Aaron Mascaro

Aaron Mascaro

Auto-generated profile, based on publicly available information

Aaron Mascaro

Department of Physics, McGill University, Montreal, QC H3A 2T8, Canada

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2017 in Nano Letters
Verified
Journal Article
Closed access
AMAaron Mascaro
Aaron Mascaro
ZWZi Wang
Zi Wang
PHPierre Hovington
Pierre Hovington
YMYoichi Miyahara
Yoichi Miyahara
APAndrea Paolella
Andrea Paolella
PGPeter Grutter
Peter Grutter

1 March 2019 in Beilstein Journal of Nanotechnology
Verified
Journal Article
Open access
PDF file
AMAaron Mascaro
Aaron Mascaro
YMYoichi Miyahara
Yoichi Miyahara
TETyler Enright
Tyler Enright
ODOmur E Dagdeviren
Omur E Dagdeviren
PGPeter Grutter
Peter Grutter
Recently, there have been a number of variations of electrostatic force microscopy (EFM) that allow for the measurement of time-varying forces arising from phenomena such as ion transport in battery materials or charge separation in photovoltaic systems. These forces reveal information about dynamic processes happening over nanometer length scales due to the nanometer-sized probe tips used in atomic force microscopy. Here, we review in detail several time-resolved EFM techniques based on non-contact atomic force microscopy, elaborating on their specific limitations and challenges. We also introduce a new experimental technique that can resolve time-varying signals well below the oscillation period of the cantilever and compare and contrast it with those previously established.

30 July 2018 in Ophthalmic Epidemiology
Verified
Journal Article
Closed access
ASAndrew F. Smith
Andrew F. Smith
GNGuy Negretti
Guy Negretti
AMAaron Mascaro
Aaron Mascaro
DBDesta Bokre
Desta Bokre
HBHelen Baker
Helen Baker
IMIan E. Murdoch
Ian E. Murdoch
A review of the effectiveness, costs, and cost-effectiveness of detection and treatment strategies for glaucoma control in Sub-Saharan Africa (SSA) was conducted. Detailed searches were performed using the Ovid Medline, Ovid Embase, The Cochrane Library, Web of Science, Scopus, and LILACS databases up to September 2016. The key Medical Subject Heading search terms used included glaucoma, diagnosis, treatment, effectiveness, costs, cost-effectiveness, and Sub-Saharan Africa. Effectiveness was measured as the proportion of study participants with an intra-ocular pressure less than or equal to 22 mmHg. A total of 5658 records were examined with 48 papers identified. The sensitivity and specificity of portable instruments or smartphone technologies to detect glaucomatous changes ranged from 58.3% to 93.8% and from 82.4% to 96.8%, respectively. The overall effect size for various glaucoma interventions was: 0.39 (95% confidence interval (CI) 0.27-0.54, I2 = 64.85, p = 0.036) for laser trabeculoplasty; 0.56 (95% CI 0.23-0.84, I2 = 85.74, p = 0.001) for drainage implant devices; 0.66 (95% CI 0.61-0.71, I2 = 0.00, p = 0.402) for medical management; and 0.73 (95% CI 0.65-0.80, I2 = 93.25, p = 0.000) for all other non-drainage tube surgical interventions, including trabeculectomy surgery and the use of anti-metabolites. The mean annual cost of anti-glaucoma drugs across SSA was USD 394, with a mean direct non-medication cost per year of USD 54, and a mean surgical cost per year of USD 283. While effective glaucoma control interventions exist, their widespread use and diffusion across SSA remain challenging principally due to low per capita income levels and high glaucoma treatment costs.

1 January 2019 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
ODOmur E. Dagdeviren
Omur E. Dagdeviren
YMYoichi Miyahara
Yoichi Miyahara
AMAaron Mascaro
Aaron Mascaro
PGPeter Grütter
Peter Grütter
Atomic force microscopy (AFM) is an analytical surface characterization tool which can reveal a sample’s topography with high spatial resolution while simultaneously probing tip-sample interactions. Local measurement of chemical properties with high-resolution has gained much popularity in recent years with advances in dynamic AFM methodologies. A calibration factor is required to convert the electrical readout to a mechanical oscillation amplitude in order to extract quantitative information about the surface. We propose a new calibration technique for the oscillation amplitude of electrically driven probes using the principle of energy balance. Our technique relies on the measurement of the energy input to maintain the oscillation amplitude constant. With the measurement of the energy input to the probe, a mechanical oscillation amplitude is calculated and a calibration factor to convert the electrical readout in volts to a mechanical oscillation amplitude in Ångströms is obtained. We demonstrate the application of the new technique with a quartz tuning fork including the qPlus configuration, while the same principle can be applied to other piezoelectric resonators such as length extension resonators or piezoelectric cantilevers. The calibration factor obtained by this technique is found to be in agreement with using the thermal noise spectrum method for capsulated and decapsulated tuning forks and tuning forks in the qPlus configuration.

17 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ODOmur Dagdeviren
Omur Dagdeviren
YMYoichi Miyahara
Yoichi Miyahara
AMAaron Mascaro
Aaron Mascaro
TETyler Enright
Tyler Enright
PGPeter Grutter
Peter Grutter
With recent advances in scanning probe microscopy (SPM), it is now routine to determine the atomic structure of surfaces and molecules while quantifying the local tip-sample interaction potentials. Such quantitative experiments using noncontact frequency modulation atomic force microscopy is based on the accurate measurement of the resonance frequency shift due to the tip-sample interaction. Here, we experimentally show that the resonance frequency of oscillating probes used for SPM experiments change systematically as a function of oscillation amplitude under typical operating conditions. This change in resonance frequency is not due to tip-sample interactions, but rather due to the cantilever strain or geometric effects and thus the resonance frequency is a function of the oscillation amplitude. Our numerical calculations demonstrate that the amplitude dependence of the resonance frequency is an additional yet overlooked systematic error source that can result in nonnegligible errors in measured interaction potentials and forces. Our experimental results and complementary numerical calculations reveal that the frequency shift due to this amplitude dependence needs to be corrected even for experiments with active oscillation amplitude control to be able to quantify the tip-sample interaction potentials and forces with milli-electron volt and pico-Newton resolutions.

3 December 2018 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
AMAaron Mascaro
Aaron Mascaro
YMYoichi Miyahara
Yoichi Miyahara
ODOmur E. Dagdeviren
Omur E. Dagdeviren
PGPeter Grütter
Peter Grütter
A common use of atomic force microscopy is quantifying local forces through tip-sample interactions between the probe tip and a sample surface. The accuracy of these measurements depends on the accuracy to which the cantilever spring constant is known. Recent work has demonstrated that the measured spring constant of a cantilever can vary up to a factor of five, even for the exact same cantilever measured by different users on different microscopes. Here, we demonstrate that a standard method for calibrating the spring constant (using oscillations due to thermal energy) is susceptible to ambient acoustic noise, which can alter the result significantly. We demonstrate a step-by-step method to measure the spring constant by actively driving the cantilever to measure the resonance frequency and the quality factor, giving results that are unaffected by acoustic noise. Our method can be performed rapidly on any atomic force microscope without any expensive additional hardware.