Ehsan Samei

Ehsan Samei

Auto-generated profile, based on publicly available information

Ehsan Samei

Duke University

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 1998 in Medical Physics
Verified
Journal Article
Closed access
ESEhsan Samei
Ehsan Samei
MFMichael J. Flynn
Michael J. Flynn
DRDavid A. Reimann
David A. Reimann

1 January 2010 in Radiology
Verified
Journal Article
Closed access
DMDaniele Marin
Daniele Marin
RNRendon C. Nelson
Rendon C. Nelson
SSSebastian T. Schindera
Sebastian T. Schindera
SRSamuel Richard
Samuel Richard
RYRichard S. Youngblood
Richard S. Youngblood
ESEhsan Samei
Ehsan Samei
Our study results demonstrate that an adaptive statistical iterative reconstruction (ASIR) algorithm yields significantly lower noise and improved image quality at low-tube-voltage (80-kVp), high-tube-current (675-mA) multidetector abdominal CT during the late hepatic arterial phase. PurposeTo investigate whether an adaptive statistical iterative reconstruction (ASIR) algorithm improves the image quality at low-tube-voltage (80-kVp), high-tube-current (675-mA) multidetector abdominal computed tomography (CT) during the late hepatic arterial phase.Materials and MethodsThis prospective, single-center HIPAA-compliant study was institutional review board approved. Informed patient consent was obtained. Ten patients (six men, four women; mean age, 63 years; age range, 51–77 years) known or suspected to have hypervascular liver tumors underwent dual-energy 64-section multidetector CT. High- and low-tube-voltage CT images were acquired sequentially during the late hepatic arterial phase of contrast enhancement. Standard convolution FBP was used to reconstruct 140-kVp (protocol A) and 80-kVp (protocol B) image sets, and ASIR (protocol C) was used to reconstruct 80-kVp image sets. The mean image noise; contrast-to-noise ratio (CNR) relative to muscle for the aorta, liver, and pancreas; and eff...

11 June 2012 in Medical Physics
Verified
Journal Article
Closed access
SRSamuel Richard
Samuel Richard
DHDaniela B. Husarik
Daniela B. Husarik
GYGirijesh Yadava
Girijesh Yadava
SMSimon N. Murphy
Simon N. Murphy
ESEhsan Samei
Ehsan Samei

11 September 2019 in Medical Physics
Verified
Journal Article
Closed access
ESEhsan Samei
Ehsan Samei
DBDonovan Bakalyar
Donovan Bakalyar
KBKirsten L. Boedeker
Kirsten L. Boedeker
SBSamuel Brady
Samuel Brady
JFJiahua Fan
Jiahua Fan
JWJia Wang
Jia Wang

1 April 2005 in Medical Physics
Verified
Journal Article
Open access
PDF file
ESEhsan Samei
Ehsan Samei
ABAldo Badano
Aldo Badano
DCDev Chakraborty
Dev Chakraborty
KCKen Compton
Ken Compton
CCCraig Cornelius
Craig Cornelius
CWCharles E. Willis
Charles E. Willis
Digital imaging provides an effective means to electronically acquire, archive, distribute, and view medical images. Medical imaging display stations are an integral part of these operations. Therefore, it is vitally important to assure that electronic display devices do not compromise image quality and ultimately patient care. The AAPM Task Group 18 (TG18) recently published guidelines and acceptance criteria for acceptance testing and quality control of medical display devices. This paper is an executive summary of the TG18 report. TG18 guidelines include visual, quantitative, and advanced testing methodologies for primary and secondary class display devices. The characteristics, tested in conjunction with specially designed test patterns (i.e., TG18 patterns), include reflection, geometric distortion, luminance, the spatial and angular dependencies of luminance, resolution, noise, glare, chromaticity, and display artifacts. Geometric distortions are evaluated by linear measurements of the TG18‐QC test pattern, which should render distortion coefficients less than 2%/5% for primary/secondary displays, respectively. Reflection measurements include specular and diffuse reflection coefficients from which the maximum allowable ambient lighting is determined such that contrast degradation due to display reflection remains below a 20% limit and the level of ambient luminance does not unduly compromise luminance ratio (LR) and contrast at low luminance levels. Luminance evaluation relies on visual assessment of low contrast features in the TG18‐CT and TG18‐MP test patterns, or quantitative measurements at 18 distinct luminance levels of the TG18‐LN test patterns. The major acceptable criteria for primary/secondary displays are maximum luminance of greater than , LR of greater than , and contrast conformance to that of the grayscale standard display function (GSDF) of better than , respectively. The angular response is tested to ascertain the viewing cone within which contrast conformance to the GSDF is better than and LR is greater than for primary/secondary displays, or alternatively, within which the on‐axis contrast thresholds of the TG18‐CT test pattern remain discernible. The evaluation of luminance spatial uniformity at two distinct luminance levels across the display faceplate using TG18‐UNL test patterns should yield nonuniformity coefficients smaller than 30%. The resolution evaluation includes the visual scoring of the CX test target in the TG18‐QC or TG18‐CX test patterns, which should yield scores greater than for primary/secondary displays. Noise evaluation includes visual evaluation of the contrast threshold in the TG18‐AFC test pattern, which should yield a minimum of targets visible for primary/secondary displays. The guidelines also include methodologies for more quantitative resolution and noise measurements based on MTF and NPS analyses. The display glare test, based on the visibility of the low‐contrast targets of the TG18‐GV test pattern or the measurement of the glare ratio (GR), is expected to yield scores greater than and GRs greater than for primary/secondary displays. Chromaticity, measured across a display faceplate or between two display devices, is expected to render a , color separation of less than 0.01 for primary displays. The report offers further descriptions of prior standardization efforts, current display technologies, testing prerequisites, streamlined procedures and timelines, and TG18 test patterns.

1 August 2012 in Radiology
Verified
Journal Article
Closed access
CMCynthia H. McCollough
Cynthia H. McCollough
GCGuang Hong Chen
Guang Hong Chen
WKWilli Kalender
Willi Kalender
SLShuai Leng
Shuai Leng
ESEhsan Samei
Ehsan Samei
RPRoderic I. Pettigrew
Roderic I. Pettigrew
This report summarizes the advances in data acquisition, image reconstruction, and optimization processes that were identified by consensus as being necessary to achieve effective dose levels for r... This Special Report presents the consensus of the Summit on Management of Radiation Dose in Computed Tomography (CT) (held in February 2011), which brought together participants from academia, clin...