The objective of this study was to compare single-needle arthrocentesis with distension of the upper compartment of the temporomandibular joint (TMJ) with the conventional two-needle arthrocentesis. Twenty-six patients with articular disc displacement without reduction (DDWOR) were included in the study and assigned to two groups (): single-needle arthrocentesis with distension of the upper compartment of the TMJ (1N) and conventional two-needle arthrocentesis (2N). The maximum interincisal distance (MID) and TMJ pain as measured by the visual analog scale (VAS) were compared. MID and VAS data were obtained: before (T1), seven days after (T2), fifteen days after (T3), one month after (T4), three months after (T5), six months after (T6), nine months after (T7), and one year after the arthrocentesis procedures (T8). Considering each group individually, results of the VAS scores and MID measurements showed a significant difference between T1 and T2–T8 () in both groups. Between two groups, results show no significant differences (). Both techniques tested were effective in reducing pain and increasing MID. Due to the advantages over the conventional two-needle arthrocentesis, single-needle arthrocentesis with distension of the upper compartment should be considered as the first treatment option for patients with painful hypomobilized TMJ of DDWOR.
Aim: The aim of this study is to assess the accuracy of images acquired with cone-beam computed tomography (CBCT) in the identification of three different root alterations. Materials and Methods: Forty human premolars were allocated to four experimental groups (n = 10): sound teeth (control), vertical root fracture (VRF), external root resorption (ERR), and root perforation (RP). After the root alterations had been produced, four teeth were randomly assembled into 10 macerated mandibles and submitted to CBCT. Images were acquired with five voxel sizes (0.125, 0.200, 0.250, 0.300, and 0.400 mm) and assessed by three experienced dental radiologists. Sensitivity, specificity, positive and negative predictive values, and the areas under the receiver operating characteristic curve (accuracy) were calculated. The accuracy of imaging in different voxel sizes was compared with Tukey exact binomial test (α=5%). Results: Accuracy with voxel sizes 0.125, 0.200, and 0.250 mm was significantly higher in the detection of ERRs and VRFs than voxel sizes 0.300 and 0.400 mm. No statistical difference was found in terms of accuracy among any of the studied voxel sizes in the identification of RPs. Conclusions: Voxel size 0.125 mm produced images with the best resolution without increasing radiation levels to the patient when compared to voxel sizes 0.200 and 0.250 mm. Voxel sizes 0.300 and 0.400 mm should be avoided in the identification of root alterations.
1 February 2021 in Journal of Cranio-Maxillofacial Surgery