The current focus on networking and mutual assistance in the management of radiation accidents or incidents has demonstrated the importance of a joined-up approach in physical and biological dosimetry. To this end, the European Radiation Dosimetry Working Group 10 on ‘Retrospective Dosimetry’ has been set up by individuals from a wide range of disciplines across Europe. Here, established and emerging dosimetry methods are reviewed, which can be used immediately and retrospectively following external ionising radiation exposure. Endpoints and assays include dicentrics, translocations, premature chromosome condensation, micronuclei, somatic mutations, gene expression, electron paramagnetic resonance, thermoluminescence, optically stimulated luminescence, neutron activation, haematology, protein biomarkers and analytical dose reconstruction. Individual characteristics of these techniques, their limitations and potential for further development are reviewed, and their usefulness in specific exposure scenarios is discussed. Whilst no single technique fulfils the criteria of an ideal dosemeter, an integrated approach using multiple techniques tailored to the exposure scenario can cover most requirements.
Rapid biodosimetry tools are required to assist with triage in the case of a large-scale radiation incident. Here, we aimed to determine the dose-assessment accuracy of the well-established dicentric chromosome assay (DCA) and cytokinesis-block micronucleus assay (CBMN) in comparison to the emerging γ-H2AX foci and gene expression assays for triage mode biodosimetry and radiation injury assessment. Coded blood samples exposed to 10 X-ray doses (240 kVp, 1 Gy/min) of up to 6.4 Gy were sent to participants for dose estimation. Report times were documented for each laboratory and assay. The mean absolute difference (MAD) of estimated doses relative to the true doses was calculated. We also merged doses into binary dose categories of clinical relevance and examined accuracy, sensitivity and specificity of the assays. Dose estimates were reported by the first laboratories within 0.3–0.4 days of receipt of samples for the γ-H2AX and gene expression assays compared to 2.4 and 4 days for the DCA and CBMN assays, respectively. Irrespective of the assay we found a 2.5–4-fold variation of interlaboratory accuracy per assay and lowest MAD values for the DCA assay (0.16 Gy) followed by CBMN (0.34 Gy), gene expression (0.34 Gy) and γ-H2AX (0.45 Gy) foci assay. Binary categories of dose estimates could be discriminated with equal efficiency for all assays, but at doses ≥1.5 Gy a 10% decrease in efficiency was observed for the foci assay, which was still comparable to the CBMN assay. In conclusion, the DCA has been confirmed as the gold standard biodosimetry method, but in situations where speed and throughput are more important than ultimate accuracy, the emerging rapid molecular assays have the potential to become useful triage tools.
This interlaboratory comparison validates the dicentric chromosome assay for assessing radiation dose in mass casualty accidents and identifies the advantages and limitations of an international biodosimetry network. The assay's validity and accuracy were determined among five laboratories following the International Organization for Standardization guidelines. Blood samples irradiated at the Armed Forces Radiobiology Research Institute were shipped to all laboratories, which constructed individual radiation calibration curves and assessed the dose to dose-blinded samples. Each laboratory constructed a dose-effect calibration curve for the yield of dicentrics for (60)Co gamma rays in the 0 to 5-Gy range, using the maximum likelihood linear-quadratic model, Y = c + alphaD + betaD(2). For all laboratories, the estimated coefficients of the fitted curves were within the 99.7% confidence intervals (CIs), but the observed dicentric yields differed. When each laboratory assessed radiation doses to four dose-blinded blood samples by comparing the observed dicentric yield with the laboratory's own calibration curve, the estimates were accurate in all laboratories at all doses. For all laboratories, actual doses were within the 99.75% CI for the assessed dose. Across the dose range, the error in the estimated doses, compared to the physical doses, ranged from 15% underestimation to 15% overestimation.
The World Health Organization (WHO) held a consultation meeting at WHO Headquarters, Geneva, Switzerland, December 17-18, 2007, to develop the framework for a global biodosimetry network. The WHO network is envisioned to enable dose assessment using multiple methods [cytogenetics, electron paramagnetic resonance (EPR), radionuclide bioassays, etc.]; however, the initial discussion focused on the cytogenetic bioassay (i.e., metaphase-spread dicentric assay). Few regional cytogenetic biodosimetry networks have been established so far. The roles and resources available from United Nations (UN) agencies that provide international cooperation in biological dosimetry after radiological emergencies were reviewed. In addition, extensive reliance on the use of the relevant International Standards Organization (ISO) standards was emphasized. The results of a WHO survey of global cytogenetic biological dosimetry capability were reported, and while the survey indicates robust global capability, there was also a clear lack of global leadership and coordination. The expert group, which had a concentrated focus on cytogenetic biodosimetry, formulated the general scope and concept of operations for the development of a WHO global biodosimetry laboratory network for radiation emergencies (BioDoseNet). Follow-on meetings are planned to further develop technical details for this network.
The aim of biological dosimetry is to estimate the dose and the associated uncertainty to which an accident victim was exposed. This process requires the use of the maximum-likelihood method for fitting a calibration curve, a procedure that is not implemented in most statistical computer programs. Several laboratories have produced their own programs, but these are frequently not user-friendly and not available to outside users. We developed a software for fitting a linear-quadratic dose–response relationship by the method of maximum-likelihood and for estimating a dose from the number of aberrations observed. The program called as CABAS consists of the main curve-fitting and dose estimating module and modules for calculating the dose in cases of partial body exposure, for estimating the minimum number of cells necessary to detect a given dose of radiation and for calculating the dose in the case of a protracted exposure. The program is freely available at http://www.pu.kielce.pl/ibiol/cabas.