Department of Construction, Faculty of Civil Engineering, University of Prishtina, Building of Technical Faculties, Str. Agim Ramadani, 10000 Prishtina, Kosovo
Auto-generated profile, based on publicly available information
Arton D. Dautaj
Department of Construction, Faculty of Civil Engineering, University of Prishtina, Building of Technical Faculties, Str. Agim Ramadani, 10000 Prishtina, Kosovo
This paper describes an experimental programme in which seven reinforced concrete (RC) frames with masonry infill were tested under cyclic lateral loading. Based on the behaviour of the tested units, a new macromodel was developed based on a multi-strut formulation to analyse infilled RC frames. Comparison of the analytical results of the model with experimental data revealed that the proposed model yields a more reasonable lateral strength result than conventional analyses. Furthermore, the model can be used to predict the different failure modes of infilled RC frames, which will be useful for the future analysis and design of infilled RC frames.
6 April 2019 in International Journal of Advanced Structural Engineering
The shear capacity of masonry-infilled reinforced concrete (RC) frames is determined experimentally by testing of five 2/3 scale, one story, one bay infilled RC frame specimens with varying degrees of separation between upper and lower portions of the masonry infill panel. The main premise of this experimental study was to find the contribution of masonry panel in global resistance of infilled RC frames versus shear force. Based on the experimental results, a new method is proposed for the determination of the shear resistance and the contribution of the masonry infill panel is derived. Comparisons of experimental and analytical results show that the proposed method for evaluating the shear resistance of the masonry panels offers a promising approach for the design of infilled RC frames. Furthermore, the results of this study indicate that the shear resistance of masonry panel in infilled RC frames is strongly influenced by the stiffness and lateral resistance of the RC frame.
6 December 2018 in European Journal of Environmental and Civil Engineering
This work examines the potential strengthening effect of glass fibre-reinforced polymers (GFRPs) on masonry infilled reinforced concrete (RC) frames. The experimental investigation is conducted in two stages. Initially, the behaviours of masonry infilled RC frames, including their internal interactions, lateral strength, failure modes (considering both masonry and beam-column joint failures) and ultimate failure mechanism, are characterised using six different test units. The observed behaviours are used to develop a strategy for strengthening of masonry infilled RC frames by the incorporation of GFRPs. The impact of GFRP presence on the behaviour of masonry infilled RC frames is comprehensively evaluated and the performances of GFRP-strengthened and unstrengthened structures are compared. The results demonstrate that the addition of GFRPs increases the lateral strength and stiffness significantly and alters the ultimate failure mechanism of masonry infilled RC frames.
In this study is investigated the performance of different glass fibre-reinforced polymer strengthening schemes on infilled reinforced concrete (RC) frames. The main objective was to limit the damage to beam–column joints and inter-storey drift ratios and to protect RC frames against the negative effects caused by infill-RC frame interaction. Five specimens were tested: one without infill and four infilled with full-scale hollow clay block masonry unit, three of which were strengthened with different schemes. Results showed that the beam–column joints could remain undamaged, lateral strength and stiffness were enhanced, inter-storey drift was limited, and new load carrying systems are generated.