Rima X. Schüssler

Rima X. Schüssler

Auto-generated profile, based on publicly available information

Rima X. Schüssler

University of Amsterdam

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2020 in Nature
Verified
Journal Article
Closed access
PDF file
RSR. X. Schüssler
R. X. Schüssler
HBHendrik Bekker
Hendrik Bekker
MBM. Braß
M. Braß
HCH. Cakir
H. Cakir
JLJosé R. Crespo López-Urrutia
José R. Crespo López-Urrutia
KBK. Blaum
K. Blaum

13 August 2021 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
PFP. Filianin
P. Filianin
CLChunhai Lyu
Chunhai Lyu
MDM. Door
M. Door
KBK. Blaum
K. Blaum
WHW. J. Huang
W. J. Huang
SES. Eliseev
S. Eliseev
The cyclotron frequency ratio of Os18729+ to Re18729+ ions was measured with the Penning-trap mass spectrometer PENTATRAP. The achieved result of R=1.000 000 013 882(5) is to date the most precise such measurement performed on ions. Furthermore, the total binding-energy difference of the 29 missing electrons in Re and Os was calculated by relativistic multiconfiguration methods, yielding the value of ΔE=53.5(10)  eV. Finally, using the achieved results, the mass difference between neutral Re187 and Os187, i.e., the Q value of the β− decay of Re187, is determined to be 2470.9(13) eV.

22 December 2021 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
MMMatteo Mazzanti
Matteo Mazzanti
RSR. X. Schüssler
R. X. Schüssler
JEJ. D. Arias Espinoza
J. D. Arias Espinoza
ZWZ. Wu
Z. Wu
RGRene Gerritsma
Rene Gerritsma
ASA. Safavi-Naini
A. Safavi-Naini
We propose a new scalable architecture for trapped ion quantum computing that combines optical tweezers delivering qubit state-dependent local potentials with oscillating electric fields. Since the electric field allows for long-range qubit-qubit interactions mediated by the center-of-mass motion of the ion crystal alone, it is inherently scalable to large ion crystals. Furthermore, our proposed scheme does not rely on either ground-state cooling or the Lamb-Dicke approximation. We study the effects of imperfect cooling of the ion crystal, as well as the role of unwanted qubit-motion entanglement, and discuss the prospects of implementing the state-dependent tweezers in the laboratory.

16 March 2020 in Physical Review Letters
Verified
Journal Article
Open access
PDF file
ARA. Rischka
A. Rischka
HCH. Cakir
H. Cakir
MDM. Door
M. Door
PFP. Filianin
P. Filianin
ZHZ. Harman
Z. Harman
KBK. Blaum
K. Blaum
First ever measurements of the ratios of free cyclotron frequencies of heavy, highly charged ions with Z>50 with relative uncertainties close to 10−11 are presented. Such accurate measurements have become realistic due to the construction of the novel cryogenic multi-Penning-trap mass spectrometer PENTATRAP. Based on the measured frequency ratios, the mass differences of five pairs of stable xenon isotopes, ranging from Xe126 to Xe134, have been determined. Moreover, the first direct measurement of an electron binding energy in a heavy highly charged ion, namely of the 37th atomic electron in xenon, with an uncertainty of a few eV is demonstrated. The obtained value agrees with the calculated one using two independent, different implementations of the multiconfiguration Dirac-Hartree-Fock method. PENTATRAP opens the door to future measurements of electron binding energies in highly charged heavy ions for more stringent tests of bound-state quantum electrodynamics in strong electromagnetic fields and for an investigation of the manifestation of light dark matter in isotopic chains of certain chemical elements.

6 July 2021 in Physical Review A
Verified
Journal Article
Closed access
PDF file
JEJ. D. Arias Espinoza
J. D. Arias Espinoza
MMMatteo Mazzanti
Matteo Mazzanti
KFK. Fouka
K. Fouka
RSR. X. Schüssler
R. X. Schüssler
ZWZ. Wu
Z. Wu
ASA. Safavi-Naini
A. Safavi-Naini
We propose a method for generating programmable interactions in one- and two-dimensional trapped-ion quantum simulators. Here we consider the use of optical tweezers to engineer the sound-wave spectrum of trapped ion crystals. We show that this approach allows us to tune the interactions and connectivity of the ion qubits beyond the power-law interactions accessible in current setups. We demonstrate the experimental feasibility of our proposal using realistic tweezer settings and experimentally relevant trap parameters to generate the optimal tweezer patterns to create target spin-spin interaction patterns in both one- and two-dimensional crystals. Our approach will advance quantum simulation in trapped-ion platforms as it allows them to realize a broader family of quantum spin Hamiltonians.

19 April 2024 in Nature Physics
Verified
Journal Article
Open access
PDF file
CSChristoph Schweiger
Christoph Schweiger
MBMartin Braß
Martin Braß
VDVincent Debierre
Vincent Debierre
MDMenno Door
Menno Door
HDHolger Dorrer
Holger Dorrer
KBKlaus Blaum
Klaus Blaum
The investigation of the absolute scale of the effective neutrino mass remains challenging due to the exclusively weak interaction of neutrinos with all known particles in the standard model of particle physics. At present, the most precise and least-model-dependent upper limit on the electron antineutrino mass is set by the Karlsruhe Tritium Neutrino Experiment (KATRIN) from the analysis of the tritium β-decay. Another promising approach is the electron capture in 163Ho, which is under investigation using microcalorimetry by the Electron Capture in Holmium (ECHo) and HOLMES collaborations. An independently measured Q value for this process is vital for the assessment of systematic uncertainties in the neutrino mass determination. Here we report a direct, independent determination of this Q value by measuring the free-space cyclotron frequency ratio of highly charged ions of 163Ho and 163Dy in the Penning-trap experiment PENTATRAP. Combining this ratio with atomic physics calculations of the electronic binding energies yields a Q value of 2,863.2 ± 0.6 eV c−2, which represents a more than 50-fold improvement over the state of the art. This will enable the determination of the electron neutrino mass on a sub-electronvolt level from the analysis of the electron capture in 163Ho.