Wenbin Liu

Wenbin Liu

Auto-generated profile, based on publicly available information

Wenbin Liu

Institute of Plasma Physics, Hefei institutes of Physical Science, Chinese Academy of Sciences, Hefei 230031, China

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
WLWenbin Liu
Wenbin Liu
YCYihang Chen
Yihang Chen
RKRui Ke
Rui Ke
GMGeorge McKee
George McKee
ZYZheng Yan
Zheng Yan
GTGeorge R. Tynan
George R. Tynan
Theory and simulation suggest the existence of an E   × B staircase in the plasma core consisting of a series of nested m/n = 0/0 E × B shear layers that regulate turbulent transport across the layers together with mesoscale transport events occurring between them. Here, we show evidence for these phenomena in HL-2A L-mode discharges. Both high resolution electron cyclotron emission T e profiles and frequency modulated continuous wave reflectometer n e profiles show multiple gradient corrugations. The analysis of simultaneous poloidally and radially separated beam emission spectroscopy turbulent density fluctuation measurements over most of the minor radius of the plasma provides the evidence of eddy tilting and propagation direction reversals largely coincident with the profile corrugations, with long-range transport events occurring between these locations. The results provide significant additional evidence for the existence of an E × B staircase that influences particle and heat transport in L-mode discharges.

28 June 2002 in The Journal of Physical Chemistry A
Verified
Journal Article
Closed access
RWRobert H. Wood
Robert H. Wood
WLWenbin Liu
Wenbin Liu
DDDouglas J. Doren
Douglas J. Doren

1 August 2015 in Review of Scientific Instruments
Verified
Journal Article
Closed access
XYXiao Yu
Xiao Yu
JSJie Shen
Jie Shen
MQMiao Qu
Miao Qu
WLWenbin Liu
Wenbin Liu
HZHaowen Zhong
Haowen Zhong
XLXiaoyun Le
Xiaoyun Le
Infrared imaging diagnostic method for two-dimensional calorimetric diagnostics has been developed for intense pulsed electron beam (IPEB). By using a 100-μm-thick tungsten film as the infrared heat sink for IPEB, the emitting uniformity of the electron source can be analyzed to evaluate the efficiency and stability of the diode system. Two-dimensional axisymmetric finite element method heat transfer simulation, combined with Monte Carlo calculation, was performed for error estimation and optimization of the method. The test of the method was finished with IPEB generated by explosive emission electron diode with pulse duration (FWHM) of 80 ns, electron energy up to 450 keV, and a total beam current of over 1 kA. The results showed that it is possible to measure the cross-sectional energy density distribution of IPEB with energy sensitivity of 0.1 J/cm2 and spatial resolution of 1 mm. The technical details, such as irradiation protection of bremsstrahlung γ photons and the functional extensibility of the method were discussed in this work.

13 May 2024 in Nuclear Fusion
Verified
Journal Article
Open access
RCRunze Chen
Runze Chen
WLWenbin Liu
Wenbin Liu
JQJinping Qian
Jinping Qian
BZBin Zhang
Bin Zhang
HSHongjuan Sun
Hongjuan Sun
XGXianzu Gong
Xianzu Gong
Experimental research on the electron cyclotron wave (ECW) pre-ionization and assisted start-up was carried out systematically for the first time in EAST tokamak, which is a superconducting device with ITER-like full metal wall. Breakdown and plasma initiation at low toroidal electric fields (<0.3 V m−1) with ECW pre-ionization and startup assistance has been demonstrated. Also, the parameter domain of breakdown is significantly extended towards higher prefill gas pressure. The effect of ECW injection timing, power, toroidal injection angle on breakdown were also investigated. Injecting ECW earlier leads to an earlier breakdown and a higher plasma current ramp rate. The electron cyclotron heating (ECH) power threshold for breakdown in EAST is approximately 0.4 MW. In the range of ECH power tested in this work, higher ECH power is advantageous for achieving earlier and faster breakdown. Furthermore, the breakdown with radial ECW injection occurs earlier compared with oblique injections (co-current and counter-current). During the ECW-assisted startup, the process of burn-through is prolonged by the higher pre-filled gas pressure even though it enhances the ease of breakdown. In addition, compared to the low hybrid wave assistance, the ECW assistance has an effect in averting the generation of runaway electrons and improving the safety of device during startup. Moreover, the ECW assistance exhibits a high tolerance to the impurity and thus ensures a high ramp rate of plasma current even with a high impurity level.

1 May 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
ZCZhengbo Cheng
Zhengbo Cheng
YTYi Tan
Yi Tan
ZGZhe Gao
Zhe Gao
SWShouzhi Wang
Shouzhi Wang
BWBinbin Wang
Binbin Wang
WLWenbin Liu
Wenbin Liu
Since the major/minor radius of the Sino-United Spherical Tokamak (SUNIST) is 0.3/0.23 m, respectively, the space left for magnetic diagnostics in the high field side (HFS) is quite limited. At the same time, a good signal-to-noise ratio and a high-frequency response (up to 1 MHz) are required for equilibrium reconstruction (ER) and Alfven eigenmode studies. Such a magnetic probe array must be extremely thin and tightly close to the central column, not exceeding the inner limiter and leaving the aspect ratio of the spherical tokamak unchanged. Therefore, the turn number and the shape of windings should be highly optimized to enable both a high-frequency response and an enough effective area. A 32-channel magnetic probe array fulfilling these requirements on the central column is designed, calibrated, and installed in the SUNIST. The array consists of 16 probes. Each of them consists of two perpendicular windings, which can measure toroidal and poloidal magnetic fields simultaneously. The effective area and frequency response of each probe are calibrated using a Helmholtz coil and an LCR bridge based on an equivalent probe-and-cable circuit model. After that, an expression of the magnetic diagnostic response to the field coil currents is used to calibrate the installation error. With the full coverage of magnetic probes in the poloidal direction, more reliable ER can be obtained, and the features of magnetohydrodynamic activities in the HFS can be studied.

21 January 2024 in Fusion Engineering and Design
Verified
Journal Article
Closed access
YTY. Tao
Y. Tao
MLMiaohui LI
Miaohui LI
JQJ.P. Qian
J.P. Qian
DMD. Moreau
D. Moreau
BZB. Zhang
B. Zhang
YHY.F. He
Y.F. He