood components is 8%, while surgical patients account for 6%. The risk of transfusion of blood components increases 4-fold when transferred from another medical institution compared with planned hospitalization (odds ratio (OR) 3.65; 95% confidence interval (CI) 2.99—4.46; p<0.05), compared with emergency hospitalization (OR 1.27; 95% CI 1.17—1.38; p<0.05). The number of blood transfusions depends on the age and gender of the patient (p<0.05). The need for transfusion of donor red blood cells increases as hemoglobin levels decrease before surgery. The level of 122 g/l (Sp 72%, Se 67%) is associated with an increased risk (ROC AUCHb=0.76; 95% CI 0.74—0.77; p<0.0001) with a diagnostic accuracy of 87.3%. Thanks to the developed prescription algorithm, the number of T&S procedures decreased by 35% (from 38.000 to 24.000) per 10.000 surgeries, mainly due to reduced screening for anti-erythrocyte antibodies. Thus, the cost of conducting T&S for 10.000 surgeries were halved — from 16 million rubles to 8 million rubles. Conclusions. Only a small proportion of surgical patients require blood transfusions. By eliminating certain clinical indications for T&S tests from routine practice, annual healthcare costs can be significantly reduced.
21 October 2021 in Antibiot Khimioter = Antibiotics and Chemotherapy
Relevance: The two systems for determining the susceptibility of bacteria to antimicrobial drugs, CLSI and EUCAST, are recommended for use in the global system of epidemiological surveillance of antimicrobial resistance of the World Health Organization. However, they differ in the methodology of setting an antimicrobial susceptibility testing, threshold values of cut-off points, as well as interpretation of results. The true significance of methodological differences between these systems for global microbiological monitoring is unclear.The aim of the study was to evaluate the influence of differences in the cut-off points of CLSI and EUCAST on the interpretation of antimicrobial sensitivity of microorganisms to carbapenems in Saint Petersburg.Design: screening and comparative study.Materials and methods. Sensitivity to Meropenem was studied in Escherichia coli (n=2956), as well as Klebsiella pneumoniae (n=1189) for the period of 2011–2013 and 2016–2019, and interpreted according to the threshold values of the two guidelines (2020). Results. The weighted Kappa showed good agreement between the EUCAST vs CLSI standards for both E.coli (0.58; 95% CI 0.55–0.61) and K.pneumoniae (0.77; 0.73–0.81). Mcnemar's Chi-square test revealed differences between the two standards in assessing sensitivity to Meropenem of E.coli which were 5.31% (95% CI 5.06–5.31%, P<0.0001), and of K.pneumoniae — 3.95% (95% CI 3.36–3.95%, P<0.0001).Conclusion. The reliability of determining sensitivity bacteria to anti-microbial drugs has a significant impact on their rational use and the results of microbiological monitoring. The first priority is to develop national standards that take regional characteristics into account.
Background. Timely clinical decision-making regarding interventional management in transplant recipients to preserve allograft function depends on the accuracy of correlating in vitro biomaterial characteristics with native in vivo intermolecular interactions. Aim. To develop a system for short‑term risk stratification and prediction in kidney transplant recipients based on the analysis of functional and morphological pattern dynamics using medical informatics methods. Materials and methods. The analysis included data from 160 kidney transplant recipients comprising a total of 5,531 observations. Current risk assessment was performed using clinically validated in vitro threshold values reflecting allograft function and systemic inflammatory activity. A time‑series analysis model based on Long Short‑Term Memory (LSTM) recurrent neural network was employed for risk category prediction. Results. The predictive system demonstrated high accuracy in short‑term risk classification (approximately 90%) when at least three consecutive days of dynamic monitoring were available. Risk state formation is determined not by isolated deviations of individual parameters, but by coordinated changes in functional and morphological patterns, primarily the most energy‑intensive cyclic ion transport processes and inflammatory markers. Conclusion. The proposed approach may serve as a clinical decision support tool for timely therapy adjustment and allograft function preservation.
17 February 2023 in The Scientific Notes of the Pavlov University
Introduction. The laboratory should have a quality management system for laboratory research. The objective was to analyze the requirements of regulatory documentation related to the accreditation of medical laboratories in the National Accreditation System for compliance with GOST R ISO 15189-2015. Methods and materials. A retrospective analysis of the requirements of national and industry standards related to medical laboratories was carried out. Results. The policy management of the activities of the National Accreditation System is based on strict compliance with the requirements of international rules. The provisions of the regulations of the Ministry of Economic Development are a priority for the Federal Accreditation Service. Applicants must comply not only with GOST R ISO 15189-2015, but also with the accreditation criteria of the National Accreditation System. Failure to comply with the requirements related to the traceability of measurement results, measurement uncertainty during calibrations and rules for registration of protocols, entails refusal of accreditation or suspension of its validity. It is mandatory to provide information on the results of activities, including information on issued reports (protocols) with the attachment of an electronic document «in the form of an electronic image (scanned copy) of the document» using the Federal State Information System, about changes in the composition of its employees and their competence, changes in technical equipment in the field of accreditation, about the temporary absence of an employee. Work experience in the field of employee accreditation needs to be documented. Participation in qualification verification programs in the field of accreditation is a criterion of laboratory competence and confirmation of the reliability of measurement results issued by laboratories. It is important to observe strictly defined deadlines for submitting documents to confirm competence. Submitting an application outside of school hours leads to refusal. Conclusion. It is necessary to recommend participation in voluntary accreditation for laboratories conducting research at the interstate level. It is necessary to form a state policy in the field of quality of laboratory diagnostics based on GOST R ISO 15189-2015 and formulate it in the format of a federal law. The formed chain of metrological traceability should include reference, calibration and routine laboratories. It is necessary to introduce changes and clarifications into the regulatory framework of the National Accreditation System, taking into account the peculiarities of medical laboratories.