Damien Delafoy

Damien Delafoy

Auto-generated profile, based on publicly available information

Damien Delafoy

CEA, Centre National de Recherche en Génomique Humaine (CNRGH), Université Paris-Saclay, Evry, 91057, France

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
ALAurélie Leduc
Aurélie Leduc
ABAsmae Bachr
Asmae Bachr
FSFlorian Sandron
Florian Sandron
MDMarc Delépine
Marc Delépine
DDDamien Delafoy
Damien Delafoy
VMVincent Meyer
Vincent Meyer
Background: Short read sequencing technologies have dominated the field of human whole genome sequencing in the past years in terms of cost, throughput, and accuracy. However, thanks to recent technological evolution, long read approaches have become increasingly competitive and complementary to short reads. With the gap in the cost per genome closing slowly between both approaches, long reads might replace short read sequencing in future research and clinical applications. Still, comprehensive evaluation is necessary to conclude on the performance and general advantages of each technology. Results: In this study, we compared the latest chemistries of major suppliers of short and long read technologies: Illumina short reads, Illumina Complete Long Reads (ICLR), Pacific Biosciences HiFi reads (PacBio), and Oxford Nanopore Technologies long reads (ONT). Using the HG002 human reference sample and established bioinformatics guidelines, we assessed their variant calling performance against the latest available truth sets at different levels of coverage. For single nucleotide variant detection, all technologies were equivalent. Despite the latest improvements in chemistry, indel calling with ONT continues to lag in accuracy behind other technologies. In contrast, long reads delivered a clear advantage in structural variant detection, surpassing short reads in both accuracy and sensitivity. The hybrid ICLR approach achieved intermediate performance, narrowing the gap between short and long read sequencing. Furthermore, long reads enhanced haplotype-phasing resolution, enabling the phasing of over 80% of the genome. Conclusions: These findings highlight the specific strengths and limitations of recent sequencing technologies, aiding the decision-making in future research projects, technological platforms development, and clinical applications.

2 October 2021 in bioRxiv
Verified
Preprint
Open access
PDF file
DDDamien Delafoy
Damien Delafoy
JMJonathan Mercier
Jonathan Mercier
ELElise Larsonneur
Elise Larsonneur
NWNicolas Wiart
Nicolas Wiart
FSFlorian Sandron
Florian Sandron
VMVincent Meyer
Vincent Meyer
Background Interest in genomic medicine for human health studies and clinical applications is rapidly increasing. Clinical applications require contamination-free samples to avoid misleading results and provide a sound basis for diagnosis. Results Here we present ContaTester, a tool which requires only allele balance information gathered from a VCF file to detect cross-contamination in germline human DNA samples. Based on a regression model of allele balance distribution, ContaTester allows fast checking of contamination levels for single samples or large cohorts (less than two minutes per sample). We demonstrate the efficiency of ContaTester using experimental validations: ContaTester shows similar results to methods requiring alignment data but with a significantly reduced storage footprint and less computation time. Additionally, for contamination levels above 5%, ContaTester can identify contaminants across a cohort, providing important clues for troubleshooting and quality assessment. Conclusions ContaTester estimates contamination levels from VCF files generated from whole genome sequencing normal sample and provides reliable contaminant identification for cohorts or experimental batches.

26 September 2023 in medRxiv
Verified
Preprint
Open access
PDF file
GSG. El Soufi
G. El Soufi
LJL. Di Jorio
L. Di Jorio
ZGZ. Gerber
Z. Gerber
NCN. Cluzel
N. Cluzel
JAJ. Van Assche
J. Van Assche
CWC. Wallet
C. Wallet
Wastewater-based epidemiology is experiencing exponential development. Despite undeniable advantages compared to patient-centered approaches (cost, anonymity, survey of large populations without bias, detection of asymptomatic infected peoples…), major technical limitations persist. Among them is the low sensitivity of the current methods used for quantifying and sequencing viral genomes from wastewater. In situations of low viral circulation, during initial stages of viral emergences, or in countries experiencing heavy rains, the extremely low concentrations of viruses in wastewater may fall below the limit of detection of the current methods. The availability and cost of the commercial kits, as well as the requirement of expensive materials, can also present major blocks to the development of wastewater-based epidemiological survey, specifically in low-income countries. Thereby, highly sensitive, low cost and open-access methods are still needed to increase the predictability of the viral emergences, to survey low-circulating viruses and to allow wastewater-based surveillance. Here, we outline and characterize new protocols for concentrating, quantifying, monitoring, and sequencing SARS-CoV-2 from large volumes (500 mL-1L) of raw wastewater. Our nucleic acid extraction technique (the routine C: 5ml method) does not require sophisticated equipment such as automatons and is not reliant on commercial kits, making it readily available to a broader range of laboratories for routine epidemiological survey. Furthermore, we demonstrate the efficiency, the repeatability, and the high sensitivity of a new membrane-based concentration method (MBC: 500 mL method) for enveloped (SARS-CoV-2) and naked (FRNAPH GGII) viruses. We show that the MBC method allows the quantification and the monitoring of viruses in wastewater with a significantly improved sensitivity. In contexts of low viral circulation, we report quantifications of SARS-CoV-2 in wastewater at concentrations below 100 genome copies per liter and as low as 40 genome copies per liter. In highly diluted samples collected in wastewater treatment plants of French Guiana, we confirmed the accuracy of the MBC method compared to the estimations done with the C method. Finally, we demonstrate that both the C and MBC methods are compatible with SARS-CoV-2 sequencing. We show that the quality of the sequence is correlated with the concentration of the extracted viral genome. Of note, the quality of the sequences obtained with some MBC processed wastewater was improved by dilutions or enzyme substitutions suggesting the presence of specific enzyme inhibitors in some wastewater. To the best of our knowledge, our MBC method is the first efficient, sensitive, repeatable, and up-scalable method characterized for SARS-CoV-2 quantification and sequencing from large volumes of wastewater. Graphical