Hideo Sugane

Hideo Sugane

Auto-generated profile, based on publicly available information

Hideo Sugane

SUPERCONDUCTING TECHNOLOGY CENTER, SWCC Showa Cable System Co Ltd, 358463 Sagamihara, Kanagawa Japan

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2018 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
KAKazuhisa Adachi
Kazuhisa Adachi
KSKei Shiohara
Kei Shiohara
HSHideo Sugane
Hideo Sugane
TKTasuku Kitamura
Tasuku Kitamura
NMNoubuhiro Mido
Noubuhiro Mido
MIMasataka Iwakuma
Masataka Iwakuma
For the power line between a power generator and a step-up transformer, Isolated Power Bus (IPB) is generally used. The present IPB has a normal cylindrical conductor made of aluminum or copper at the center of the outer jacket and generates very huge Joule loss. To decrease it, superconducting buses have been developing. In this study, a 22 kV-3 kA triaxial superconducting bus was designed and fabricated with YBa2Cu3O7-d (YBCO) tapes and the various kinds of properties were investigated. Previously the AC and lightning impulse withstand voltage test, critical current (Ic) test, and AC loss measurement were conducted and it was shown that the developed triaxial superconducting cable met the designed specifications. In this paper, a sudden short-circuit test of a 2 m-long triaxial cable was carried out by using a 200 MVA short circuit generator. For protection, each phase of the cable was connected to a XLPE cable with a length of 3 m and a cross-sectional area of 250 mm2 in parallel. Three-phase short circuit current of 25 kA was applied to every phase of the cable bathcooled with liquid nitrogen at 77 K for 2 seconds. As a result, the following tremendous phenomenon was demonstrated. Any phase of the triaxial cable kept a flux-flow state and did not quench. Short circuit current was shared between the superconducting cable and the connected XLPE cable, and the branch current ratio varied even during one period of 60 Hz. The numerical simulation was also conducted to explain the phenomenon theoretically. That should contribute to the instantaneous recovery to a normal operation after a short-period interrupt of the circuit

14 February 2017 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
KAKazuhisa Adachi
Kazuhisa Adachi
HSHideo Sugane
Hideo Sugane
TWTianlong Wang
Tianlong Wang
HOHiroki Ohnishi
Hiroki Ohnishi
SSShigeki Sano
Shigeki Sano
MIMasataka Iwakuma
Masataka Iwakuma
When conventional power cables are replaced with superconducting ones, it is necessary to realize a large transmission capacity with a low heat-road from an economic standpoint. In this regard, the isolation power bus (IPB), which is used to connect a generator to a step-up transformer in power plants, is one of the potential candidates to achieve this. We have been developing a 22 kV class triaxial superconducting bus as an alternative to the IPB in which Y1Ba2Cu3O7-d (YBCO) tapes are used, and we have already reported a basic design [1]. In this study, we fabricated 22 kV-3 kA class test cables and terminations to verify the design and investigate the properties of the system. A 7-m-long superconducting test cable was manufactured by using industrial winding machines and critical current Ic values, and voltage withstand tests were performed. The Ic value of each phase was 4 kA or more at 77 K, which was almost equal to the value of the design. In addition, the withstand voltage was higher than the AC withstand voltage of 50 kV and the lightning impulse of 125 kV. Further, thermal loss to the cryogenic region from the cable and terminations was calculated, and the flow pattern and the pressure loss of liquid nitrogen in a 100-m-long cable were simulated by using FLUENT simulation software. The cryogenic system could be designed based on the simulation. The termination design was the most difficult because heat insulation and dielectric insulation for a high voltage had to be realized. We tested various kinds of heat insulation techniques with several vacuum levels to develop an appropriate design.