Jie Wei

Jie Wei

Auto-generated profile, based on publicly available information

Jie Wei

East China University of Science and Technology

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2012 in International Journal of Nanomedicine
Verified
Journal Article
Open access
PDF file
XLXiaochen Liu
Xiaochen Liu
MZMinzhi Zhao
Minzhi Zhao
JLJingxiong Lu
Jingxiong Lu
JMJian Ma
Jian Ma
JWJie Wei
Jie Wei
SWShicheng Wei
Shicheng Wei
Introduction:Hydroxyapatite (HA) is the principal inorganic constituent of human bone. Due to its good biocompatibility and osteoconductivity, all kinds of HA particles were prepared by different methods. Numerous reports demonstrated that the properties of HA affected its biological effects. Methods: Two kinds of nanohydroxyapatite with different sizes and crystallinities were obtained via a hydrothermal treatment method under different temperatures. It was found that at a temperature of 140°C, a rod-like crystal (n-HA1) with a diameter of 23 ± 5 nm, a length of 47 ± 14 nm, and crystallinity of 85% ± 5% was produced, while at a temperature of 80°C, a rod-like crystal (n-HA2) with a diameter of 16 ± 3 nm, a length of 40 ± 10 nm, and crystallinity of 65% ± 3% was produced. The influence of nanohydroxyapatite size and crystallinity on osteoblast viability was studied by MTT, scanning electron microscopy, and flow cytometry. Results: n-HA1 gave a better biological response than n-HA2 in promoting cell growth and inhibiting cell apoptosis, and also exhibited much more active cell morphology. Alkaline phosphatase activity for both n-HA2 and n-HA1 was obviously higher than for the control, and no significant difference was found between n-HA1 and n-HA2. The same trend was observed on Western blotting for expression of type I collagen and osteopontin. In addition, it was found by transmission electron microscopy that large quantities of n-HA2 entered into the cell and damaged the cellular morphology. Release of tumor necrosis factor alpha from n-HA2 was markedly higher than from n-HA1, indicating that n-HA2 might trigger a severe inflammatory response. Conclusion: This work indicates that not all nanohydroxyapatite should be considered a good biomaterial in future clinical applications.

6 September 2011 in Journal of Materials Science: Materials in Medicine
Verified
Journal Article
Closed access
PDF file
HLHong Li
Hong Li
YYYonggang Yan
Yonggang Yan
JWJie Wei
Jie Wei
JMJian Ma
Jian Ma
MGMin Gong
Min Gong
YZYunfei Zhang
Yunfei Zhang

1 May 2009 in Journal of the American Ceramic Society
Verified
Journal Article
Closed access
PDF file
JWJie Wei
Jie Wei
XWXiaohui Wu
Xiaohui Wu
CLChangsheng Liu
Changsheng Liu
JJJunfeng Jia
Junfeng Jia
SHSu‐Jin Heo
Su‐Jin Heo
JSJung‐Woog Shin
Jung‐Woog Shin

1 May 2014 in International Journal of Nanomedicine
Verified
Journal Article
Open access
XCXingtoa Chen
Xingtoa Chen
GLGuoyue Lv
Guoyue Lv
JZJue Zhang
Jue Zhang
STSongchao Tang
Songchao Tang
YYYonggang Yan
Yonggang Yan
JWJie Wei
Jie Wei
A multi-(amino acid) copolymer (MAC) based on ω-aminocaproic acid, γ-aminobutyric acid, L-alanine, L-lysine, L-glutamate, and hydroxyproline was synthetized, and MAC microspheres encapsulating bovine serum albumin (BSA) were prepared by a double-emulsion solvent extraction method. The experimental results show that various preparation parameters including surfactant ratio of Tween 80 to Span 80, surfactant concentration, benzyl alcohol in the external water phase, and polymer concentration had obvious effects on the particle size, morphology, and encapsulation efficiency of the BSA-loaded microspheres. The sizes of BSA-loaded microspheres ranged from 60.2 µm to 79.7 µm, showing different degrees of porous structure. The encapsulation efficiency of BSA-loaded microspheres also ranged from 38.8% to 50.8%. BSA release from microspheres showed the classic biphasic profile, which was governed by diffusion and polymer erosion. The initial burst release of BSA from microspheres at the first week followed by constant slow release for the next 7 weeks were observed. BSA-loaded microspheres could degrade gradually in phosphate buffered saline buffer with pH value maintained at around 7.1 during 8 weeks incubation, suggesting that microsphere degradation did not cause a dramatic pH drop in phosphate buffered saline buffer because no acidic degradation products were released from the microspheres. Therefore, the MAC microspheres might have great potential as carriers for protein delivery.

1 February 2005 in Journal of Materials Science
Verified
Journal Article
Closed access
PDF file
WJW. Jie
W. Jie
YLYubao Li
Yubao Li
HYH. Yi
H. Yi

1 January 2007 in Chinese Science Bulletin
Verified
Journal Article
Closed access
PDF file
KYKong Yang
Kong Yang
JWJie Wei
Jie Wei
CWChaoYuan Wang
ChaoYuan Wang
YLYuBao Li
YuBao Li