Vishal Rajput

Vishal Rajput

Auto-generated profile, based on publicly available information

Vishal Rajput

PDPM Indian Institute of Information and Technology Design and Manufacturing Jabalpur, Jabalpur, India

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 July 2019 in Multimedia Tools and Applications
Verified
Journal Article
Closed access
PDF file
VRVishal Rajput
Vishal Rajput
IAIrshad Ansari
Irshad Ansari


18 August 2020 in Multimedia Tools and Applications
Verified
Journal Article
Closed access
PDF file
JNJayanthi N.
Jayanthi N.
VRVishal Rajput
Vishal Rajput
SIS. Indu
S. Indu

6 October 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
VRVishal Rajput
Vishal Rajput
Adjoint design sensitivities depend on the constitutive model supplied to the adjoint. Agreement with a finite-difference gradient verifies that derivative. It does not show that every constitutive model still compatible with the measurements supports the same design direction.For steady conduction with a movable heat source, thermal resistance converts the state, the objective, the design gradient, and the curvature into exact moments. The reduction reveals exact decision-equivalence classes of physically distinct conductivity fields. A finite change of resistance splits into an exact linear term and an exact remainder.A discrete conjugate heat-transfer channel has no such reduction. The flux derivative inside the discrete adjoint is analytic. Central differences of the reduced objective match it to 3.1×10⁻¹² at step 10⁻⁵. Sensor and monitor temperatures are interpolated to fixed physical coordinates. The reported quantity is the critical measurement tolerance at which the feasible design gradient reaches zero. On a 96×64 mesh that tolerance is 0.01073 with three wall sensors and 0.01509 when the heated-face temperature of the ambiguous conductivity strip is added. The same ordering holds on 12×8, 24×16, 48×32, and 96×64, as a numerical search to a stated tolerance. On the coarse mesh, a Taylor enclosure with an explicit fourth-derivative remainder puts both signs in the three-sensor feasible set and only the negative sign in the four-sensor set. All channel observations are synthetic temperatures from the nominal discrete model.

30 March 2018
Verified
Book Chapter
Closed access
PDF file
VRVishal Rajput
Vishal Rajput
IAIrshad Ansari
Irshad Ansari
MPMillie Pant
Millie Pant